§ 21.56.100 — Development and design standards for all Wireless Telecommunications Facilities and co-location facilities
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 21.56.100
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/29ba723d-dcf0-4f1c-a149-8307fa8edc51
21.56.100 - Development and design standards for all Wireless Telecommunications Facilities and co-location facilities.
The following standards shall apply to all Wireless Telecommunications Facilities and co-location facilities: A. The adverse visual impact of Wireless Telecommunications Facilities shall be avoided, minimized, and mitigated by: 1. Siting new Wireless Telecommunications Facilities outside of public viewshed whenever feasible; 2. Maximizing the use of existing vegetation and natural features to cloak Wireless Telecommunications Facilities; 3. Constructing towers or monopoles no taller than necessary to provide adequate coverage, network capacity, and service quality; 4. Grouping buildings, shelters, cabinets, ground lease areas, and other equipment together, to avoid spread of these structures across a parcel or lot; 5. Screening Wireless Telecommunications Facilities and co-location facilities with landscaping consisting of drought-tolerant plant material. All ground lease areas shall be landscaped with climbing vines on the exterior of the enclosure wall, planted not more than four feet (4') on center. Adequate irrigation systems shall be provided for landscaping. The landscape screening requirement may be modified or waived by the Director of Development Services in instances where landscaping would not be appropriate; and 6. Painting all equipment to blend with the surrounding environment as specified in Subsection 21.56.100.C (Paint Colors). B. Pole design. Use of monopoles that attempt to replicate trees or other natural objects are strongly discouraged and shall be used only as a last resort when all other options have been exhausted, since: 1. Artificial trees cannot presently be made to resemble natural trees in a sufficiently believable and realistic fashion; and 2. Such attempts to replicate nature are disingenuous by their obvious falsity and therefore increase, rather than reduce, visual blight. C. Paint colors. Paint colors for a Wireless Telecommunications Facility and co-location facility shall minimize the facility's visual impact by blending with the surrounding environment, terrain, landscape, or buildings (not sky colors, as the sky is a luminous source of light at all times and no non-luminous object can physically be made to blend with the sky). Paint colors shall be subject to the review and approval of the Department of Development Services. Color verification shall occur in the field after the applicant has painted the equipment in the approved color(s), but before the applicant schedules a final inspection. D. Roof/building-mounted facilities. For roof/building-mounted Wireless Telecommunications Facilities and co-location facilities, the following standards also shall apply: 1. Antenna location. a. Antennas mounted on the facade of a building are strongly discouraged, but if approved, must be fully integrated into the architecture of the existing structure or otherwise screened from public view. "Stealth boxes" enclosing facade antennas shall not be considered adequate screening; b. Antennas shall be mounted on building rooftops, roof decks, or penthouses whenever feasible as a preferred alternative to facade-mounting. Antennas located on the building rooftop shall be located above the ceiling plate of the highest occupied floor; c. Antennas shall be located as far away as possible from the edge of the building or roof, with the goal of reducing or eliminating visibility of the installation from any and all vantage points. 2. Equipment location. a. All equipment appurtenant to a roof/building-mounted wireless telecommunications site shall be located inside an existing building whenever possible, to the satisfaction of the Director of Development Services; b. If it is physically impossible for equipment to be located inside an existing building and the equipment is to be located on a building rooftop, the equipment shall be subject to the same screening and location requirements as the antennas. If no space for the equipment is available for lease in a building because all possible spaces are leased and occupied, this shall constitute a physical impossibility. 3. Screening required. a. Where physically possible, antennas and equipment shall be located entirely within an existing architectural feature or screening device. This shall include areas used or occupied by other wireless service providers where feasible. b. All antennas and equipment mounted on a building rooftop shall be screened in a manner that is architecturally compatible with the existing building and is otherwise made as unobtrusive as possible. Screening shall use matching colors, materials, and architectural styles to create a harmonious addition to the building's architecture without disrupting its form, volume, massing, or balance. c. All antennas, including panel antennas, microwave antennas, GPS antennas, any other antennas, and all other equipment mounted on the building, shall be concealed behind the screening device on all sides such that the antennas and appurtenant equipment is not visible from the exterior of the subject property, from other property, or the public right-of-way. d. All cable trays and cable runs shall be located within existing building walls whenever physically possible. Cable trays and runs on the facade of a building are strongly discouraged. Any facade-mounted cable trays and runs shall be painted and textured to match the building and shall be mounted as close to the facade surface as possible, with no discernible gap between. Cable trays and runs mounted on a roof deck and below the height of the parapet wall or screening device shall be exempt from this requirement, provided they are fully screened by the parapet wall or screening device. Exposed cable trays and runs on a sloped roof are prohibited. e. At the discretion of the Staff Site Plan Review Committee, part or all of a proposed roof/building-mounted Wireless Telecommunications Facility or co-location facility may be exempted from screening requirements if the best feasible screening design would result in greater negative visual impacts than if part or all of the proposed installation were unscreened. 4. Restriction on Historic Landmark structures. Installation of a roof/building-mounted Wireless Telecommunications Facility or co-location facility at a City-designated Historic Landmark shall make no changes to the external appearance of the building unless approved by the Cultural Heritage Commission. E. Non-reflective materials. The exteriors of Wireless Telecommunications Facilities and co-location facilities shall be constructed of non-reflective materials. F. Underlying setbacks. Wireless Telecommunications Facilities and co-location facilities shall comply with all the setback requirements of the underlying zoning district(s), except as modified by this Chapter. G. Height. Facilities subject to the provisions of this Chapter may be built and used to a greater height than the limit established for the zoning district in which the structure is located, except as otherwise provided below: 1. No monopole or other freestanding structure shall ever exceed a maximum height of one hundred twenty feet (120') in any zoning district. In any Residential (R) or Institutional (I) zoning district, or Residential/Institutional Planned Development (PD) district, no monopole or other freestanding structure shall exceed a maximum height of fifty-five feet (55'). However, if an applicant demonstrates that the monopole or structure will accommodate a minimum of two (2) carriers, the site may be permitted at a maximum height of sixty feet (60'); or the applicant demonstrates that the monopole or structure will accommodate three (3) carriers, the site may be permitted at a maximum height of sixty-five feet (65'); 2. A roof/building-mounted Wireless Telecommunications Facility shall not exceed the maximum height allowed in the applicable zoning district, or ten feet (10') above the building roof deck, whichever is higher, except that in any R-1, R-2, or R-3 district, no roof/building-mounted site shall exceed the maximum height for structures allowed in that district; 3. Notwithstanding the height limits set forth in the preceding Sections, for facilities to be mounted on towers used for high-voltage electrical power transmission between generating plants and electrical substations (not utility poles), the antennas may be mounted as high as necessary on the tower, provided that the top of the highest antenna is not higher than the top of the existing tower. H. Accessory buildings. In any zoning district, accessory buildings in support of the operation of the Wireless Telecommunications Facility or co-location facility may be constructed, provided that they comply with the development standards set forth for accessory structures for the zoning district in which the site is located. I. Footprint. The overall footprint of each Wireless Telecommunications Facility shall be as small as possible, to the satisfaction of the Staff Site Plan Review Committee. J. Generators and emergency power. Diesel generators are allowed as an emergency power source, although they are discouraged. When a feasible alternative technology for permanent on-site backup power becomes available (for example, fuel cells) the Department of Development Services may require the use of such technology in lieu of a diesel generator, unless the applicant provides written documentation explaining why such an alternative is not feasible. All generator installations shall comply with all containment requirements of the applicable Fire and Building Codes, without exception. Unless otherwise approved by the Director of Public Works or if within the Coastal Commission's retained permit jurisdiction area, by the Coastal Commission or its Executive Director, generators and emergency power source for wireless facilities located in the public right-of-way are prohibited. K. Ground lease area enclosures and landscaping. If equipment appurtenant to a facility is to be located in a ground lease area, the lease area shall be enclosed by a CMU block wall, or other appropriate fence, to the satisfaction of the Staff Site Plan Review Committee. The fence shall be of a minimum height of six feet six inches (6'6") in residential districts, and eight feet (8') in other districts, unless waived at the discretion of the Director of Development Services in cases of infeasibility. The exterior of all ground lease areas shall be landscaped with drought-tolerant plant material, and adequate irrigation systems shall be provided for landscaping. Climbing vines shall be provided on the exterior of the enclosure wall, planted not more than four feet (4') on center. This landscaping requirement may be modified or waived by the Director of Development Services in instances where landscaping would not be appropriate.
(ORD-20-0025 § 13, 2020; ORD-18-0012 § 1, 2018)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.