For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14A-4-402.1 — General

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14A-4-402.1

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/2689705a-b737-4f23-8c81-854a33f5bba9

14A-4-402.1 General.

No permit is required for the following: Interior Work: 1. Painting, papering, tiling, carpeting, cabinets, counter tops, and similar finish work, without plumbing or electrical connections. 2. Drywall or plaster repair or replacement up to 1,000 square feet (93 m2) without alteration of plumbing or electrical devices or systems. 3. In-kind replacement of ceiling tiles that are not part of a fire-rated assembly. 4. In-kind replacement of interior doors that are not required to have a fire-resistance rating. 5. Temporary motion picture, television, and theatrical stage sets and scenery. 6. Nonfixed and movable fixtures, cases, racks, counters, and partitions not over 7 feet (2134 mm) in height. 7. Repairs described in Section 14A-4-402.2. Exterior Work: 1. Non-combustible sidewalks, patios, walkways, parking surfaces, and driveways that are not located in or on the public way, not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below. Exception: A permit is required to establish or expand any off-street parking or loading area. 2. Fences that are not more than 5 feet (1524 mm) above the ground on both sides and that conform to the Chicago Zoning Ordinance. 3. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, not supporting a surcharge, and not impounding liquids. 4. Swimming pools accessory to a Group R-5 occupancy that have a water depth of 48 inches (1219 mm) or less and a 90% water volume not greater than 5,000 gallons (18 925 L). 5. Shade cloth structures constructed for nursery or agricultural purposes, not including service systems. 6. Playground equipment accessory to a building of Group R occupancy. 7. Landscape plants and vegetation. 8. Hardscape elements, such as benches, bicycle racks, bollards, planters, and rocks, without plumbing or electrical connections, not exceeding 4 feet (1219 mm) in height. 9. Repairs described in Section 14A-4-402.2. Permanent Structures: 1. One-story detached structures, not more than 15 feet (4572 mm) above the ground, without plumbing, and used as tool and storage sheds, open gazebos, playhouses, and similar uses, or that are purely decorative, provided that the floor area is not greater than 150 square feet (14 m2 ). 2. Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons (18 925 L) and the ratio of height to diameter or width is not greater than 2:1. 3. Buildings and other structures that are subject to the permitting requirements in Chapter 10-40 of the Municipal Code. 4. Permanent vehicular or pedestrian bridges that are subject to the bridge permitting requirements of the Commissioner of Transportation. 5. Utility vaults and similar structures located entirely below the public way, if structurally independent from any structure adjoining the public way. 6. Permanent structures in the public way, other than buildings containing habitable space, subject to the jurisdiction of the Commissioner of Transportation. Temporary Structures: 1. Temporary structures, other than construction trailers, provided that the floor area is not greater than 400 square feet (37.2 m2) and no portion of the structure will be more than 15 feet (4572 mm) above adjacent grade. 2. Temporary stages and platforms not more than 24 inches (610 mm) in height. Electrical: 1. Minor electrical repair work, including the replacement of lamps or the connection of portable electrical equipment to permanently installed receptacles. 2. Electrical equipment used for radio and television transmissions regulated by the Federal Communications Commission. (A permit is required for power supply wiring and the installations of towers, antennas, and similar supporting structures). 3. The installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. 4. The installation or alteration of low voltage electrical fixtures, including telephones, computers, speakers, doorbells, and thermostats. (A permit is required for the installation of low voltage wiring.) 5. The installation or alteration of low-voltage and communication wiring in buildings of Group R occupancy with not more than 4 stories above grade plane and accessory structures, such as private garages and carports, located on the same lot as such buildings. Mechanical: 1. Portable heating appliances. 2. Portable ventilation appliances and equipment. 3. Portable cooling appliances. 4. Repair or replacement of any part within any heating, cooling, or ventilation appliance regulated by the Chicago Construction Codes that does not alter its function. 5. Self-contained refrigeration system containing 10 pounds (4.54 kg) or less of refrigerant and actuated by motors of 1 horsepower (0.75 kW) or less. 6. Portable fuel cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. Plumbing: 1. The stopping of leaks in drains or in water, soil, waste, or vent pipes within a building or within 5 feet (1524 mm) of the building foundation. (The removal and replacement of any drain pipe, water, soil, waste, or vent pipe, or concealed trap with new material requires a permit and inspections as provided in the Chicago Construction Codes. For requirements related to work affecting the building drain, see Chapter 11-16 of the Municipal Code.) 2. The clearing of stoppages or the repairing of leaks in pipes, valves, or fixtures and the removal and reinstallation of water closets, provided that such repairs do not involve or require the replacement or rearrangement of valves, pipes, or fixtures or work beyond 5 feet (1524 mm) from the building foundation. (For requirements related to work affecting the building drain, see Chapter 11-16 of the Municipal Code.) Conveyance Devices: 1. Repairs to a conveyance device involving replacement of existing parts with other parts that are identical to those that are replaced, provided a written log of such repairs must be maintained by the owner and made available to the building official upon request. Exception: A permit is required for any work that affects the exterior or designated interior elements of a Chicago Landmark. (Amend Coun. J. 10-7-20, p. 21791, Art. I, § 6; Amend Coun. J. 12-15-21, p. 42674, § 3; Amend Coun. J. 1-24-24, p. 8634, Art. III, § 1; Amend Coun. J. 6-17-26, p. 45214, Art. IV, § 12)

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.