Sec. A.3. - Preliminary plat standards.

The following standards, which may from time to time be modified by the planning department, are required for any preliminary plat submittal: A.3.1. Lot layout. Dimensions of lot lines, lot numbers and lot area in square feet. A.3.1.1. Streets. Names, rights-of-way and roadway widths of existing streets and the location and proposed right-of-way width of existing and proposed street dedications. A.3.1.2. Location and type of existing utilities. A.3.1.3. Boundary lines. Bearing and distances from deed records or survey. A.3.1.4. Easements. Locations, width and purpose. A.3.1.5. Public sites. If any, to be reserved or dedicated for parks, playgrounds, or other public uses. A.3.1.6. Nonpublic sites. If any, for multi-unit dwellings, shopping centers, churches, industry or other nonpublic uses exclusive of single-family dwellings. A.3.1.7. Topographic information showing contour data at one foot intervals. A.3.1.8. Other conditions on the tract. Watercourses, flood plain and floodway boundaries and the 100-year flood elevation, marshes, wetlands, rock outcrops, wooded areas, isolated preservable trees two feet or more in diameter, groups of large (eight-inch dbh and greater) trees, and other significant features. A.3.1.9. Subsurface conditions on the tract. (If required by the city engineer) location and results of tests made to ascertain subsurface soil, rock and groundwater conditions; depth to groundwater unless test pits are dry at a depth of five feet. A.3.1.10. Other conditions on adjacent land. Approximate direction and gradient of ground slope, including any embankments or retaining walls; character and location of buildings located within 300 feet, railroads, power lines, towers, and other nearby nonresidential land uses or adverse influences; owner of adjacent unplatted land; for adjacent platted land refer to subdivision plat by name, recordation date, and number, and show approximately percent built-up, typical lot size, dwelling type. A.3.1.11. Minimum building setback lines. A.3.1.12. Zoning. On and adjacent to the tract. A.3.1.13. Vicinity Map. Showing location of the tract. A.3.1.14. Site data. Number of residential lots, site area, typical lot size, proposed uses and size of common open areas, parks, etc. A.3.1.15. Title, scale, north arrow and date. A.3.1.16. Subdivision name, name and address of owner, and name and address of individual or firm responsible for preparation of the plat. A.3.1.17. Where division of the property into phases or sections is contemplated, the proposed boundaries of such sections shall be shown and labeled and the sequence of development listed in alphabetic or numerical order. A.3.1.18. Traffic impact study/analysis will be required at the discretion of the public works department or when any proposed subdivision is expected to generate over 100 peak trips 500 trips in an average day. See Traffic Study Thresholds Table below. A.3.1.19. When required by the planning commission, the preliminary plat shall be accompanied by profiles showing existing ground surface and proposed street grades, including extensions for a reasonable distance beyond the limits of the proposed subdivision; typical cross sections of the proposed grading, roadway and sidewalk, and preliminary plan of proposed sanitary and storm sewers with grades and sizes indicated. All elevations shall be based on a datum plane approved by the city engineer. A copy of all plans and specifications so submitted and approved by the city engineer shall be maintained on file in the engineering department. A.3.1.20. Utility plan. Existing and proposed utilities on and adjacent to the tract. Location, size and invert elevation of sanitary and storm sewers; location and size of water mains, and fire hydrants. If water mains and sewers are not on or adjacent to the tract, indicate the direction and distance to, and size of nearest ones, showing invert elevation of sewers. Also, electric, gas, and cable utilities and any required retention/detention shall be shown. A.3.1.21. Grading and drainage plan. An overall grading plan shall be prepared showing existing and proposed contours at one foot intervals. Both existing and proposed contours shall be shown on the same drawing. An erosion control plan for the subdivision shall be prepared and submitted as part of the overall grading and drainage plan. A.3.1.22. Title and certificates. Present tract designation according to official records in office of appropriate recorder, title under which proposed subdivision is to be recorded, with names and addresses of owners, notation stating acreage, scale, north arrow, datum, bench marks, certification of registered civil engineer or surveyor, date of survey. A.3.1.23. Draft of protective covenants if the subdivider proposes to regulate land use in the subdivision and otherwise protect the proposed development. Traffic Study Thresholds Land Use | 100 Peak Trips | 500 Daily Trips Residential: Single-Family | 100 Units | 50 Units Apartments | 200 Units | 100 Units Condos/Townhouses | 200 Units | 100 Units Mobile Home Park | 300 Units | 100 Units Shopping Center | 15,500 square feet | 2,700 square feet Fast Food Restaurant (GFA) | 5,200 square feet | 1,200 square feet Convenience Store w/gas (GFA) | 1,200 square feet or 5 pumps Bank w/Drive-In | 4,400 square feet | 2,800 square feet Hotel/Motel | 250 rooms | 90 rooms General Office | 55,000 square feet | 45,000 square feet Medical/Dental Office | 37,000 square feet | 26,000 square feet Research and Development | 85,000 square feet or 4.5 acres | 70,000 square feet or 4 acres Light Industrial | 115,000 square feet or 8 acres | 115,000 square feet or 11.5 acres Manufacturing | 250,000 square feet | 195,000 square feet This table provides guidance on the type and scale of development that may generate 100 peak or 500 daily trips but is not intended to be a conclusive list.

Ask a question about Oxford law

Corpus searches the Oxford sections it holds and shows the ones that match, with their citations. Free, no sign-in.