Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
40 C.F.R. § 408.152
in effectExcept as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any menhaden or anchovy fish meal reduction facility which utilizes a solubles plant to process stick water or bail water shall meet the following limitations.
Effluent characteristic
Effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of seafood)
BOD57.03.9
TSS3.71.5
Oil and grease1.40.76
pH(
1)(
1)
English units (pounds per 1,000 lb of seafood)
BOD57.03.9
TSS3.71.5
Oil and grease1.40.76
pH(
1)(
1)
1 Within the range 6.0 to 9.0.
(b) Any menhaden or anchovy fish meal reduction facility not covered under § 408.152(a) shall meet the following limitations:
Effluent characteristic
Effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of seafood)
BOD53.52.8
TSS2.61.7
Oil and grease3.21.4
pH(
1)(
1)
English units (lb/1,000 lb of seafood)
BOD53.52.8
TSS2.61.7
Oil and grease3.21.4
pH(
1)(
1)
1 Within the range 6.0 to 9.0.