§ 17.40.350 — Roof diaphragm stiffness
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 17.40.350
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/363ad9db-5266-449b-9832-d56d1e16f9a7
17.40.350 - Roof diaphragm stiffness.
A. General. The requirements of this section are in addition to the other analysis requirements of this part. The relative stiffness and strength of a diaphragm govern the amount of amplification of the seismic ground motion by the diaphragm, and therefore, a diaphragm stiffness and strength related check of the out-of-plane stability of unreinforced masonry walls anchored to wood diaphragms shall be made. This section contains a procedure for evaluation of the out-of-plane stability of unreinforced masonry walls anchored to wood diaphragms that are coupled to shear resisting elements. B. Definitions. The following definitions are applicable to this section: 1. Cross wall. A wood framed wall having a height-to-length ratio complying with Section 4713(d) or Table 25-I of the 1985 Uniform Building Code and sheathed with any of the materials described in Table No. 5 or Table No. 6. The total strength of all cross walls located within any forty feet length of diaphragm measured in the direction of the diaphragm span shall not be less than thirty percent of the strength of the diaphragm in the direction of consideration. 2. Demand capacity ratio (DCR) is a ratio of the following: a. Demand equals the lateral forces due to thirty-three percent of the combined weight of the diaphragm and the tributary weight of the walls and other elements anchored to the diaphragm. b. Capacity equals the diaphragm total shear strength in the direction under consideration as determined using the values in Table Nos. 5 or 6 of subsection B of this section. TABLE NO. 5 ALLOWABLE VALUES FOR EXISTING MATERIALS TO BE USED ONLY IN THE COMPUTATION OF THE DEMAND CAPACITY RATIO DESIGN CHECK Existing Materials or Configuration of Materials1 | Allowable Values 1. Horizontal diaphragms a. Roofs with straight sheathing and roofing applied directly to the sheathing. | 100 lbs. per foot for seismic shear. b. Roofs with diagonal sheathing and roofing applied directly to the sheathing. | 250 lbs. per foot for seismic shear. 2. Cross walls 2 | Per side; a. Plaster on wood or metal lath. | 200 lbs. per foot for seismic shear. b. Plaster on gypsum lath. | 175 lbs. per foot for seismic shear. c. Gypsum wall board unblocked edges. | 75 lbs. per foot for seismic shear. d. Gypsum wall board blocked edges. | 125 lbs. per foot for seismic shear 1 Materials must be sound and in good condition. 2 For cross walls, values of all materials may be combined, except the total combined value shall not exceed three hundred lbs. per foot for seismic shear. TABLE NO. 6 ALLOWABLE VALUES FOR NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION MATERIALS TO BE USED ONLY IN THE COMPUTATION OF THE DEMAND CAPACITY RATIO DESIGN CHECK New Materials or Configuration of New and Existing Materials1 | Allowable Values 1. Horizontal diaphragms a. Plywood sheathing applied directly over existing straight sheathing with ends of plywood sheets bearing on rafters and edges of plywood located on the center of individual sheathing boards. | 225 lbs. per foot for seismic shear. 2. Cross walls 2 a. Plywood sheathing applied directly over existing wood studs. No value shall be given to plywood applied over existing plaster or wood sheathing. | 1.33 times the values specified in Table 25-K of the 1985 UBC. b. Drywall or plaster applied directly over existing wood studs. | 100 percent of the values specified in Table 47-I of the 1985 UBC. 1 Materials must be sound and in good condition. 2 For cross walls, values of all materials may be combined, except the total combined shear value shall not exceed three hundred lbs. per foot for seismic shear. C. Notations. D = depth of diaphragm, in feet, measured perpendicular to the diaphragm span. h/t = height-to-thickness of an unreinforced masonry wall. The height shall be measured between wall anchorage levels and the thickness shall be measured through the wall cross section at the level under consideration. L = span of diaphragm between masonry shear walls or steel frames. Vc = total shear capacity of cross walls in the direction of analysis immediately below the diaphragm level being investigated as determined by using Table Nos. 5 or 6 of subsection B of this section. vu = maximum shear strength in pounds per foot for a diaphragm sheathed with any of the materials given in Table Nos. 5 or 6 of subsection B of this section. Wd = total dead load of the diaphragm plus the tributary weight of the walls anchored to the diaphragm, the tributary ceiling and partitions and weight of any other permanent building elements at the diaphragm level under consideration. D. Design Check Procedure. 1. General. The demand-capacity ratio (DCR) for the building shall be calculated using the following equations: DCR = 0.33 Wd / 2 vu D For building without cross walls; or DCR = 0.33 Wd / 2 vu V + Vc For building with cross walls. 2. Diaphragm Deflection. The calculated DCR shall be to the left of the curve in Figure No. A1. Where the calculated DCR is outside (to the right of) the curve, the diaphragm deflection limits are exceeded and cross walls may be used to reduce the deflection. 3. Unreinforced Masonry Wall Out-of-Plane Stability. The DCR shall be calculated discounting any cross wall. If the DCR from this method corresponding to the diaphragm span is to the right of the curve in Figure No. A1 of this subsection, the region within the curve at and below the intersection of the diaphragm span with the curve may be used to determine the allowable h/t values per Table No. 1 of Section 17.40.320 F.1.b. [image omitted; see the official code]
(Ord. 23766.)
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.