550.80. - Screening of mechanical equipment.
(a) In general. All mechanical equipment installed on or adjacent to structures shall be arranged so as to minimize visual impact on all sides of the equipment from adjacent streets, public paths, and adjacent properties as observed from ground level using one (1) of the following methods. All screening shall be at least sixty (60) percent opaque and shall be at least as tall as the equipment it is intended to screen. All screening shall be kept in good repair and in a proper state of maintenance. Exterior mechanical equipment, including ductwork but not exhaust vents, shall not be located on street-facing building facades.
(1) Screened by another structure. Mechanical equipment installed on or adjacent to a structure may be screened by a fence, wall or similar structure. Such screening structure shall comply with the following standards:
a. The required screening shall be permanently attached to the structure or the ground and shall conform to all applicable building code requirements.
b. The required screening shall be constructed with materials that are architecturally compatible with the structure.
c. Off-premises advertising signs and billboards shall not be considered required screening.
(2) Screened by vegetation. Mechanical equipment installed adjacent to the structure served may be screened by hedges, bushes or similar vegetation.
(3) Screened by the structure it serves. Mechanical equipment on or adjacent to a structure may be screened by a parapet or wall of sufficient height, built as an integral part of the structure.
(4) Designed as an integral part of the structure. If screening is impractical, mechanical equipment may be designed so that it is balanced and integrated with respect to the design of the building.
(b) Exceptions. The following mechanical equipment shall be exempt from the screening requirements of this section:
(1) Minor equipment not exceeding one (1) foot in height.
(2) Mechanical equipment accessory to a single-, two-, or three-family dwelling.
(3) Mechanical equipment located in the PR2 District not less than three hundred (300) feet from an urban neighborhood or residential mixed-use district.