Sec. 49-1548. - Standards for methods, devices and assemblies to control cross-connections.
All backflow devices and assemblies shall conform to section 49-803. (a) Air gap: (1) To be considered an air gap, potable and non-potable water shall be separated with a vertical distance between the supply fitting outlet and the highest possible water level of a receptor, or fixture when flooded. The vertical separation shall be at least twice the diameter of the water supply outlet, but never less than one inch. (2) A water supply pipe cut on a diagonal must have a required air gap as measured from the midpoint of the cut to the top of the flood rim. (3) When the water inlet is near a side wall and the horizontal distance from the wall and the supply opening is less than four times the opening, the air gap shall be three times the opening, but not less than one inch. (b) Atmospheric vacuum breakers (AVB) shall be subject to the following: (1) Shall be used against backflow caused by backsiphonage only. (2) May be used for either low health hazard or high health hazard installations. (3) Cannot be under constant residual pressure for more than 12 hours. (4) The AVB must be installed at least six inches above the flood rim of the fixture or downstream piping. (5) No valves are allowed on the downstream piping. (6) Must be installed vertically. (c) Outlets with hose threads shall be equipped to protect the potable water system from contamination. Valve outlets, hose bibs, sill cocks or fixtures with hose attachments which may constitute a cross connection shall be equipped with a tamper-proof vacuum breaker. Sill cocks shall be equipped with an integral vacuum breaker. Exception: Hose bibs dedicated for residential clothes washers and the drain on a water heater. (d) Pressure vacuum breakers (PVB) and spill-resistant pressure vacuum breaker (SPVB). The installation is subject to the following: (1) Shall be installed at least 12 inches above the usage point and a maximum of five feet above the floor or surrounding ground as measured to the highest test ports. (2) May be installed where subject to continuous supply pressure. (3) PVB shall not be installed inside a building. SPVB may be installed inside a building when used with risen hoses for bed pan washer and flushing rim sinks, wash-down hose reels in commercial kitchen, and for eye washes. (4) May be used for low or high health hazards against backsiphonage only. (e) Backflow preventers with intermediate atmospheric vents shall not be used for backflow protection. (f) Double check valve backflow preventer installation is subject to the following: (1) Shall be installed at least 12 inches to the bottom of the assembly and a maximum of five feet above the floor or surrounding ground as measured to the highest test ports. (2) May be used for low hazard application against both backpressure and backsiphonage. (3) This assembly shall not be installed in a pit. (g) Reduced pressure principle backflow preventers may be used on all direct connections subject to backpressure or backsiphonage. The installation is subject to the following: (1) Shall be installed at least 12 inches above the floor or surrounding ground to the opening of the relief valve and a maximum of five feet above the floor or surrounding ground as measured to the highest test ports. (2) May be used on both low and high hazard application in both backpressure and backsiphonage. (3) This assembly shall not be installed in a pit. (h) Dual check valves shall not be used for backflow protection.
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 49, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.