§ 18.72.030 — Definitions
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.72.030
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/2a621feb-ee4b-432a-b0b2-54777a98edb6
18.72.030 - Definitions.
For the purposes of this chapter, the applicable definitions in Chapter 2, Section 1602 of the California Building Code adopted in Chapter 18.40; Sections 1.2, 3.1.1, 4.1, 5.2, 6.2 and 11.2 of ASCE 7-16, and the following shall apply: "Anchorage system" means the system of all structural elements and connections which support the concrete or masonry wall in the lateral direction, including diaphragms and subdiaphragms, wall anchorage and continuity or crosstie connectors in subdiaphragms and main diaphragms. "Commenced construction" means construction pursuant to a valid building permit that has progressed to the point that one of the called inspections as required by the Department has been made and the work for which the inspection has been called has been judged by the Department to be substantial and has been approved by the Department. "Existing building" means an erected building for which a legal building permit and a Certificate of Occupancy have been issued. "Flexible diaphragm" means any diaphragm constructed of wood structural panel, diagonal or straight wood sheathing, metal decking without a structural concrete topping, or horizontal rod bracing. "Historical building" means any building designated or currently in the process of being designated as a historical building by an appropriate federal, State or City jurisdiction. "Reinforced concrete wall" means a concrete wall which has fifty percent (50%) or more of the reinforcing steel required for reinforced concrete in Chapter 19 of the California Building Code adopted in Chapter 18.40. "Reinforced masonry wall" means a masonry wall which has fifty percent (50%) or more of the reinforcing steel required by Section 2106.1 of the California Building Code adopted in Chapter 18.40. "Retrofit" strengthens or structurally improves the lateral force-resisting system of an existing building by alteration of existing or addition of new structural elements. "Tilt-up concrete wall" is a form of precast concrete panel construction either cast in the horizontal position at the site and after curing, lifted and moved into place in a vertical position, or cast off-site in a fabricator's shop.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.
