§ 14-552 — Specific standards
Code of Ordinances, City of Corpus Christi, Texas (Supp. No. 44: codified through Ordinance No. 033940, enacted June 2, 2026) · Corpus Christi Code of Ordinances § 14-552
Corpus is an independent public-information project, not the official City of Corpus Christi website. Stable reference: corpuslaw.us/code/3703a7e5-5724-4a76-a95f-6d0aa920bc5d
Sec. 14-552. - Specific standards.
In all areas of special flood hazards where base flood elevation data has been provided as set forth in section 14-521, subsection 14-542(8), or subsection 14-543(c), the following provisions are required: (1) Residential construction. New construction of any residential structure must have the lowest floor (including basement) and machinery or equipment, elevated to one (1) foot above the base flood elevation. Substantial damage and substantial improvement must have the lowest floor (including basement) and machinery or equipment, elevated to one (1) foot above the base flood elevation. Attached garages and enclosures below elevated buildings must meet the minimum NFIP requirements (elevated to the base flood elevation or have proper openings). A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in subsection 14-533(b)(1), is satisfied. (2) Nonresidential construction. New construction of any commercial, industrial, or other nonresidential structure must either have the lowest floor (including basement) elevated to one (1) foot above the base flood level or together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Substantial damage and substantial improvement must have the lowest floor (including basement), elevated to at or above the base flood elevation or together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are flood-proofed shall be maintained by the floodplain administrator. (3) Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding must be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding must be provided. b. The bottom of all openings must be no higher than one (1) foot above grade. c. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes. a. All manufactured homes to be placed within zone A on a city's FHBM or FIRM must be installed using methods and practices which minimize flood damage. 1. For the purposes of this requirement, a manufactured home must be elevated and anchored to resist flotation, collapse or lateral movement. 2. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. 3. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. Manufactured homes that are placed or substantially improved within zones A1-30, AH, and AE on the city's FIRM must be on sites: 1. Outside of a manufactured home park or subdivision. 2. In a new manufactured home park or subdivision. 3. In an expansion to an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as a result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to one (1) foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. c. Manufactured homes must be placed on substantially improved on sites in an existing manufactured home park or subdivision with zones A1-30, AH, and AE on the city's FIRM that are not subject to the provisions of subsection (4) of this section must be elevated and the more stringent of the two (2) is required: 1. The lowest floor of the manufactured home is one (1) foot above the base flood elevation, 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. (5) Recreational vehicles. Recreational vehicles placed on sites within zones A1-30, AH, and AE on the city's FIRM either: a. Must be on the site for fewer than one hundred eighty (180) consecutive days, b. Must be fully licensed and ready for highway use, or c. Must meet the permit requirements of subsection 14-545(a), and the elevation and anchoring requirements for manufactured homes in subsection (4) of this section. (6) A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices, and has no permanently attached additions.
(Ord. No. 25467, § 1, 9-9-2003; Ord. No. 031740, § 1, 4-16-2019; Ord. No. 032888, § 1, 10-11-2022; Ord. No. 033326, § 1, 3-26-2024)
Ask a question about Corpus Christi law
Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.
