Sec. 740-303. - Building measurements and calculations.
A. Building area. When looking perpendicularly from above, the total horizontal area of ground, within the lot or project, covered by the primary structures plus area covered by all accessory buildings, all minor residential structures and all residential support facilities or amenities.
[image omitted; see the official code]
Diagram K Example of what is included in Building Area
Permanent overhangs, balconies, eaves and similar extensions are included in building area. The ground area of the extension not provided with surrounding exterior walls is the area immediately under the extension, projection of the roof, or the floor above (see Diagram K). Temporary extensions, such as fabric awnings, are not included.
Building area does not include improvements at grade level or within 18 inches of grade level, such as patios, inground pools, gardens, or walkways. The following types of improvements are not included in Building Area:
1. Amateur Radio Antenna;
2. Fences or similar structural barrier;
3. Reserved;
4. Geothermal, Solar or Wind Renewable Energy Facility;
5. Minor Residential Features;
6. Personal Garden;
7. Satellite Dish Antenna;
8. Underground Storeroom or Safe Room;
9. Walkways and driveways.
B. Building height. For buildings in which the highest roof is a flat roof, the vertical distance from the grade level abutting the façade measured to the highest point of the coping of the flat roof.
For buildings in which the highest roof is a mansard roof, the vertical distance from the grade level abutting the façade measured to the deck line of a mansard roof.
For buildings in which the highest roof is a pitched or gabled roof, the vertical distance from the grade level abutting the façade measured to the height of the highest gable of a pitched or hipped roof (see Diagram L).
[image omitted; see the official code]
Diagram L Building Height
C. Floor area calculations.
1. Calculating floor area. Floor area is the sum of all horizontal surface areas of all floors of all roofed portions of a building measured from the exterior faces of the exterior walls or roofs, or the centerlines of party walls separating abutting buildings or portions thereof.
However, this does not include the following:
a. Areas with a vertical height clearance less than 78 inches;
b. Exterior open balconies, and open porches;
c. Floor or basement floor area devoted to off-street parking or loading facilities, including aisles, ramps, and maneuvering space.
2. Calculating floor area ratio. Floor area ratio is the ratio of total square footage of all floors in all buildings within the project to the square footage of the project. The sum of the floor area for each floor in all buildings within the project is divided by the lot area of the project to yield the floor area ratio.
3. Calculating net floor area. Net floor area is the sum of the gross horizontal areas of the floors and basements of the building devoted to permitted uses, except floor areas devoted primarily to storage purposes; floor area devoted to off-street parking or loading facilities, such as aisles, ramps, and maneuvering space; floor area used for utilities, elevator shafts, main corridors and stair wells, or floor area for toilets, lounges, or cafeterias for the use of employees only. Provided, however, for the purposes of determining off-street loading requirements, net floor area shall include floor area devoted primarily to storage purposes, but shall otherwise be defined as above.
D. Open space calculations.
1. Calculating uncovered open space. In the D-A, D-S, D-1, D-2, D-3, D-4, D-5, D-5II Districts and in the D-8 District on lots improved with a single-family detached dwelling, or two-family dwelling, uncovered open space is the lot area minus the building area. Any Game Court area counts as Building Area.
In other instances, Uncovered Open Space is the Lot Area, minus the Building Area plus the Usable Roof Area.
2. Calculating covered open space. Covered open space is the horizontal area of all exterior space within the lot or project that is open and exposed to the weather, but not open above to the sky, and is not used for vehicles. It includes total horizontal area of all exterior balconies over 25 square feet in size, porches, and exterior spaces covered by portions of buildings.
3. Calculating open space. In the D-A, D-S, D-1, D-2, D-3, D-4, D-5, D-5II Districts and in the D-8 District on lots improved with a single-family detached dwelling, or two-family dwelling, open space is uncovered open space.
In other instances, open space is the total of uncovered open space plus covered open space.
4. Calculating open space ratio. In the D-A, D-S, D-1, D-2, D-3, D-4, D-5, D-5II Districts and in the D-8 District on lots improved with a single-family detached dwelling, or two-family dwelling, the open space is divided by the lot area and then multiplied by 100 to yield the percentage of open space.
In other instances, open space ratio is the ratio of the area of all open space to all of the floor area. The open space is divided by the floor area to yield the open space ratio for the project.
E. Livability space calculations. Livability space is the lot area minus total building area minus all vehicle areas plus covered open space plus usable roof area.
Livability space ratio is the livability space divided by the total floor area within the project.
F. Transparency calculations.
1. Calculating ground floor transparency. Each side of the building is measured separately. Any reference to building width does not include eaves, awnings or similar projections.
Determination of ground floor wall area:
On any facade or side of a primary building that is located 50 feet or more of a local, collector or arterial street and has a public pedestrian entrance, the height between three feet and eight feet above grade level (i.e. five feet) is multiplied by the portion of the width of that side of the building that is located within 50 feet of each side of each entrance.
On any facade or side of a primary building that is located within 50 feet of a local, collector or arterial street, the height between three feet and eight feet above grade level (i.e. five feet) is multiplied by the total width of that side of the building.
Within this ground floor wall area, the transparent areas are those in which a person with normal acuity is able to see in and out of the building. These transparent areas may be covered with glass, plastic or completely open and may be incorporated into the wall or part of a door.
The sum of the transparent areas of the ground floor wall area is divided by the ground floor wall area and then multiplied by 100 to yield the percentage of transparency.
[image omitted; see the official code]
[image omitted; see the official code]
Diagram M Ground floor transparency
2. Calculating transparency of upper floors. Each upper floor is measured separately. Each side of the building is measured separately.
The distance between the floor level and the ceiling of the floor is multiplied by the width of that side of the building at that floor level; this is the wall area. Building width does not include eaves, awnings, balconies or similar projections. Within this wall area, the areas in which a person with normal acuity is able to see in and out of the building are totaled; these transparent areas may be covered with glass, plastic or completely open. The sum of the transparent areas of the wall area is divided by the wall area and then multiplied by 100 to yield the percentage of transparency.
[image omitted; see the official code]
Each floor must meet the minimum transparency standard except for the top floor of any building five or more floors in height.
[image omitted; see the official code]
Diagram N Upper floor transparency — Facade
[image omitted; see the official code]
Diagram O Upper floor transparency — Side of building
(G.O. 64, 2015, § 2; G.O. 37, 2018, § 2; G.O. 23, 2023, § 2)