SEC. 10-50903.6. - WHERE REQUIRED IN EXISTING BUILDINGS AND STRUCTURES.
903.6 Where required in existing buildings and structures. An approved automatic sprinkler system or other approved automatic fire extinguishing system shall be provided in existing buildings and structures, including R-3 occupancies and one- and two-family dwellings, in those circumstances described in this Section and where required in Chapter 11. Installation requirements shall be as set forth for new buildings by Sections 903.2 through 903.2.21, and where applicable, the California Residential Code. 1. Building additions. When a building addition to any existing building is 1,750 square feet or more and the total proposed building area is 5,000 square feet or larger, an approved automatic sprinkler system shall be installed throughout the building. The 1,750 square foot threshold for automatic fire sprinkler installation shall be cumulative over the life of the building. Exception: Building additions of entirely non-combustible construction and non-combustible uses such as covered pedestrian walkways. 2. One- and two-family dwelling relocations. When any existing Group R-3 building, or any one or two family dwelling is relocated, an approved automatic sprinkler system shall be installed throughout the building in accordance with 903.3.1.3 (NFPA 13D). This requirement shall supersede any exceptions found in the California Building Standards Code, including California Residential Code. 3. Change of occupancy or use. In any existing building 5,000 square feet or larger, when a change of occupancy or use in accordance with the California Building Code or the California Existing Building Code is made and the proposed new occupancy or use is more hazardous to life and safety than the existing occupancy or use, an approved automatic fire extinguishing system shall be installed throughout the building. The determination of a more hazardous use or occupancy shall be made in accordance with the California Existing Building Code and Fire Department Policy, whichever is the most restrictive. Exceptions: (a) If the area in which the change of occupancy or use occurs is less than 1,750 square feet of the actual floor area of the existing building and the area of the new occupancy is 2,499 square feet or less, and an automatic sprinkler or fire extinguishing system is not required based on occupancy by Section 903, an automatic sprinkler or automatic fire extinguishing system is not required for any portion of the building. The 1,750 square foot limit is cumulative over the life of the building. (b) If the area in which the change of occupancy or use occurs exceeds 1,750 square feet but is less than 50% of the gross floor area of the existing building, only that portion of the building changing occupancy is required to have an approved automatic sprinkler or automatic fire extinguishing system installed. An approved fire separation shall be required between portions of the building equipped with an automatic fire sprinkler or automatic fire extinguishing system and those portions without. (c) If an individual or cumulative changes of occupancy or use exceed 50% of the gross floor area of the existing building, then the entire building shall have an approved automatic sprinkler or automatic fire extinguishing system installed throughout the building. 4. Fire Damage Repairs. An approved automatic sprinkler system shall be installed as a condition of a fire damage repair building permit as follows: (a) When a fire occurs in any existing building or occupancy, including R-3 occupancies and one- and two-family dwelling units, and the building permit repair costs exceed 25% of the current building valuation, an automatic sprinkler system shall be installed throughout the building as required for a new building in Section 903 or R309, regardless of the building square footage. (b) When a fire occurs in any R occupancy, including one- and two-family dwelling units, and building permit fire repair costs in the kitchen area of the dwelling unit(s) exceeds $999, a single fire sprinkler head or other approved automatic extinguishing system shall be installed in the kitchen per Fire Department Policy, regardless of the building square footage. (c) Fire damage repair costs and building valuation shall be determined using the latest ICC Building Valuation Tables in use by the Planning and Development Department at the time of the issuance of the fire damage repair permit. 5. R-2 condominium conversions. Existing group R-1 or R-2 buildings proposed for conversion to condominiums shall have an approved automatic sprinkler system installed throughout the entire building as a condition of approval, regardless of the building square footage. 6. R-1 to R-2 conversions. Existing group R-1 buildings proposed for conversion to R-2 shall have an approved automatic sprinkler system installed throughout the entire building as a condition of approval, regardless of the building square footage. 7. A-1 and A-2 occupancies. In existing group A-1 and group A-2 occupancies an approved automatic sprinkler system shall be installed throughout the entire building as a condition of any building permit where the permit cost is nine hundred ninety-nine dollars ($999) or more, regardless of the building square footage. Exception: Building permits issued exclusively for mechanical systems, plumbing systems, electrical systems and re-roofing only.
(Added Ord. 2025-039, § 3, eff. 10-31-25).
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.