§ 5-1-141 - BUILDING ENTRANCES.
(A) Habitable space in a dwelling unit located on the first story must include at least one building entrance on the first story served by a ramp or no-step entrance. A building entrance door must have a minimum net clear opening of 32 inches. (B) The building entrance may be at the front, side, or back of a dwelling provided it is served by an accessible route, including a walking surface from a garage, ramp, sidewalk, or public right-of-way that is within 200 feet of the building entrance. (C) If a building entrance includes a no-step entrance, the maximum distance between the interior floor level of the building entrance and the adjacent walking surface level may be no greater than one-half inch.
Source: 1992 Code Section 7-1-181; Ord. 031106-12; Ord. 031211-11; Ord. 040115-45; Ord. 040610-7; Ord. 20050623-134.