Sec. 37-156. - Sampling and analytical requirements.
(1) Except as indicated in subsections (2) and (3) below, the user must collect wastewater samples using twenty-four-hour flow proportional composite sampling techniques, unless time proportional composite sampling or grab sampling is authorized by the pretreatment coordinator assigned/designated by the director of public works. Where time proportional composite sampling or grab sampling is authorized by [the city], the samples must be representative of the discharge. Using protocols (including appropriate preservation) specified in 40 CFR Part 136 and appropriate EPA guidance, multiple grab samples collected during a twenty-four-hour period may be composited prior to the analysis as follows: For cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected but authorized by [the city], as appropriate. In addition, grab samples may be required to show compliance with instantaneous limits. (2) For sampling required in support of baseline monitoring, ninety-day compliance reports, for new users, for existing users that make changes or install new treatment or existing users for which historical data does not exist or does not represent current discharge conditions, required under 40 CFR 403.12(b) and (d), a minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the director of public works may authorize a lower minimum. For the reports required by 40 CFR 403.12(e) and (h), the director of public works shall require the number of grab samples necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. (3) Samples shall be taken immediately downstream from pretreatment facilities if such exist, immediately downstream from the regulated or manufacturing process if no pretreatment exists, or at a location determined by the city and specified in the user's wastewater discharge permit. For categorical users, if other wastewaters are mixed with the regulated wastewater prior to pretreatment, the user shall measure the flows and concentrations necessary to allow use of the combined waste stream formula of 40 CFR § 403.6(e) in order to evaluate compliance with the applicable categorical pretreatment standards. For other SIUs, for which the city has adjusted its local limits to factor out dilution flows, the user shall measure the flows and concentrations necessary to evaluate compliance with the adjusted pretreatment standard(s). (4) All sample results shall indicate the time, date and place of sampling and methods of analysis and shall certify that the waste stream sampled is representative of normal work cycles and expected pollutant discharges from the user. If a user sampled and analyzed more frequently than what was required in its wastewater discharge permit, using methodologies in 40 CFR Part 136, it must submit all results of sampling and analysis of the discharge as part of its self-monitoring report. (5) All pollutant analyses, including sampling techniques, shall be performed in accordance with the techniques prescribed in 40 CFR Part 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 CFR Part 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance with procedures approved by the EPA. (6) The control authority is required to document site-specific circumstances and allow alternative sampling by including the alternate sampling by including the alternate sampling in the IU control mechanism. The control authority is required to document how alternate sampling are representative of the discharge. The control authority is authorized to require that more than four (4) grab samples be taken and analyzed to ensure that sampling is representative. Where the control authority cannot verify that previous techniques were representative, such data will not support the use of alternative sampling practice.
(Ord. No. 09-277, § 12-29-09; Ord. No. 20-044, § 2, 4-21-20)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.