9-14-26. - Measurement of Building Type Requirements.
The standards outlined in the tables in Sections 9-14-16 through 9-14-21, B.R.C. 1981, applicable to each building type, shall be measured and calculated consistent with the following standards: (a) Minimum Type A Frontage Streetwall Coverage. The minimum percentage of building facade along the Type A frontage of a lot is measured as follows: (1) Measurement. The minimum Type A frontage streetwall shall, at a minimum, equal the width of the principal structures, as measured within the minimum and maximum setback along the frontage, divided by the length of the frontage parallel to the property line following the street minus setbacks along perpendicular property lines. Refer to Figure 14-51. Minimum Type A Frontage Streetwall. (2) Courtyards. For some building types, courtyards located along the facade in the frontage setback count towards the minimum coverage. Refer to building type requirements of Sections 9-14-16 through 9-14-21, B.R.C. 1981. (3) Outdoor Space Type. Open spaces meeting the requirements of one of the outdoor space types established in this chapter are exempt from the minimum Type A frontage streetwall requirement.

Figure 14-51. Minimum Type A Frontage Streetwall (b) Frontage Setback. The minimum to maximum frontage setback shall be calculated and measured as follows. Refer to Figure 14-52. Frontage Setbacks. (1) Measurement. If the frontage is a Type A, B, or C frontage along a transportation improvement or waterway, the minimum and maximum frontage setbacks are measured from the outside edge of an easement for the transportation improvement or waterway, or, if no easement exists, from the parcel or lot line abutting the transportation improvement or waterway, as applicable. If the frontage is along a required outdoor space, the minimum and maximum frontage setbacks are measured from the outside edge of an easement for the outdoor space, or, if no easement exists, from the parcel or lot line abutting to the outdoor space, or if not within a separate parcel or lot, from the outer edge of the outdoor space as delineated on the site plan. (2) Height. All building facades located within the frontage setback shall meet the minimum building height of the building. (3) Encroachments. Awnings, architectural projections, balconies, and building mounted signage may extend beyond the frontage setback into any yard area but shall not extend into the street right-of-way or public easement unless approved with a revocable permit or lease, as applicable.

Figure 14-52. Frontage Setbacks (c) Limited Side Yard Parking. Where allowed by building type, parking may be located in the interior side yard, consistent with the following requirements: (1) The limited side yard parking lot is located fully in an interior side yard. (2) The limited side yard parking is configured as one double- or one single-loaded aisle of parking and the centerline of the aisle is located perpendicular to the street. (3) The limited side yard parking is not located on corners in any street yard. (4) No more than one limited side yard parking lot per building is located along any street frontage. (5) The limited side yard parking lots is not located next to another limited side yard parking lot. (d) Maximum Impervious and Additional Semi-Pervious Coverage. Impervious and additional semi-pervious coverage shall be calculated and measured as follows. Refer to Figure 14-53. Impervious and Semi-Pervious Coverage. (1) Maximum Impervious Coverage. The maximum impervious coverage is the maximum percentage of a lot permitted to be covered by structures, pavement, and other impervious surfaces. (2) Additional Semi-Pervious Coverage. In addition to the allowable impervious coverage on a site, a maximum amount of additional semi-pervious coverage is permitted.

Figure 14-53. Impervious and Semi-Pervious Coverage (e) Overall Minimum and Maximum Height. (Refer to Figure 14-54. Measuring Stories with Floor-to-Floor Height.) (1) Minimum Overall Height. Each building type requires a minimum number of stories. The building must meet the minimum required height along all Type A frontage facades and measured a minimum of thirty feet deep into the building. (2) Maximum Overall Height. Maximum heights are specified both in number of stories and overall dimension. This requirement applies to the entire building. (A) Towers. Where specifically allowed in the building type tables, Sections 9-14-16 through 9-14-21, B.R.C. 1981, towers may exceed the overall maximum height of the building type per subsection (f) of Section 9-14-25, "Cap Types," B.R.C. 1981. Towers shall not exceed the maximum height per section 84 of the charter of the City of Boulder. (B) Cap Type. Where specified in subsection (f) of Section 9-14-25, "Cap Types," B.R.C. 1981, certain cap types may allow additional height. (C) Maximum Heights per the City Charter. Under no circumstances may any building or structure exceed the height limitations established in section 84 of the charter of the City of Boulder. (D) Height Measurement Standards. Height shall be measured consistent with height measurement standards of Section 9-7-5, "Building Height," B.R.C. 1981, and the definition of "height" within Section 9-16-1, "General Definitions," B.R.C. 1981. (E) View Corridors. Height is subject to additional limitations where maximum heights are restricted pursuant to the regulating plan to preserve a view corridor. Refer to Sections 9-14-6, "Regulating Plans," and 9-14-7, "View Corridors," B.R.C. 1981. (3) Two Half Stories. If a building has both a half story within the roof and a half story that is partially above and partially below grade, the combined height of the two half stories shall be considered one full story. (f) Minimum and Maximum Height per Story. Each story is measured with a range of permitted floor-to-floor heights. Refer to Figure 14-54. Measuring Stories with Floor-to-Floor Height. (1) Measurement. Story height shall be measured in feet between the floor of a story to the floor of the story above it. Minimum and maximum floor-to-floor heights are required to be met along facades for a minimum of eighty percent of each story. (2) Single Story Buildings and Top Story Measurement. For single story buildings and the uppermost story of a multiple story building, the minimum floor-to-floor height shall be one foot less than that required per building type. The measurement shall be from the floor of the story to the ceiling. (3) Mezzanines. Mezzanines may be included within the floor-to-floor height of any story. Mezzanines occupying more than thirty percent of the floor area below and extending above the story's allowable floor-to-floor height shall count as an additional story and shall meet transparency requirements in subsection (e)(5), below. (4) Taller Spaces. Spaces exceeding the allowable floor-to-floor heights of the building type are permitted on any facade. On Type A and B frontage facades, the taller space is limited to no more than 35% of the length of the façade or 35 feet, whichever is less. Taller spaces may not exceed the total height of the surrounding stories, and the façade meet the transparency requirements of the surrounding stories.

Figure 14-54. Measuring Stories with Floor-to-Floor Height (g) Minimum Required Transparency. Per the requirements of each building type, a minimum amount of transparency is required on all stories of street, courtyard, and public way facades. The following applies to transparency requirements: (1) Measurement. Minimum facade transparency is measured from floor-to-floor of each story separately, except for required minimum ground story transparency (refer to Paragraph 9-14-26(g)(4), B.R.C. 1981, below). Refer to Figure 14-55. Measuring Minimum Facade Transparency. Transparency requirements shall be met with windows or glass in doors meeting the standards for transparency as defined in Section 9-14-8, "Definitions," B.R.C. 1981. The measurement may include the frame, mullions, and muntins, but shall not include trim or casing.

Figure 14-55. Measuring Minimum Facade Transparency (2) Blank Wall Limitations. Refer to Figure 14-56. Measuring Blank Wall Limitations. (A) Intent. The intent of the blank wall limitations is to avoid long stretches of blank walls, distribute transparency within a story, and ensure that windows are located at the height of a person standing within the story. (B) Where the building type standards impose blank wall limitations, the following applies: (i) No rectangular area greater than thirty percent of the story's facade, as measured floor to floor, shall be without transparency. Refer to Figure 14-56. Measuring Blank Wall Limitations. (ii) No horizontal segment of a story's facade greater than fifteen feet in width shall be without transparency. Refer to Figure 14-56. Measuring Blank Wall Limitations.

Figure 14-56. Measuring Blank Wall Limitations (3) Exception. When the facade of any story is located less than six feet from another parallel building facade, no minimum transparency is required for that story. (4) Minimum Ground Story Transparency. When required by the building type tables of Sections 9-14-16 through 9-14-21, B.R.C. 1981, ground story transparency shall be measured between two feet and either eight or ten feet, as specified per building type, from the average grade at the base of the facade. The minimum ground story transparency requirements supersede the minimum transparency required for the building type. (5) Mezzanines. Mezzanines shall be treated as a separate story and include the required upper story transparency amounts. (6) Tall Stories. Stories that are eighteen feet or taller in height shall include additional transparency consistent with the following standards. Refer to Figure 14-57. Transparency on Tall Stories. (A) Separate Ground Story Transparency Required. When a separate minimum ground story transparency is required per the building types requirements of Sections 9-14-16 through 9-14-21, B.R.C. 1981, the facade design shall fulfill that requirement in addition to a minimum of twenty-five percent transparency for the remainder of the ground story. (B) No Separate Ground Story Transparency Required. Except on a ground story facade to which a Type A frontage ground story facade transparency requirement applies, a tall story shall be treated as two separate stories, divided in half horizontally, with the minimum transparency per story applied to each half. (7) Half Stories. All half stories located within the roof structure and within visible basements are required to meet the minimum required transparency.

Figure 14-57. Transparency on Tall Stories (h) Minimum Number of Required Entrances. Entrances shall be provided consistent with the entrance location and number requirements established for the building type and consistent with Figure 14-58. Number of Required Entrances.

Figure 14-58. Number of Required Entrances Ordinance No. 8697 (2025)