§ 14.04.335 — Section R309.2 of the 2025 Edition of the California Residential Code is amended to read as follows

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.335

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/36c7c45d-64e1-4792-a287-7213e69972be

14.04.335 - Section R309.2 of the 2025 Edition of the California Residential Code is amended to read as follows.

R309.2 One- and two-family dwellings automatic sprinkler systems. An automatic sprinkler system shall be installed in one- and two-family dwellings. All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system. Exceptions: 1. An automatic sprinkler system shall not be required for alterations to existing buildings that are not already provided with a sprinkler system. Whenever additions result in an additional level above or below grade, or a total increase of more than 1000 square feet (92.9 m 2) or more, or an increase of more than fifty percent (50%) of the existing floor area including mezzanines and additional stories, whichever is less, regardless of ownership. Additions shall be cumulative with each application for a building permit from January 1, 2008 to present day. R-3 occupancies shall not be required to comply with this section solely due to the addition of an additional level, unless the criteria for an increase of existing floor area is also exceeded or if the addition exceeds a combined total floor area of 3,600 square feet and fire flow requirements are not met. 2. Accessory Dwelling Unit, provided that all of the following are met: 2.1. The unit meets the definition of an Accessory Dwelling Unit as defined in the Government Code Section 65852.2. 2.2. The existing primary residence does not have automatic fire sprinklers. 2.3. The accessory detached dwelling unit does not exceed 1,200 square feet in size. 2.4. The unit is on the same lot as the primary residence. 2.5. All portions of exterior walls are within 150 feet from fire access road as measured by an approved route approved by the Fire Official. 2.6. All portions of exterior walls within 400 feet of a fire hydrant as measured by an approved route approved by the Fire Official. 3. Detached private garages, utility sheds, and similar structures 500 square feet or less, accessory to a R-3 occupancy, provided no portion of the structure is located more than 150 feet (45,720 mm) from an approved fire department access road. 4. Detached Carports, detached gazebos, pergolas, and similar shade structures open on all sides constructed of non-combustible material 500 square feet or less, accessory to a R-3 occupancy. 5. Other similar structures as deemed appropriate by the fire code official.

(Ord. No. 7461, § 5, 11-10-2025)