Requirements for All Districts.
Austin City Code tit. 25, ch. 25-2, subch. C, art. 2, div. 2
in effectAustin City Code § 25-2-512 LOT SIZE MINIMUM.
§ 25-2-512 - LOT SIZE MINIMUM.
(A) Except as provided in Subsections (B) and (C), a lot may not be reduced in area, width, or depth to less than the minimum requirements.
(B) This subsection applies to the remainder of a lot if a portion of the original lot is acquired for public use. Notwithstanding other provisions of this article, the remainder of the lot complies with the lot size requirements of this article if:
(1) before the acquisition, the lot complied with the lot size requirements of this article;
(2) the remainder of the lot contains a rectangular space at least 30 feet by 40 feet in size and usable for a building, excluding required yards;
(3) the remainder of the lot contains an area that is not less than 50 percent of the minimum area requirement; and
(4) the remainder of the lot has at least 40 feet of street frontage.
(C) For a lot that is used exclusively for a public building, or by a public or quasi-public agency for a nonresidential use, the entity responsible under Chapter 25-5 (Site Plans) for approving a site plan for the use may reduce the lot size requirements of this article.
Source: Section 13-2-603; Ord. 990225-70; Ord. 031211-11.
Austin City Code § 25-2-513 OPENNESS OF REQUIRED YARDS.
§ 25-2-513 - OPENNESS OF REQUIRED YARDS.
(A) Except as otherwise provided in this section, a required yard must be open and unobstructed from finished grade to the sky. This restriction does not apply to a yard or part of a yard that is not required by this article.
(B) A window sill, belt course, cornice, flue, chimney, eave, box window, or cantilevered bay window may project two feet into a required yard. The two foot limitation does not apply to a feature required for a passive energy design.
(C) Uncovered steps or a porch or stoop that is not more than three feet above ground level may project three feet into a required yard.
(D) A parking area may be located in a required yard, unless prohibited by Article 10 (Compatibility Standards).
(E) In a townhouse and condominium residence (SF-6) or more restrictive district, a pool, including a swimming pool, reflecting pool, or fountain, may be located in a required yard.
(F) Landscaping may be located in a required yard.
(G) This subsection applies to a building located in a multifamily residence medium density (MF-3) or more restrictive district. A covered porch that is open on three sides may project five feet into a required front yard, a street side yard, or both.
(H) A ramp for a new or an existing single-family or duplex residential unit may be constructed in a required yard if:
(1) a person with a disability requires access to a dwelling entrance that meets the requirements of the Residential Code, Section R320.6 (Visitable dwelling entrance);
(2) the ramp:
(a) is no wider than 48 inches, except that any portion of a landing for the ramp required for turns may be no wider than 60 inches;
(b) may have a hand railing, but may not have a roof or walls; and
(c) the building official determines that the ramp will not pose a threat to public health and safety; and
(3) encroachment into the required yard:
(a) is the minimum amount necessary to provide access for a person with a disability;
(b) does not extend more than three feet into a side yard setback; and
(c) is not located in a rear yard setback unless:
(i) the dwelling is located on a corner lot;
(ii) access is from an alley; or
(iii) another requirement of this title prohibits location of the ramp in the front or side yard.
Source: Section 13-2-610; Ord. 990225-70; Ord. 031211-11; Ord. 040826-67; Ord. No. 20140522-078, Pt. 1, 6-2-14; Ord. No. 20151217-093, Pt. 1, 12-28-15.
Austin City Code § 25-2-514 (RESERVED).
Austin City Code § 25-2-515 REAR YARD OF THROUGH LOT.
§ 25-2-515 - REAR YARD OF THROUGH LOT.
For a through lot, a rear yard must comply with the minimum requirements applicable to a front yard.
Source: Section 13-2-612; Ord. 990225-70; Ord. 031211-11.
Austin City Code § 25-2-516 DEVELOPMENT NEAR A HAZARDOUS PIPELINE.
§ 25-2-516 - DEVELOPMENT NEAR A HAZARDOUS PIPELINE.
(A) In this section:
(1) HAZARDOUS PIPELINE means a pipeline designed for the transmission of a "hazardous liquid", as defined by Title 49, Code of Federal Regulations, Section 195.2, with an inside diameter of eight inches or more.
(2) NEW CONSTRUCTION means the construction after April 20, 2003 of a structure intended for human occupancy, and includes the construction of a new structure, the construction of an addition to an existing structure and the reconstruction of a portion of an existing structure. The term excludes an addition to or the reconstruction or replacement of a structure existing on April 21, 2003 used for:
(a) single-family residential use;
(b) small lot single-family residential use;
(c) single-family attached residential use;
(d) duplex residential use;
(e) two-family residential use;
(f) mobile home residential use; or
(g) in a neighborhood plan combining district:
(i) cottage special use;
(ii) urban home special use; or
(iii) secondary apartment special use.
(3) RESTRICTED PIPELINE AREA includes an area within 25 feet of a hazardous pipeline and an area within a hazardous pipeline easement.
(4) USE REQUIRING EVACUATION ASSISTANCE includes the following uses:
(a) congregate living;
(b) convalescent services;
(c) detention facilities;
(d) day care services (commercial);
(e) hospital (general);
(f) hospital (limited);
(g) medical offices exceeding 5,000 square feet of gross floor area;
(h) private primary educational facilities;
(i) private secondary educational facilities;
(j) public primary educational facilities;
(k) public secondary educational facilities; and
(l) retirement housing (large site).
(B) A use requiring evacuation assistance is prohibited in a structure intended for human occupancy that is located within 500 feet of a hazardous pipeline. This prohibition does not apply to a structure that is located between 200 and 500 feet of a hazardous pipeline if by resolution the council determines, after receiving a recommendation from the fire chief, that:
(1) the structure has a performance-based design that provides an adequate time period for occupant evacuation to a safe place in the event of a pipeline leak or fire associated with the pipeline, after considering:
(a) the requirements of Chapter 25-12, Article 7 (Uniform Fire Code) and the 2000 edition of the National Fire Protection Association 101 Life Safety Code;
(b) the site and structure design;
(c) the structure's building materials;
(d) the structure's distance from the pipeline;
(e) the use of radiant energy barriers;
(f) access to the site and the structure by emergency responders;
(g) available on-site resources for emergency responders;
(h) the topography and other natural features;
(i) the use of the structure; and
(j) the evacuation capability of the occupants;
(2) the structure incorporates a system for the early detection and notification of a pipeline leak, if the fire chief determines that an appropriate system is commercially available; and
(3) the performance-based design for occupant evacuation and the early detection and notification system are certified and sealed by an engineer registered in Texas.
(C) A person may not build new construction within 200 feet of a hazardous pipeline unless:
(1) the fire chief determines that:
(a) the new construction has a performance-based design that provides a minimum one-hour time period for occupant evacuation to a safe place in the event of a pipeline leak or a fire associated with the pipeline, in accordance with Chapter 25-12, Article 7 (Uniform Fire Code) or the 2000 edition of the National Fire Protection Association 101 Life Safety Code;
(b) the new construction incorporates a system for the early detection and notification of a pipeline leak, if the fire chief determines that an appropriate system is commercially available; and
(c) the performance-based design for occupant evacuation and the early detection and notification system are certified and sealed by an engineer registered in Texas; or
(2) the new construction complies with the standards for construction near a pipeline prescribed by the Fire Criteria Manual.
(D) A person may not place a structure or excavate within a restricted pipeline area.
(1) This prohibition does not apply to:
(a) the pipeline or an appurtenance;
(b) a facility that produces, consumes, processes, or stores the product transported by the pipeline, including a power generation facility;
(c) a utility line that crosses the restricted pipeline area, including an appurtenance to the line;
(d) a utility service connection;
(e) a road;
(f) a surface parking lot; or
(g) a structure or excavation that the director determines does not disturb the pipeline or impede its operation.
(2) Before a person may place a road, surface parking lot, or utility line in a restricted pipeline area, the person must deliver to the director a certification by a registered engineer stating that the proposed construction activity and structure are designed to prevent disturbing the pipeline or impeding its operation.
Source: Ord. 030410-12; Ord. 031211-11.
Austin City Code § 25-2-517 REQUIREMENTS FOR AMPHITHEATERS.
§ 25-2-517 - REQUIREMENTS FOR AMPHITHEATERS.
(A) Construction of an amphitheater that is associated with a civic or residential use requires a site plan approved under Section 25-5, Article 3 (Land Use Commission Approved Site Plans), regardless of whether the amphitheater is part of a principal or accessory use. Review of the site plan is subject to the criteria in Section 25-5-145 (Evaluation Criteria) and the notice requirements of Section 25-5-144 (Public Hearing and Notice).
(B) A decision by the Land Use Commission on an application for an amphitheater is subject to appeal under Section 25-5-149 (Appeal to Council).
(C) A lawfully constructed amphitheater may be expanded one time without obtaining the approval required under Subsection (A) of this section, provided that the expansion is consistent with the applicable site development regulations and does not expand the total area of the amphitheater by more than ten percent.
Source: Ord. 20130228-074.
Austin City Code § 25-2-518 QUALIFYING DEVELOPMENT.
§ 25-2-518 - QUALIFYING DEVELOPMENT.
(A) In this section, a qualifying development is a development certified under Section 25-1-724 (Certification) and participating in the Affordability Unlocked Bonus Program.
(B) Notwithstanding any ordinance or City Code provision to contrary, a qualifying development is a permitted use under Section 25-2-491 (Permitted, Conditional, and Prohibited Uses) in:
(1) a residential base zoning district;
(2) a commercial base zoning district;
(3) a special purpose base zoning district, except on a site designated:
(a) agricultural (AG),
(b) aviation (AV); or
(4) a combining and overlay district.
(C) No more than 25 percent of the gross floor area of the qualifying development may be comprised of commercial uses. The permitted commercial uses are determined using the base zoning district.
(D) A qualifying development is not required to comply with:
(1) the height and setback requirements of Article 10 (Compatibility Standards) except to maintain side setbacks as required by the base zoning district;
(2) the maximum floor-to-area ratio for the applicable base zoning district under Section 25-2-492 (Site Development Regulations);
(3) Subchapter F (Residential Design and Compatibility Standards) except to maintain side setbacks as required by the base zoning district;
(4) Section 25-2-773 (Duplex, Two-Unit and Three-Unit Residential Uses); or
(5) minimum site area requirements.
(E) This subsection applies to a qualifying development located in urban residence (SF-5) or more restrictive zoning district and the height of the development exceeds 35 feet or three stories.
(1) A qualifying development must comply with:
(a) Section 25-2-1066 (Screening Requirements); and
(b) Subsections (A) and (B) in Section 25-2-1067 (Design Regulations).
(2) A person must enclose a refuse receptacle, including a dumpster.
(3) The location of and access to a refuse receptacle is subject to review and approval by the accountable official.
(4) A person may not collect or allow another to collect refuse receptacles between 10:00 p.m. and 7:00 a.m.
Source: Ord. No. 20190509-027, Pt. 3, 5-20-19; Ord. No. 20231207-001, Pt. 18, 12-18-23.
Austin City Code § 25-2-519 RESERVED
Source: City of Austin, City Code and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/tx/austin/codes/code_of_ordinances?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART2PRUSDERE_DIV2REALDIFetched: 10/27/2026