Sec. 5-66. - Types of construction.

(a) General. All buildings and structures, hereafter erected within the boundaries of the fire limits shall be of a Type 1, 2A, 2B, 4 or 3A construction as defined in SBC-1, Article 4 and regulated in SBC-1, Table 401; and shall be constructed within the height and area limitations of SBC-1, Table 501, except as herein provided. Open parking structures may be constructed as permitted under SBC-1, Section 617.0. (b) Type 2C, 3B or 5A construction permitted. Buildings and structures and additions to existing buildings and structures, hereafter erected within the fire limits may be of Type 2C, 3B or 5A construction as defined in Article 4 and regulated in SBC-1, Tables 401 and 501, when constructed and located in accordance with the requirements of Table 4.2. Table 4.2 Exterior Wall Fire-Resistance Rating Requirements Width of fire separation adjacent to exterior wall | Fire-resistance rating of exterior wall or barrier | Fire-resistance rating of exterior opening protectives | Minimum classification of roof covering On lot lines of not less than 3 feet therefrom or from any building | 4 hour | Not permitted | B 3 feet or more but less than 6 feet | 3 hour | 3 hour | B 6 feet or more but less than 11 feet | 2 hour | 1½ hour | B 11 feet or more but less than 30 feet | 1 hour | ¾ hour | B 30 feet or more | 0 hour | 0 hour | C NOTE a. Not less than required by SBC-1, Table 401. The exterior wall or barrier shall extend to the height of the building and be so constructed that it will remain structurally in place for the duration of time indicated by the required fire-resistance rating. When the exterior wall or barrier is adjacent to a flat roof, it shall be constructed with a parapet. b. One foot equals 304.8 mm. (c) Storm enclosures. Storm enclosures may be erected of Type 2C or 5 construction not more than ten (10) feet (3048 mm) in height and not more than three (3) feet (914 mm) wider than the entrance doors which they serve, provided they do not project more than six (6) feet (1829 mm) beyond the building line. (d) Builders' shanties and reviewing stands. Temporary builders' shanties erected in connection with approved building operations, platforms, reviewing stands and other similar miscellaneous structures may be erected of Type 2C or 5 construction for a limited period of time as approved by the building official. (e) Bins, tanks, towers and roof structures. Coal and material bins, water towers, tank structures and trestles may be erected of Type 4 construction with dimensions not less than required for Type 4 construction, not over thirty-five (35) feet (10668 mm) in height when located thirty (30) feet (9144 mm) from the interior lot lines or any building, except when located on lot lines along a railroad right-of-way or waterfront. (f) Erection on buildings. Aerial supports not more than twelve (12) feet (3658 mm) in height, water tanks and flagpoles may be erected of wood on buildings not more than three (3) stories nor more than forty (40) feet (12192 mm) in height and drip bars in cooling towers may be constructed of wood. (g) Motor fuel service stations. Gasoline service stations, and structures of similar uses, not including use group H, may be erected of Type 2C construction within the height and area limits for use group M or SBC-1, Table 501, provided they are located not less than eleven (11) feet (3353 mm) from the lot line or another building. (h) Bus and passenger terminals. Roofs over parking lots, bus and passenger terminals may be erected one (1) story and not over twenty (20) feet (6096 mm) in height and not more than eleven thousand (11,000) square feet (1023 square meters) in area of Type 2C or 4 construction. (i) Wood veneers. Wood veneers of one-inch (25.4 mm) nominal thickness or exterior grade plywood not less than three-eighths ⅜ inch (9.53 mm) thick may be used on exterior wall when facing a fire separation of a minimum of thirty (30) feet (9144 mm) provided the veneer does not exceed one (1) story in height and is applied to noncombustible backing or is furred not to exceed 1⅝ inch (41 mm) and firestopped in accordance with SBC-1, Section 1420.0 and Section 1425.0. Where all wood veneers comply with SBC-1, Section 1043.5.2, for exterior use, the height may be increased to two (2) stories.

(Ord. 1985, Ch. 85-90, § 4, 12-24-85)

Ask a question about Providence law

Corpus searches the Providence sections it holds and shows the ones that match, with their citations. Free, no sign-in.