For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-20 — Amendments to the International Mechanical Code

Code of the City of Glendale, Arizona (Supp. No. 115: codified through Ordinance No. O26-19, adopted April 14, 2026) · Glendale City Code § 9-20

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/34a87441-3973-4eba-9292-d1460e251f6c

Sec. 9-20. - Amendments to the International Mechanical Code.

Section 101.1 Title. Revise to read as follows: These regulations shall be known as the Mechanical Code of the City of Glendale, Arizona, hereinafter referred to as "this code." Chapter 1 is amended by the deletion of Sections R102 through R115. For the administration of this code, see the 2024 International Building Code and related amendments. Section 307.2.1 Condensate disposal is amended by adding the following: Condensate drain piping shall not terminate over sidewalks, asphalt, concrete, walking surfaces or similar surfaces. All condensate drain piping shall terminate in an approved location as determined by the building official or his representative. Section 408, Marijuana Related Occupancies, add this section: 408 Marijuana Related Occupancies 408.1 General. Any building used to cultivate, produce, infuse or dispense marijuana shall be designed such that there shall be no emission of dust, fumes, vapors, or odors into the environment from the premise. A ventilation system shall be designed to prevent the distribution of odors to other occupied parts of the building or adjacent properties. Design of the odor control system shall be based on accepted engineering practices. All equipment and filter media shall be listed and labeled for the application. Exhaust systems used in odor control systems shall meet the requirements of Section 501. 408.1.1 Exhaust outlets. The termination point for exhaust outlets shall be in accordance with Section 501.3. Exhaust from cultivation and production facilities shall be in accordance with Section 501.3.1(2) and for dispensaries in accordance with Section 501.3.1(3). Section 607.2 Installation is amended to read as follows: Fire dampers, smoke dampers, combination fire/smoke dampers and ceiling radiation dampers located within air distribution and smoke control systems shall be installed in accordance with the manufacturer's instructions, the dampers' listing and Sections 607.2.1 through 607.2.3. Dampers shall be tested by an approved testing agency or a qualified third- party special inspector. The special Inspector/testing agency shall be an independent third- party individual or firm and shall not be the installing contractor. Special inspections shall be as specified in Chapter 17 of the International Building Code. Section 928, Evaporative Cooling Equipment, add the following subsection: Section 928.2 Water conservation. Evaporative cooling systems shall be provided with a recirculating water system. Any bleed off rate used by the system shall be limited to that recommended by the manufacturer. Once-through evaporative cooling systems using potable water shall not be permitted. Section 932, add this new section to read as follows: Section 932 Water-cooled refrigeration/heat removal systems. 932.1 Water conservation. A water-cooled refrigeration system or heat removal system, (defined as refrigeration or heat removal system using water, all, or in part, for condensing a refrigerant), shall not discharge more than three gallons of water per nominal ton per hour into an approved sanitary disposal system. Condenser wastewater discharge shall be accomplished by the use of an air gap, as described in the International Plumbing Code. Each water-cooled system shall be provided with one or more of the following water-saving devices: (a) a cooling tower: or (b) an evaporative condenser; or (c) an approved water circulating device.

(Ord. No. O25-51, § 1, 12-9-25)

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.