§ 8.14.060 — Grease interceptor requirements

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 8.14.060

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/322afb00-97e9-4446-898f-919a2c2a210f

8.14.060 - Grease interceptor requirements.

Grease interceptors shall conform with the following standards: A. Grease interceptor sizing and installation shall conform to the requirements in the 1998 California Plumbing Code. B. Grease interceptors shall be constructed in accordance with a design approved by the city engineer and shall have a minimum of two compartments with fittings designed for grease retention. C. Grease interceptors shall be installed at a location easily accessible for inspection, cleaning, and removal of intercepted grease. The grease interceptor shall not be installed in any part of the building where food is handled. The location of the grease interceptor must be approved by the city engineer. D. All such grease interceptors shall be serviced and emptied of accumulated waste contents as required in order to maintain minimum design capacity or effective volume. These devices must be inspected at least monthly. E. Users who are required to main a grease interceptor shall provide for a minim hydraulic retention time in accordance with the 1998 California Plumbing Code, and remove any accumulated grease cap and sludge pocket as required. F. Grease interceptors shall be kept free of inorganic solid materials such as grit, rocks, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., which could settle into the sludge pocket and thereby reduce the effective volume of the device. G. The grease interceptor user shall maintain a written record of inspection and maintenance for three (3) years. All such records shall be made available for on-site inspection by enforcement officials during all business operating hours. H. Sanitary wastes shall not be allowed to be connected to sewer lines intended for grease interceptor service. I. Users shall provide access manholes, with a minimum diameter of 24 inches, over each grease interceptor chamber and sanitary tee. The access manholes shall extend at least to finished grade and be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, grease removal, and wastewater sampling activities.

(Ord. 6893 § 2 (part), 2002)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.