For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.50.090 — Repair of underground storage tanks

Victorville, California, Municipal Code (Supp. No. 57: codified through Ordinance No. 2466, passed April 7, 2026) · Victorville Municipal Code § 6.50.090

Corpus is an independent public-information project, not the official City of Victorville website. Stable reference: corpuslaw.us/code/28b55ffd-88f2-4134-afac-943035cf7483

6.50.090 - Repair of underground storage tanks.

If there has been any unauthorized release, as defined in subsection (d) of Section 6.50.075, from an underground storage tank containing motor vehicle fuel not under pressure, the permit holder may repair the tank once by an interiorcoating process if the tank meets all of the following requirements: (1) An ultrasonic test, or comparable test, has been conducted to determine the thickness of the storage tank. If the result of the test indicates that a serious problem exists with regard to the tank, as determined by the person conducting the test, the health officer may require additional corrosion protection for the tank or may deny the authorization to repair. (2) A hydrostatic test is an alternative to the ultrasonic test in subsection (1). If the result of the test indicates that a serious problem exists with regard to the integrity of the tank, as determined by the person conducting the test or the health officer, the health officer may require additional protection for the tank or may deny authorization for the repair. (3) A vacuum test has been conducted with a result indexed at not more than five and three-tenths inches of mercury. This requirement shall not be applicable if technology is not available for testing the tank on site using accepted engineering practices. (4) Following the repair, the standard installation testing for requirements for underground storage tanks specified in Section 2-7.3 of the Flammable and Combustible Liquids Code, adopted by the National Fire Protection Association on November 20, 1983 (NFPA 30-1981), and published in the 1982 Edition of the National Fire Code shall be followed. (5) The material used to repair the tank by an interior-coating process is compatible with the motor vehicle fuel that is stored, as approved by the Board by regulation. (6) The material used to repair the tank by an interior-coating process is applied in accordance with nationally recognized engineering practices such as the American Petroleum Institute's recommended practice No. 1631 for the interior lining of existing underground storage tanks. (7) The Board may develop regulations, in consultation with the State Fire Marshal, for the repair of underground storage tanks, and the standards in this section shall remain in effect until the adoption of these regulations.

(Ord. 918 § 1 (part), 1983)

Ask a question about Victorville law

Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.