§ 13-59 — Plans, permits and fees

Code of Ordinances, City of Burlington, Vermont (Current through Ord. 8-3-26, passed August 3, 2026) · Burlington Code of Ordinances § 13-59

Corpus is an independent public-information project, not the official City of Burlington website. Stable reference: corpuslaw.us/code/32117811-d2f0-4b8a-83c7-1776b0829578

13-59 Plans, permits and fees.

(a) Submission. Plans for fire prevention, protection, and alarm systems shall be submitted to the fire marshal for approval prior to any work being done. The fire marshal shall have up to thirty (30) business days to review plans, make inspections, and issue a permit for the system, which may upon notification to the applicant be extended. Plans may be approved, rejected or be required to be amended. No plan shall be approved or permit issued unless all fees have been paid and satisfied. Plans shall be submitted in either paper or electronic formats (PDF). (b) Required information. Fire prevention, protection, and alarm system plans shall include the floor plan with device locations, the wiring riser diagram, battery load calculations, the complete equipment list and specifications, the type of occupancy, hazards, or unusual building features, and any other information required by the Vermont Fire and Building Safety Code as currently adopted by the State of Vermont. (c) Fees. The fire marshal shall receive the following fees for plan review and inspections: (1) Specialty suppression systems. Fees for plan review, rough-in inspection, and the final inspection shall be eleven dollars ($11.00) per one thousand dollars ($1,000.00) of the final contracted costs for systems containing proprietary blended inert gasses arranged in single or manifold pressurized cylinders, delivered through piping, and exhausted under pressure from a distribution appliance. Additional permitting, review and inspection fees may be applicable. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is eleven dollars ($11.00). (2) Hood suppression systems. Fees for plan review, rough-in inspection, and the final inspection shall be forty dollars ($40.00) per one thousand dollars ($1,000.00) of the final contracted costs for hood suppression systems containing a proprietary blend of dry chemicals or wet agent arranged in single or manifold pressurized cylinders, delivered through piping and exhausted under pressure from a distribution appliance. Additional permitting, review and inspection fees may be applicable. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is forty dollars ($40.00). (3) Fire sprinkler systems. Fees for plan review, rough-in inspection, and the final inspection shall be eighteen dollars ($18.00) per one thousand dollars ($1,000.00) of the final contracted costs for sprinkler, standpipe, and fire pump systems as those systems are defined in NFPA 13, NFPA 14 and NFPA 20. Additional permitting, review and inspection fees may be applicable. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is eighteen dollars ($18.00). Residential sprinkler systems (NFPA 13R), installed in residential properties of less than five (5) units, with the exception of an expedited permit, shall have the fee waived. (4) Fire alarm systems. Fees for permit review, rough-in inspection, and the final inspection shall be thirty-one dollars ($31.00) per one thousand dollars ($1,000.00) of the final contracted costs for fire alarm systems, as they are defined in NFPA 72. Additional permitting, review and inspection fees may be applicable. Wireless smoke alarms installed in residential properties of less than eleven (11) units, with an associated control/monitoring/reset panel, shall be considered a fire alarm system. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is thirty-one dollars ($31.00). (5) Standpipe systems. Fees for plan review, rough-in inspection, and the final inspection shall be eighteen dollars ($18.00) per one thousand dollars ($1,000.00) of the final contracted costs for standpipe systems as those systems are defined in NFPA 13, NFPA 14 and NFPA 20. Additional permitting, review and inspection fees may be applicable. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is eighteen dollars ($18.00). (6) Fire pump systems. Fees for plan review, rough-in inspection, and the final inspection shall be seven dollars ($7.00) per one thousand dollars ($1,000.00) of the final contracted costs for sprinkler, standpipe, and fire pump systems as those systems are defined in NFPA 13, NFPA 14 and NFPA 20. Additional permitting, review and inspection fees may be applicable. The fee for the review of an amendment to a plan shall be fifty dollars ($50.00) per amendment submission plus three (3) percent of the increase in the net cost of the final contracted cost of the system. The minimum fee for work values less than or equal to one thousand dollars ($1,000.00) is seven dollars ($7.00). (7) Reinspection fees. A fee for the witnessing of a retest of any fire protection, prevention, or alarm system or the reinspection of a system or any part thereof beyond the rough-in inspection and the final inspection shall be charged at a rate of seventy-five dollars ($75.00) per hour per inspector. This fee is payable by installing contractor prior to any retest. (8) Expedited process fees. Plans for systems with contracted costs valued at less than twenty thousand dollars ($20,000.00) may be reviewed and approved on an expedited process within ten (10) business days for a special fee of one hundred fifty dollars ($150.00) per hour paid in addition to all the applicable permitting fees. (9) Phased-in installation inspection fees. An additional fee of twelve (12) percent of the system permit fee shall be charged and paid when a permittee requests to phase in a system and inspections are required and conducted for each phase. (10) City-owned properties. No fee shall be required for the portion of the estimated cost of any work and construction that is to be owned by a department of the City of Burlington whose primary source of revenue is the general fund.

(Ord. of 2-22-93; Ord. of 10-16-00; Ord. of 6-26-06/7-26-06; Ord. of 10-26-09(1); Ord. of 6-25-18(1))

Ask a question about Burlington law

Corpus searches the Burlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.