For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 25.10.020 — Scope of Code

Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 25.10.020

Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/23cfb40f-3485-4fa1-bda1-166373c8096c

25.10.020 - Scope of Code.

A. There is hereby established a Board of Examiners for Mechanical Contractors which shall govern mechanical and pipefitting contractors who perform work under this Code of the following prescribed nature: Contractors involved in any or all of the functions described herein, including the laying out, fabrication, assembly, installation and maintenance of pressurized piping and piping systems, fixtures and equipment for steam and hot water heating, cooling, lubricating, and industrial processing systems. B. The specific functions performed by said contractors would include any of the following: The selection of the type and size of pipe and related materials according to job specifications with respect to such work; the inspection of work sites to determine the presence of obstructions and to ascertain that holes will not cause structural weakness; the planning of the sequence of installation to avoid obstructions and activities of other construction workers, the cutting of pipe using a hacksaw, pipe cutters, hammer and chisel, cutting torch, pipe cutting machine or any other equipment used to perform the same general functions as this equipment; the threading of pipe using a threading machine; the bending of pipe by hand or with a pipe bending machine; the assembly and installation of a variety of metal and nonmetal pipe and pipe fittings including those made of brass, copper, glass and plastic with respect the work described above; the joining of by means of a threaded, caulked, soldered, brazed, fused or cemented joint; the securing of pipe to structures with clamps, brackets and hangers using hand tools; the installation and maintenance of refrigeration and air-conditioning systems including compressors, pumps, meters, and hydraulic controls and piping on commercial building; the testing of piping systems for leaks by increasing pressure in pipes and observing gauges attached to pipes for indication of leaks. C. All of the functions described in Subsection B of this section must be with respect to the specific work described at the outset of this section and such work shall not be interpreted in any event to include the installation, repair or maintenance of elevators. This Code shall apply to the above-described functions only as they relate to the new construction, replacement, maintenance, overhauling, general repair, renovation, rebuilding, rehabilitation or remodeling of mechanical systems which are: Steam piping on piping systems; pressurized piping systems in waste water and sewage treatment facilities; pressurized and vacuum piping in processing and industrial pipe installations through which hazardous, toxic or poisonous substances flow; pressurized piping in air conditioning systems in commercial structures of 14 tons and above; pressurized piping in heating systems in commercial structures of 300,000 British Thermal Units (BTUs) and above. D. This Code shall apply only to commercial structures and shall not apply to any residential building with six (6) or fewer dwellings. This Code shall not apply to any work of an aggregate mechanical contract price of twenty-five thousand dollars ($25,000.00) or less. This Code shall be interpreted in conjunction with other building and safety codes by the Building Commissioner or his designated representative. E. Alterations or repairs to any mechanical system shall conform to that required for a new mechanical system without requiring the existing mechanical system to comply with all of the requirements of this Code. Alterations or repairs shall not cause an existing mechanical system to become unsafe nor adversely affect the performance of the mechanical system. Where additions or alterations subject parts of existing systems to loads exceeding those permitted herein, such parts shall be made to comply with this Code. This Code does not apply to any mechanical work performed by employees of an owner, lessee, or keeper of the structure in which the work is performed or to any public utility and/or its employees.

(1994 C., § 25.10.020; Ord. No. 62579, § 2, 1992.)

Ask a question about St. Louis law

Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.