§ 2245 — Policy
Land Development Code, City of Coral Springs, Florida (Supp. No. 76, Update 2: codified through Ordinance No. 2025-119, enacted December 3, 2025) · Coral Springs Land Development Code § 2245
Corpus is an independent public-information project, not the official City of Coral Springs website. Stable reference: corpuslaw.us/code/35061ff9-d9b9-4ae8-be37-c538745cdd18
Sec. 2245. - Policy.
(1) No water service connection to any premises shall be installed or maintained by the water purveyor unless the water system is protected as required by state laws, regulations and this article. Service of water to any premises shall be discontinued by the water purveyor if an approved backflow prevention assembly required by this article is not installed, tested, certified, maintained, or if it is found that a backflow prevention assembly has been removed, bypassed, or if an unprotected cross connection exists on the premises. Service shall not be restored until such conditions or defects are corrected. (2) The customer shall be open for inspection at all reasonable times to authorized representatives of the Coral Springs Utilities and Building Divisions, the Broward County Public Health Unit and any other officials with jurisdiction to determine whether cross connections or other structural or sanitary hazards, including violations of the provisions of this article, exist. Water service may be discontinued after notice to the owner if a violation of this article exists on the premises and such other precautionary measures may be taken as are deemed necessary to eliminate any danger to the potable water. Water service shall not be restored until the danger has been eliminated in compliance with the provisions of this article. (3) An approved backflow prevention assembly shall also be installed, at the customer's expense, on each service line to a customer's system at or near the property line or immediately outside the building being served; but, in all cases, before the first branch line leading off the service line wherever the following conditions exists: (a) In the case of premises having any auxiliary water supply, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard, as described in sections 2245(4) and (6). (b) In the case of premises on which any auxiliary water supply of industrial fluids system is utilized, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard, as described in section 2245(5). (c) In the case of premises having internal cross connections that can not be permanently corrected and controlled, intricate plumbing and piping arrangements, or where entry to all portions of the premises is not readily accessible for inspection services, making it impracticable or impossible to ascertain whether or not dangerous cross connections exist, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard, as described in section 2245(5). (d) In case of fire protection systems, see section 2245(6). (4) The type of protective device required, under sections 2245(3)(a), (b) and (c,) shall depend upon the degree of hazard which exists as follows: (a) In the case of any premises where there is an auxiliary water supply as stated in this section, and it is not subject to sections 2245(4)(b), (c), (d), (e) and (f), the utility system shall be protected by an approved air-gap separation or a reduced-pressure backflow prevention assembly. (b) In the case of any premises where a non-health hazard exists, these systems shall be protected by a double check valve assembly. (c) In the case of any premises where there is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the utility system, the utility system shall be protected by an approved air-gap separation or a reduced-pressure backflow prevention assembly. (d) In the case of any premises where there are either actual or potential cross connections, the utility system shall be protected by an approved backflow prevention on the exterior water faucets, and an approved air-gap separation or a reduced-pressure backflow prevention assembly at the water service connection. The type of backflow prevention assembly shall be determined by the level and degree of hazard as outlined in section 2245(3) of this article. (e) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross connection survey, the utility system shall be protected against backflow or backsiphonage from the premises by an approved air-gap separation or a reduced-pressure backflow prevention assembly at each water service connection to the premises. (f) In the case of any premises where a health threat is posed because of the presence of extremely toxic substances, an air-gap separation at the water service connection shall be required. (5) A backflow prevention assembly of the type designated shall be installed on each water service connection to the following types of facilities. This list is presented as a guideline with respect to the facilities listed and is not to be construed as being complete: Abbreviations are as follows: A.G. | Air-Gap Separation R.P. | Reduced-Pressure Backflow Prevention Assembly D.C.V.A. | Double Check Valve Assembly P.V.B. | Pressure Vacuum Breaker A.V.B. | Atmospheric Vacuum Breaker TITLE TYPE OF FACILITY | MINIMUM TYPE OF PROTECTION Breweries, Distilleries, Bottling plants | R.P. Buildings over three (3) stories | R.P. Car wash with recycling system and/or wash educator | R.P. Chemical plants | R.P. Dairies | R.P. Dentist office(s) | R.P. Fertilizer plants | R.P. Film laboratory or Processing plant | R.P. Food or Beverage plant | R.P. Hospitals, Clinics, Medical buildings | R.P. (Parallel) Irrigation systems | R.P. or P.V.B. Laboratories | R.P. Laundries and Dry Cleaning plants | R.P. Machine Tool plants (health or system hazard) | R.P. Machine Tool plants (pollution hazard) | R.P. Metal Processing plant (health or system hazard) | R.P. Metal Processing plant (pollution hazard) | R.P. Metal Plating plant | R.P. Morgues or Mortuaries | R.P. Nursing Homes | R.P. Packing houses or Rendering plants | R.P. Paper Products plants | R.P. Pesticides (Exterminating Companies) | A.G. Pharmaceutical or Cosmetic plant | R.P. Piers, Docks or Waterfront facilities | R.P. Power plants | R.P. Radioactive Material plants | R.P. Restaurant | R.P. Sand and Gravel plants | R.P. Schools | R.P. Shops (Retail and Wholesale) | R.P. Swimming pools with piped fill line | A.G. at pool Sewage pumping stations | R.P. Sewage treatment plants | R.P. Veterinary establishments | R.P. (6) Due to the variety of installation designs of fire systems which may preclude the use of a meter, the point of service shall be defined as the last valve prior to the outside stem and yoke (OS&Y) valve. A backflow prevention assembly of the type designated below shall be installed on the water service to any premises. Fire protection systems are divided into six (6) general classes. The following are typical: Minimum Type of Protection Class 1 | A closed automatic fire protection system without pumper connection, having twenty (20) feet of head or less | D.C.V.A. Class 2 | A closed automatic fire protection system with pumper connection | D.C.V.A. Class 3 | A closed automatic fire protection system with pumper connection and an auxiliary water supply on or available to the premises; or an auxiliary water supply which may be located within one thousand seven hundred (1,700) feet of the pumper connection | R.P. Class 4 | A closed automatic fire protection system with a closed pressure tank supply (this class may have a jockey pump interconnected with the domestic water supply and/or an air compressor connection) | R.P. Class 5 | A closed automatic sprinkler system interconnected with an auxiliary water supply | R.P. Class 6 | Fire protection system used for the combined purposes of supplying the automatic sprinklers, hose lines, fire hydrants and stand pipes and being used for industrial purposes. (a) Self draining fire hydrants on premises presenting a health or system hazard (i.e., chemical plants, bulk storage yards, stock yard, sewer plants or similar facilities) where ground seepage of toxic materials may occur | R.P. (b) Self draining fire hydrants on premises presenting a non-health hazard (i.e., parks ballfields or similar facilities) where ground seepage of non-health hazard materials may occur. | D.C.V.A. (7) A backflow prevention assembly shall be required in all premises not described in the previous sections, with the exception of single-family dwellings. (8) Approval of a backflow prevention assembly shall be evidenced by a "certificate of approval" issued by an AWWA approved testing laboratory certifying full compliance with the AWWA and ASSE standards and F.C.C.C.H.R. specifications. Backflow prevention assemblies that have been fully tested and have been granted a Certificate of Approval may be installed without further testing or qualifications. (9) It shall be the duty of the owner at any premises where backflow prevention assemblies are installed to have certified inspections and operational tests performed at least once per year. Failed inspections, or those instances where the applicable water purveyor deems the hazard to be enough, shall require tests at six-month intervals. These inspections and tests shall be at no cost to the applicable water purveyor, and shall be performed only by a certified backflow technician, under the direction of a licensed plumbing contractor. Any replacement or repair of the backflow prevention assemblies shall require a permit issued by the city's building department. It shall be the duty of the applicable water purveyor to see that timely tests are made in accordance with section 312.9 of the most current edition of the Florida Building Code. These backflow prevention assemblies shall be repaired, overhauled or replaced at no cost to the applicable water purveyor whenever such devices are found to be defective. The certified backflow technician shall send two (2) certified records of such tests to the applicable water purveyor. (10) Nothing herein shall relieve the owner of the responsibility for conducting, or causing to be conducted, periodic surveys of water use practices on premises to determine where there are actual or potential cross connections in the customer system through which contaminants or pollutants could backflow into the water system. (11) All presently installed backflow prevention assemblies that do not meet the requirements of this ordinance shall be modified or replaced to satisfactorily protect the utility system. Whenever an existing backflow prevention assembly is moved from the present location, or the lack of maintenance constitutes a health hazard, the device must be recertified as correct for the new application in accordance with section 2245(4), (5), (6) and must be subsequently reinspected.
(Ord. No. 97-148, § 2, 1-6-98; Ord. No. 2009-111, § 2, 12-1-09; Ord. No. 2012-105, § 2, 5-15-12; Ord. No. 2023-101, § 111, 4-19-23)
Ask a question about Coral Springs law
Corpus searches the Coral Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.
