§ 28-447 — Design and installation: Minimum requirements
Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 28-447
Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/2327cc20-f71f-493f-bce5-632f85a72f0b
Sec. 28-447. - Design and installation: Minimum requirements.
(a) No irrigation design or installation shall require the use of any component, including the water meter, in a way that exceeds the manufacturer's published performance limitations for the component. (b) Spacing. (1) The maximum spacing between emission devices must not exceed the manufacturer's published radius or spacing of the emission devices. The proper radius or spacing is determined by referring to the manufacturer's published specifications for a specific emission device at a specific operating pressure. (2) Irrigation systems shall not utilize above-ground spray emission devices in landscapes that are: (i) less than forty-eight (48) inches not including the impervious surfaces in either length or width; or (ii) that have sidewalks, driveways, or streets on two (2) or more sides. If pop-up sprays or rotary sprinkler heads are used in an irrigation system, the sprinkler heads must direct flow away from adjacent surfaces and shall not be installed closer than four (4) inches from a hardscape (for example, and without limitation, a building foundation, fence, concrete, asphalt, pavers, or stones set with mortar. (3) Narrow paved walkways, jogging paths, golf cart paths, or other small areas located in cemeteries, parks, golf courses, or other public areas are exempted from this subsection (b)(3) if runoff from the irrigation system drains into a landscaped area. (c) Emission devices must be installed to operate between the minimum and the maximum sprinkler head pressure as published by the manufacturer for the nozzle and head spacing used. Methods to achieve the water pressure requirements include, but are not limited to, flow control valves, a pressure regulator, or pressure compensating spray heads. (d) Irrigation systems shall have separate zones based on plant type, microclimate factors (such as shade), topographic features (such as slope or elevation), type of soil, and the hydrological requirements of plant types. All emission devices in a zone should irrigate at the same precipitation rate. (e) An irrigator must determine the appropriate length of time to run an irrigation system based on head selection and spacing. The irrigator must also consider the soil's infiltration rate to make sure the irrigation system is operating efficiently to conserve water. (f) Water may not be sprayed over impervious surfaces including, but not limited to, concrete, asphalt, brick, wood, stones set with mortar, walls, fences, sidewalks, and streets. (g) If a master valve is provided, it must be installed on the discharge side of the backflow prevention assembly. (h) All new irrigation systems that are installed using PVC pipe and fittings shall be installed in accordance with the IPC. (i) All new automatically controlled irrigation systems must include sensors or other technology designed to inhibit or interrupt operation of the irrigation system during periods of moisture or rainfall. Rain or moisture shut-off technology must be installed according to the manufacturer's published recommendations. Repairs to existing automatic irrigation systems that require replacement of an existing controller must include a sensor or other technology designed to inhibit or interrupt operation of the irrigation system during periods of moisture or rainfall. (j) All new irrigation systems must include an isolation valve between the water meter and the backflow prevention assembly. (k) Piping. Piping in all irrigation systems must be installed according to the manufacturer's published specifications for depth of pipe coverage. (1) If the manufacturer has not published specifications, the pipe must be buried at least six (6) inches deep and it must be covered with six (6) inches of select backfill between its top and the natural grade of the topsoil. (2) Mounding with select backfill may be employed if the area being irrigated is rock but, if mounding is used, that fact must be noted on the irrigation plan and any safety issues must be addressed with the owner. (3) If utilities, manmade structures, or roots create an unavoidable obstacle that makes the six-inch depth coverage requirement impractical, the piping shall be installed to provide a minimum of two (2) inches of select backfill between the top of the pipe and the natural grade of the topsoil. (4) All trenches and holes created during installation of an irrigation system must be backfilled and compacted to the original grade. (5) The velocity of water through PVC pipe in an irrigation system may not exceed five (5) feet per second. The wiring used to connect an automatic controller to any electrical components must be listed by Underwriters Laboratories as acceptable for burial. The wiring connected to an irrigation system must be sized according to the manufacturer's recommendations. Electrical splices that may be exposed to moisture must be waterproofed as certified by the wire-splice manufacturer. (l) Underground electrical wire used in an irrigation system must be buried with at least six (6) inches of select backfill. (m) Connections to an irrigation system for drinking or domestic use (for example, and without limitation, filling a swimming pool or decorative fountain) are prohibited. If a hose bib (an outdoor water faucet that has hose threads on the spout) is connected to an irrigation system for the purpose of providing supplemental water to an area, the hose bib must be installed using a quick coupler key on a quick coupler installed in a covered, purple valve box . The hose bib and any hoses connected to it must be labeled "non-potable, not safe for drinking." An isolation valve must be installed upstream of a quick coupler connecting a hose bib to an irrigation system. (n) Either a licensed irrigator or an irrigation technician must be on-site during the installation of an irrigation system, unless the irrigation system is being installed by a person exempted under section 28-442 of the Code of the City of Denton, Texas. (o) All irrigation systems must be designed, installed, and operated in a manner that promotes water conservation.
(Ord. No. 26-270, § 2(Exh. A), 3-24-26)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.