Sec. 16-6.02.090: - Amendment to Section 307.1 General

Section 307.1 is amended to read as follows: Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall not be less than 34 inches (864 mm) high or more than 38 inches (965 mm) high measured vertically above the nosing of the tread or above the finished floor or the landing or walking surfaces. Guards shall not be less than 42 inches (1067 mm) high above the floor or the landing, balcony, porch, deck or ramp or other walking surface. Exception: Guards shall not be required where exempted by the adopted Current California Building Code

(Ord. No. 2303, § 1, 12-3-13)