15-24-920 Safety clearances.

No dry cleaning building shall be located nearer than 100 feet to any building in which there is Group A, E, or I occupancy. At least one side of every dry cleaning building in which a flammable solvent having a flashpoint below 140 degrees Fahrenheit (closed cup tester) is used shall have a safety clearance of not less than 15 feet, and every side, which is nearer than 15 feet to another building or structure, or to a lot line, shall be a solid wall without any opening. (Prior code § 129.1-83; Amend Coun. J. 10-7-20, p. 21791, Art. VI, § 47)