§ 53-69. - Standards for filling tree cavities.
(a) All tree cavities shall be well drained so they will not catch water, will be open to air and avoid rotting and will not need filling. All cavities which need to be filled shall be filled with concrete or other approved compounds.
(b) All cavities filled in trees shall be traced out in an elliptical design and shall run parallel with the grain of the wood.
(c) When filling a tree cavity all decayed matter shall be removed and the cavity cleaned out up to and beyond the healthy wood. All cavities shall be disinfected with a standard wood disinfectant prior to installing filling. All large size cavities shall be lip bolted a maximum of 12 inches apart. All filling containing cement shall not contain more than three parts sand to one part cement. The concrete in all tree cavities when finished shall be in sections. All tree cavities shall first be reinforced with nails, wire, etc., as needed, to hold filling firm in the cavity. The filling in all tree cavities shall be installed with the outer edge of filling resting behind the cambium layer of the tree.
(d) All tree cavities shall have a drain tube located at the lower edge of the cavity.
(Code 1970, § 9-456; Code 1980, § 53-69)