Pretreatment standards.
Round Rock Code of Ordinances § 44-82
in effectSec. 44-82. - Pretreatment standards.
(a) There are three types of pretreatment standards: prohibited discharge standards, including general, specific, and dilution prohibitions; national categorical standards; and local limits. These standards shall apply to a user whether or not the user is subject to other federal, state, or local requirements.
(b) The standards in this subsection shall apply to each user, as applicable. Users in an industrial manufacturing category specified in 40 CFR (I)(N), "Effluent Guidelines and Standards," shall be subject to prohibited discharge standards, national categorical standards, and local limits. Other users shall be subject to prohibited discharge standards and local limits. Where these standards overlap, the most stringent standard shall apply to the user.
(c) The control authority, at his discretion, has the right to apply these standards to individual nondomestic discharges before they are commingled.
(d) Prohibited discharge standards.
(1) General prohibitions. A user may not discharge to the POTW any material which causes pass-through or interference.
(2) Specific prohibitions. The following shall not be discharged to the POTW:
a. Discharges which are capable of creating a fire or explosion hazard in the POTW. These discharges include, but are not limited to, discharges with a closed cup flashpoint of less than 140 degrees Fahrenheit, as determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM (American Society for Testing and Materials) standard D-93-79 or D-93-80K or a Seta flash Closed Cup Tester, using the test method specified in ASTM standard D-3278-78;
b. Discharges which will cause corrosive structural damage to the POTW, but in no case discharges with pH lower than 5.5 or greater than 9.5;
c. Discharges containing:
1. Solid or viscous materials in amounts which will cause obstruction to the flow in or proper operation of the POTW resulting in interference;
2. Any materials such as wax, grease, oil, or plastics that will solidify or become discernibly viscous at temperatures between 32 and 150 degrees Fahrenheit;
3. Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through;
4. Any materials such as ashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, whole blood, paunch manure, hair and fleshings, entrails, lime slurry, lime residues, slops, chemical residues, paint residues or bulk solids in such quantities capable of causing interference with the POTW; or
5. Any fats, oils, greases or similar materials in excess of a daily average limit of 200 mg/l using approved methods for fats, oils and greases.
d. Discharges having a temperature higher than 150 degrees Fahrenheit and 65 degrees Celsius, or any discharge which contains heat in amounts which will inhibit biological activity or cause interference with the POTW, but in no case heat in such quantities that the temperature at the headworks of the POTW exceeds 104 degrees Fahrenheit and 40 degrees Celsius;
e. Discharges that contain any noxious or malodorous materials which can form a gas; which, either singly or by interaction with other discharges, are capable of causing objectionable odors or hazard to life; which creates any other condition deleterious to the POTW; or which requires unusual provisions, attention, or expense to handle;
f. Discharges which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute workers health and safety problems;
g. Discharges that are capable of causing excessive discoloration in the POTW effluent;
h. Discharges with unusual flow and concentration, including those with oxygen demanding materials, at a flow rate or concentration which will cause interference with the POTW, or, if such materials can cause damage to collection facilities, impair the treatment processes, incur excessive treatment cost, or cause the city to be noncompliant with the conditions of its discharge permits;
i. Discharges containing a BOD or TSS concentration in excess of 7,000 mg/L;
j. Discharges classified by the TCEQ as hazardous waste at 31 TAC 335 without the written approval of the control authority;
k. Discharges containing radioactive materials without the written approval of the control authority;
l. Materials that are trucked or hauled in, except at discharge points that are designated by the control authority;
m. Discharges from steam cleaning and chemical cleaning businesses unless a facility or process is provided that will produce an effluent compliant applicable pretreatment requirements. There shall be no discharge of visible foam; or
n. Stormwater, surface water, ground water, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, noncontact cooling water, and unpolluted wastewater, unless specifically authorized by the control authority.
(3) Dilution prohibitions.
a. No user shall ever add any material, either liquid or nonliquid, or in any other way attempt to dilute a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the national categorical standards or local limits.
b. This prohibition does not include dilution which is a normal part of the production process or a necessary part of the process to treat a waste, such as adding lime for neutralization or precipitation, or the mixture of compatible wastes in order to treat at capacity levels rather than treating wastes in small batches.
c. The control authority, at his discretion, may impose mass limitations on a user that is using dilution to meet applicable pretreatment standards or requirements, or in cases where the imposition of mass limitations is appropriate.
(e) National categorical standards.
(1) National categorical standards apply to specific industrial subcategories under 40 CFR (I), (N), "EPA Effluent Guidelines and Standards." A user that falls into one of these subcategories shall be subject to the pretreatment standards applicable to that subcategory and is classified as a categorical user.
(2) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the control authority shall impose an alternate limit in accordance with 40 CFR 403.6(e).
(f) Local limits. Local limits are quantitative limits on discharges applicable to all users. Local limits are designed to meet the general and specific prohibitions in this article.
(1) Existing local limits. Local limits are periodically reviewed by the control authority and revised as necessary to respond to changes in federal, state, or local regulations, environmental protection criteria, plant design and operational criteria, and the nature of industrial discharges to the POTW. Local limits are as follows:
Constituent* | Maximum Allowable Concentration in a Daily Composite, mg/L
Arsenic | 0.43
Cadmium | 0.09
Chromium | 10.7
Copper | 1.93
Cyanide | 0.4
Lead | 0.57
Manganese | 52.7
Mercury | 0.0**
Molybdenum | 1.07
Nickel | 3.69
Phosphorus | 14.88
Selenium | 0.17
Silver | 0.71
Zinc | 1.8
Notes:
* Limits for metal based on unfiltered samples.
** ;hg;Compliance shall be measured at the minimum analytical level (MAL) of 0.0002 mg/L).
(2) Case-by-case local limits. Local limits that have not yet been established for a material may be developed on a case-by-case, user specific basis. A user must have the case-by-case local limits included in a permit before discharging to the POTW.
(3) The above limits apply at the point where the wastewater is discharged to the POTW.
(Code 1995, § 10.403; Ord. No. O-2020-0222, §§ I, II, 8-13-2020)