§ 14.04.120 — Section 1807.3.1 of the 2025 Edition of the California Building Code is amended to read as follows
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.120
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/2e5c8b60-6cf7-48ab-9454-ab04adf7469e
14.04.120 - Section 1807.3.1 of the 2025 Edition of the California Building Code is amended to read as follows.
1807.3.1 Limitations. The design procedures outlined in this section are subject to the following limitations: 1. The frictional resistance for structural walls and slabs on silts and clays shall be limited to one-half of the normal force imposed on the soil by the weight of the footing or slab. 2. Posts embedded in earth shall not be used to provide lateral support for structural or nonstructural materials such as plaster, masonry or concrete unless bracing is provided that develops the limited deflection required. Wood poles shall be treated in accordance with AWPA U1 for sawn timber posts (Commodity Specification A, Use Category 4B) and for round timber posts (Commodity Specification B, Use Category 4B). Wood poles and posts embedded in direct contact with soil shall not be used for structures assigned to Seismic Design Category D, E or F. Exception: Wood poles and posts embedded in direct contact with soil may be used to support nonhabitable, nonoccupiable structures such as fences when approved by the building official.
(Ord. No. 7461, § 5, 11-10-2025)