Sec. 13-809. - Grease control equipment sizing.

1. Minimum acceptable size of grease control equipment for each FSE classification will be as follows: Class 1: Deli, ice cream shops, beverage bars, mobile food vendors—20gpm/40 pound grease trap (NAICS 72213, 722330). Class 2: Limited-service restaurants/caterers/Daycares—1,000-gallon grease interceptor (NAICS 722211, 722320). Class 3: Full service restaurants—1,000-gallon grease interceptor (NAICS 722110). Class 4: Buffet and cafeteria facilities—1,500-gallon grease interceptor (NAICS 72212). Class 5: Institutions (schools, hospitals, prisons, etc.)—2,000-gallon grease interceptor (NAICS 722310). 2. To calculate the appropriate size GCE, the FSE's engineer, architect or contractor should use a formula that considers fixture units, storage capacity, type of facility and an adequate retention time. The grease control equipment minimum acceptable size for the above listed FSE classifications (class 1 through 5) must be met. 3. The city will review GCE sizing information received from the completed grease control inquiry form or the FSE's engineer, architect or contractor. The city will make a decision to approve, or require additional grease interceptor volume, based on the type of FSE, the number of fixture units, and additional calculations. Grease interceptor capacity should not exceed three thousand (3,000) gallons for each interceptor tank. In the event that the grease interceptor calculated capacity needs to exceed three thousand (3,000) gallons, the FSE shall install an additional interceptor of the appropriate size. If additional interceptors are required, they shall be installed in series. 4. Grease interceptors that are installed in series shall be installed in such a manner to ensure positive flow between the tanks at all times. Therefore, tanks shall be installed so that the inlet invert of each successive tank shall be a minimum of two (2) inches below the outlet invert of the preceding tank. 5. Grease control equipment must remove fats, oils, and grease at or below the city limit of one hundred (100) mg/L.

(Ord. No. 26-2008-09, 12-4-08)

Ask a question about Clarksville law

Corpus searches the Clarksville sections it holds and shows the ones that match, with their citations. Free, no sign-in.