Multi-family supplemental design criteria for RC Districts.
Coral Springs Land Development Code § 250125
in effectSec. 250125. - Multi-family supplemental design criteria for RC Districts.
Where one (1) or more building(s) for dwelling purposes are erected and placed on a plot in any RC District, minimum front, side and rear yards shall be provided as required by this chapter. The following regulations apply to each multifamily project, superseding any zoning district regulations to the contrary.
(1) A minimum fifteen-foot wide landscape strip shall be required between any internal vehicular use area and an abutting right-of-way, with the exception of master parking areas. However, if the abutting right-of-way is an arterial identified on the Broward County Trafficways Plan, the required landscape strip shall be twenty-five (25) feet in width.
(2) Sidewalks required.
(a) All buildings, parking areas and amenities shall be connected by sidewalks or interior walkways, and sidewalks along interior circulation drives shall connect with off-site sidewalks.
(b) When parking is provided in front, behind or on the side, of a building along an interior circulation drive, a concrete sidewalk with raised curb shall be constructed between the parking spaces and the building, with connecting sidewalks to the building entrance. If such sidewalk is provided on only one side of an interior circulation drive, it shall be at least five (5) feet in width. If sidewalks are provided on both sides of the interior circulation drive, they shall be a minimum of four (4) feet wide.
(c) When garages are provided resulting in vehicles backing out onto interior circulation drives, a concrete sidewalk shall be constructed between the driveway reservoir and the drive lane.
(3) Maximum allowable building length.
(a) RC-6 District | 120 feet
(b) RC-12 District | 160 feet with the average of all residential buildings not to exceed 130 feet
(c) RC-15 District | 160 feet with the average of all residential buildings not to exceed 130 feet
(4) Building separations.
BUILDING SEPARATIONS
Side to side | Side to front or back | Front to front, front to back, or back to back
RC-6 | Minimum 20 feet or the average of the height of adjacent buildings*. An additional 1 foot of separation shall be required for each 3 feet the average length of adjacent buildings exceeds 100 feet. | 25 feet | Minimum 35 feet or the average of the height of adjacent buildings whichever is greater. A minimum average separation of 40 feet shall be required for all buildings.
RC-12 and RC-15 | Minimum 20 feet or the average of the height of adjacent buildings*. An additional 1 foot separation shall be required for each 3 feet the average length of adjacent buildings exceeds 130 feet. | 25 feet | Minimum 35 feet or the average of the height of adjacent buildings whichever is greater. A minimum average separation of 40 feet shall be required for all buildings.
*If the height of the end of the building is lower than the height of the adjacent roof section on the same building by at least five (5) feet over a width of at least twenty (20) feet, the lower height may be used in calculating the average height of building for this section.
(5) Special separations for buildings in linear form. Whenever buildings are arranged in a linear form with a combined length in excess of three hundred (300) feet, they shall have a minimum separation twice the distance specified above; except that buildings staggered at least fifteen (15) feet or angled greater than fifteen (15) degrees shall not be considered in linear form.
(6) Variations in building height.
(a) For buildings of two (2) or three (3) stories in height and not exceeding one hundred (100) feet in length, at least fifteen (15) per cent of the roof line shall have a variation in height, or an average variation in height, of at least five (5) feet.
(b) For buildings of two (2) or three (3) stories in height and in excess of one hundred (100) feet in length, at least two (2) portions of the building shall have a variation in height, or an average variation in height, of at least five (5) feet. The combination of said required variations in height shall amount to not less than fifteen (15) per cent of the length of the building.
(c) For buildings of four (4) or more stories in height at least fifteen (15) per cent of the roof line shall have a variation in height, or an average variation in height, of at least ten (10) feet.
(7) Variations in building facade.
(a) For buildings not exceeding one hundred (100) feet in length, at least fifteen (15) per cent of the building face shall have a variation in setback of at least five (5) feet.
(b) For buildings in excess of one hundred (100) feet in length, at least two (2) portions of the building shall have a variation in setback of at least five (5) feet. Variations of less than five (5) feet shall not count toward this requirement. The combination of said required variations in setback shall amount to not less than fifteen (15) per cent of the length of the building.
(8) Minimum unit widths. The minimum permissible width for an individual dwelling unit, center of common wall to center of common or exterior wall, shall be twenty (20) feet for the majority of the unit.
(9) Provision of emergency access. Each multifamily building shall have at least one (1) face accessible within fifty (50) feet of paved or stabilized access for emergency vehicles, and all faces of each building shall be within two hundred (200) feet of paved or stabilized access.
(10) Traffic enforcement agreement required. The owner and/or management of each multifamily project shall enter into a Traffic Enforcement Agreement permitting the city to enforce traffic laws including moving violations, parking requirements, towing of illegally parked vehicles, maintaining emergency vehicle access to each unit, and marking or signing areas adjacent to fire hydrants or other fire connections to prohibit blocking access thereto when deemed necessary by city officials at their sole discretion. Signage shall comply with the "Manual on Uniform Traffic Control Devices" and shall be installed at the owners expense.
(11) Minimum useable open space.
(a) Multifamily development shall contain minimum usable open space in accordance with the following schedule:
RC-6 District: | Two and one-half (2.5) per cent of the plot area.
RC-12 District: | Five (5) per cent of the plot area.
RC-15 District: | Six (6) per cent of the plot area.
(b) Multifamily developments of five (5) acres or more in size shall provide an improved recreation area. Said improved recreation area shall have at least fifteen (15) square feet of area for each dwelling unit with two (2) or more bedrooms. The minimum size for any improved recreation area shall be seven hundred fifty (750) square feet. The improved recreation area shall either be located away from streets, lakes or canals or shall be fenced. The multifamily development shall locate the improved recreation area in an area which is not directly adjoining or across a water body from any RS, RC-6 or RD-8 zoned plot unless it is impractical, as determined by the director of development services, or the multifamily development employs other site planning criteria such as increased and staggered plantings to reduce noise. The improved recreation area and equipment shall be constructed in accordance with the United States Consumer Products Safety Commission guidelines. A plot may use all or a portion of its usable open space requirement to satisfy the requirement to provide an improved recreation area. However, the requirement for an improved recreation area will not be applied to multifamily developments, or those portions of a multifamily development, restricted by deed, a notation on the face of the plat or other recorded instrument which in the opinion of the city attorney creates said restriction to age-restricted communities.
(12) Balconies. Balconies designed for other than purely ornamental purposes shall be a minimum of six (6) feet in depth.
(Code 1972, § 20-24; Ord. No. 97-135, § 2, 9-16-97; Ord. No. 2023-101, § 117, 4-19-23)