Sec. 2304. - Minimum front, side and rear yards.
2304.1. Except as hereinafter provided, no structure or building shall be set back a lesser distance from the street line than that shown in Table No. 1, Dimensional Requirements, for the district in which it is located.
Except as hereinafter provided, no building or structure shall have a lesser side or rear yard than that shown in Table No. 1, Dimensional Requirements for the district in which it is located; provided, the setback lines contained in the ordinance shall not apply to any fence, wall, or hedge used to mark all or part of the boundary of any lot, except as provided in section 506.
Section 2304.2. Frontage in cul-de-sacs: Lots in a cul-de-sac, with more than fifty (50) percent of the lot area that falls within the cul-de-sac, the minimum frontage may be applied along the arc distance at the setback line in lieu of the lot line as long as the general aesthetic conforms to the overall layout of the subdivision as determined by the city engineer. When fifty (50) percent or less of a lot area is within a cul-de-sac, the required frontages shall be measured from the front lot line.
;mb=8q;Minimum requirements ;mb=8q;per dwelling unit | ;mb=20q;Minimum setback ;mb=20q;to street line | ;mb=24q;Minimum Yard | ;mb=30q;Maximum Height
District | Lot frontage or width (feet) | Lot area (sq. ft. or acres) | Floor area (sq. ft.) | Maximum lot covered by buildings (a) (gross) | Minor and collector (feet) | Major (feet) | Side (feet) | Rear (feet) | (stories) | (feet)
R-1 (Residential) One-Family | 90(n) | 12,000 | 1,200(i) | 30% (b) | 40(c), (d) | 50(c), (d) | 10(d), (g) | 35(d) | 2½ | 35(e)
R-1A (Residential) One-Family | 200(n) | 1 acre | 1,200(i) | 20% (b) | 90(c), (d) | 100(c), (d) | 25(d), (g) | 85(d)
R-2 (Residential) One-Family | 80(n) | 10,000 | 1,000(i) | 30% (b) | 35(c), (d) | 45(c), (d) | 10(d), (g) | 30(d) | 2½ | 35(e)
R-2A (Residential) One-Family | 80(n) | 10,000 | 1,000(i) | 30% (b) | 35(c), (d) | 45(c), (d) | 10(d), (g) | 30(d) | 2½ | 35(e)
Two-Family | 40(n) | 6,000 | 700(i) | 30% | 35(c), (d) | 45(c), (d) | 10(d), (g) | 30(d) | 2½ | 35(e)
Multifamily | 120(h), (n) | 2,750 | 500(i) | 30% (b) | 40(c), (d) | 50(c), (d) | 25(d), (g), (1) | 35(d)
R-3 (Residential) One-Family | 70(n) | 9,000 | 900(i) | 30% (b) | 30(c), (d) | 40(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
Two-Family | 40(n) | 6,000 | 700(i) | 30% (b) | 30(c), (d) | 40(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
R-4 (Residential) One-Family | 60(n) | 5,000 | 800(i) | 35% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
Two-Family | 35(n) | 3,500 | 650(i) | 35% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
Multifamily | 80(h), (n) | 2,250 | 400(i), (m) | 35% (b) | 30(c), (d) | 40(c), (d) | 15(d), (g), (1) | 30(d)
R4-A (Residential) Mobile home parks | (DNA) | (DNA) | (DNA) | (DNA) | 25(c), (d) | 35(c), (d) | 20(d), (g) | 20(d) | 2½ | 35(e)
Mobile home subd. | 60(n) | 5,000 | 500(i) | 40% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
R-5 (Residential) One-Family | 60(n) | 5,000 | 600(i) | 40% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
Two-Family | 30(n) | 3,500 | 500(i) | 40% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d) | 2½ | 35(e)
Multifamily | 80(h), (n) | 2,250 | 400(i), (m) | 40% (b) | 30(c), (d) | 40(c), (d) | 15(d), (g), (1) | 30(d)
A-1 (Residential) One-Family conventional housing subd. individual conventional dwellings, mobile home subd. and individual mobile home units (public approved sewer not available) | 150(n) | 1 to 3 acres (j) | 900(i) | 20% (b) | 40(c), (d) | 50(c), (d) | 15(d), (g) | 50(d)
One-Family Conventional Housing subd. (public approved sewer available) | 80(n) | 10,000 | 1,000(i) | 30% (b) | 35(c), (d) | 45(c),(d) | 10(d), (g) | 30(d)
One-Family mobile home subd. (public approved sewer available) | 60(n) | 5,000 | 500(i) | 40% (b) | 25(c), (d) | 35(c), (d) | 10(d), (g) | 25(d)
C-1 Neighborhood Business | 40% (b) | 65(c), (d) | 70(c), (d) | 10(d), (f), (g) | 30(d), (f)
C-2 Residential Business District | 40% (b) | 65(c), (d) | 70(c), (d) | 10(d), (f), (g) | 30(d), (f)
C-3 Central Business District | 100% (b) | none required | none required | none required 10 ft. when abutting residential (d), (f)
C-4 General Commercial District | 50% (b) | 45(c), (d) | 50(c), (d) | 10(d), (f), (g) | 15(d), (f)
I-1 Light Industrial District | 50% (b) | 65)(c), (d) | 70(c), (d) | 15(d), (g), (k) | 30(d), (k)
I-2 Heavy Industrial District | 50% (b) | 65(c), (d) | 70(c), (d) | 15(d), (g), (k) | 30(d), (k)
(DNA) [Does not apply.]
(a)
Includes principal and accessory buildings.
(b)
Provided that the parking and loading requirements of article XXV are met.
(c)
See section 2403. (Front yard setbacks.)
(d)
Front, side and rear yards may be used for parking or loading to within five (5) feet of property line. Driveways may be constructed up to the property line.
(e)
May be exceeded subject to limits established by section 2404. (Exceptions to height limits.)
(f)
None required between two (2) or more buildings on contiguous lots, provided said buildings are constructed with a common wall meeting fire limit requirements or provided that one (1) building may cross one (1) or more property lines.
(g)
Corner lots or lots formed at the intersection of two (2) streets shall not be required to provide two (2) front yard setbacks. Only on one (1) side abutting either street shall the front setback be required. On the remaining side, a setback of one-half (½) the otherwise required front setback shall be provided.
(h)
Total minimum lot frontage or width for the apartment or multifamily complex.
(i)
Includes heated floor area only.
(j)
In accordance with Circular Letter No. 164, issued by the Mississippi State Board of Health concerning "Policies and Procedures Relating to Residential Sewage Disposal Systems," areas where a properly made soil test on the lot fails to show a satisfactory percolation rate, the minimum lot size shall be three (3) acres provided all additional specifications required by the Washington County Health Department are complied with.
(k)
One hundred (100) feet when abutting any residential zone.
(l)
Separation between any two (2) buildings within a multifamily complex shall be a minimum of twenty (20) feet provided the building code is complied with.
(m)
Efficiency apartment units of between three hundred (300) and four hundred (400) square feet in size will be conditioned upon a requirement of single occupancy.
(n)
For frontage in cul-de-sacs in residential and agricultural districts, see section 2304.2.
(Two Ords. of 9-1-81, § 1; Ord. of 3-1-83, § 1; two Ords. of 6-7-83, § 1; Ord. of 11-1-83, § 1; Ord. No. 88-0015, § 1, 8-2-88; Ord. No. 00-0007, § I, 6-6-00)