Sec. 5-121.246. - Technical amendments to the Florida Building Code, Residential.
1. Amend Chapter 3, Section R322 Flood-Resistant Construction, as follows: R322.2.2 Enclosed area below design flood elevation. Enclosed areas, including crawl spaces, that are below the design flood elevation shall: 1. Be used solely for parking of vehicles, building access or storage. The enclosed area shall not be conditioned space (temperature controlled) or finished or partitioned except for one storage area no larger than one hundred (100) square feet with one dimension not to exceed six (6) feet, access stairwells, ramps, and elevators, unless a partition is required by the fire code. The limitation on partitions does not apply to load bearing walls interior to perimeter wall (crawlspace) foundations. 1.1 Protection of building envelope. An exterior door that meets the requirements of R 609 shall be installed at the top of stairs that provide access to the building and that are enclosed with walls. 2. Be provided with flood openings that meet the following criteria and are installed in accordance with Section R322.2.2.1: 2.1 The total net area of non-engineered openings shall be not less than one (1) square inch (645 mm2) for each square foot (0.093 m2) of enclosed area where the enclosed area is measured on the exterior of the enclosure walls, or the openings shall be designed as engineered openings and the construction documents shall include a statement by a registered design professional that the design of the openings will provide for equalization of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwaters as specified in Section 2.7.2.2 of ASCE 24. 2.2 Openings shall be not less than three (3) inches (76 mm) in any direction in the plane of the wall. 2.3 The presence of louvers, blades, screens and faceplates or other covers and devices shall allow the automatic flow of floodwater into and out of the enclosed areas and shall be accounted for in the determination of the net open area. R322.2.3 Foundation design and construction. Foundations for buildings and structures erected in flood hazard areas shall meet the requirements of Chapter 4 and the construction documents shall include documentation that is prepared and sealed by a registered design professional that the foundation design accounts flood loads. R322.3.3 Foundations. Buildings and structures erected in coastal high-hazard areas and Coastal A Zones shall be supported on pilings or columns and shall be adequately anchored to such pilings or columns. The space below the elevated building shall be either free of obstruction or, if enclosed with walls, the walls shall meet the requirements of Section R3223.5. Pilings shall have adequate soil penetrations to resist the combined wave and wind loads (lateral and uplift). Water-loading values used shall be those associated with the design flood. Wind-loading values shall be those required by this code. Pile embedment shall include consideration of decreased resistance capacity caused by scour of soil strata surrounding the piling. Pile systems design and installation shall be certified in accordance with Section R322.3.9. Spread footing, mat, raft or other foundations that support columns shall not be permitted where soil investigations that are required in accordance with Section R401.4 indicate that soil material under the spread footing, mat, raft or other foundation is subject to scour or erosion from wave-velocity flow conditions. If permitted, spread footing, mat, raft or other foundations that support columns shall be designed in accordance with ASCE 24. Slabs, pools, pool decks and walkways shall be located and constructed to be structurally independent of buildings and structures and their foundations to prevent transfer of flood loads to the buildings and structures during conditions of flooding, scour or erosion from wave-velocity flow conditions, unless the buildings and structures and their foundations are designed to resist the additional flood load. R322.3.4 Concrete slabs. Concrete slabs used for parking, floors of enclosures, landings, decks, walkways, patios and similar uses that are located beneath structures, or slabs that are located such that if undermined or displaced during base flood conditions could cause structural damage to the building foundation, shall be designed and constructed in accordance with one of the following: 1. To be structurally independent of the foundation system of the structure, to not transfer flood loads to the main structure, and to be frangible and break away under flood conditions prior to base flood conditions. Slabs shall be a maximum of four (4) inches (102 mm) in thickness, shall not have turned-down edges, shall not contain reinforcing, shall have isolation joints at pilings and columns, and shall have control or construction joints in both directions spaced not more than four (4) feet (1219 mm) apart. 2. To be self-supporting, structural slabs capable of remaining intact and functional under base flood conditions, including erosion and local scour, and the main structure shall be capable of resisting any added flood loads and effects of local scour caused by the presence of the slabs. R322.3.5 Walls below design flood elevation. Walls and partitions are permitted below the elevated floor, provided that such walls and partitions are not part of the structural support of the building or structure and: 1. Electrical, mechanical and plumbing system components are not to be mounted on or penetrate through walls that are designed to break away under flood loads; and 2. Are constructed with insect screening or open lattice; or 3. Are designed to break away or collapse without causing collapse, displacement or other structural damage to the elevated portion of the building or supporting foundation system. Such walls, framing and connections shall have a resistance of not less than ten (10) (479 Pa) and not more than twenty (20) pounds per square foot (958 Pa) as determined using allowable stress design; or 4. Where wind loading values of this code exceed twenty (20) pounds per square foot (958 Pa), as determined using allowable stress design, the construction documents shall include documentation prepared and sealed by a registered design professional that: 4.1. The walls and partitions below the design flood elevation have been designed to collapse from a water load less than that which would occur during the base flood. 4.2. The elevated portion of the building and supporting foundation system have been designed to withstand the effects of wind and flood loads acting simultaneously on structural and nonstructural building components. Waterloading values used shall be those associated with the design flood. Wind-loading values shall be those required by this code. 5. Walls intended to break away under flood loads as specified in Item 3 or 4 have flood openings that meet the criteria in Section R322.2.2, Item 2. R322.3.6 Enclosed areas below the design flood elevation. Enclosed areas below the design flood elevation shall be used solely for parking of vehicles, building access or storage. The enclosed area shall not be conditioned space (temperature controlled) or finished or partitioned except for one storage area no larger than one hundred (100) square feet with one dimension not to exceed six (6) feet, access stairwells, ramps, and elevators, unless a partition is required by the fire code. R322.3.6.1 Protection of building envelope. An exterior door that meets the requirements of Section R609 shall be installed at the top of stairs that provide access to the building and that are enclosed with walls designed to break away in accordance with Section R322.3.4. R322.3.7 Stairways and ramps. Stairways and ramps that are located below the lowest floor elevations specified in Section R322.3.2 shall comply with one or more of the following: 1. Be designed and constructed with open or partially open risers and guards. 2. Stairways and ramps not part of the required means of egress shall be designed and constructed to break away during design flood conditions without causing damage to the building or structure, including the foundation. 3. Be retractable, or able to be raised to or above the lowest floor elevation, provided that the ability to be retracted or raised prior to the onset of flooding is not contrary to the means of egress requirements of the code. 4. Be designed and constructed to resist flood loads and minimize transfer of flood loads to the building or structure, including the foundation. Areas below stairways and ramps shall not be enclosed with walls below the design flood elevation unless such walls are constructed in accordance with Section R322.3.5
(Ord. No. 2024-15, § 2(Exh. A), 2-1-2024)
Ask a question about Tampa law
Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.