§ 17.12.1010 — Amendment of Chapter 80 - NFPA 13D - 25 - Standard for the installation of sprinkler systems in one- and two-family dwellings and manufactured homes
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 17.12.1010
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/259a2a9c-7ed2-419a-ba55-b04742c20e83
17.12.1010 - Amendment of Chapter 80 - NFPA 13D - 25 - Standard for the installation of sprinkler systems in one- and two-family dwellings and manufactured homes.
The following sections of NFPA 13D - 25 edition, Standard for the Installation of Sprinkler Systems in One- and Two-family dwellings and Manufactured Homes, are amended to read as follows: 7.5.6.3(5) Sprinklers in closets containing clothes dryers shall be of the intermediate temperature classification or higher. 7.5.6.3(6) Where sprinklers may be subject to higher temperature such as closets containing heat producing equipment, unconditioned garages, exterior spaces, etc., intermediate temperature sprinklers shall be required. 7.5.10 Spare sprinklers shall be provided as required by NFPA 13-25 Section 16.2.7. 7.6 Alarms. Local waterflow alarms shall be provided on all sprinkler systems in homes. 8.3.4 Sprinklers shall be required in garages and carports. Sprinklers shall be required under open attached porches, exterior roofs, canopies, balconies, decks, or similar projections exceeding 4 feet in width and in. 8.3.5.1 is deleted. 8.3.5.1.1 is deleted. 8.3.5.1.2 is deleted. 8.3.5.1.3 is deleted. 8.3.5.1.4 is deleted. 8.3.5.1.5 is deleted. 8.3.6 is deleted. 8.3.8 is deleted. 8.3.11 Pilot Sprinklers. Pilot sprinklers shall be provided in attics spaces and between floors where floor/ceiling assemblies consist of open web wood joists or trusses. Pilot sprinklers shall be intermediate temperature rated, K=4.2, quick response. Pilot sprinklers shall be located within twelve inches of the structure and/or at the apex of each ridgeline where applicable. A sprinkler is required where the ridgeline and hips converge. Sprinklers shall be spaced at maximum thirty-foot centers (maximum fifteen feet from outside walls) and shall be located at all fuel-fired equipment, including furnaces, hot water heaters, etc. 10.4.9 is deleted. 11.2.1.1 All piping and attached appurtenances subjected to system working pressure shall be hydrostatically tested at 200 psi and shall maintain that pressure without loss for 2 hours.
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.