R802 — WOOD ROOF FRAMING

The Philadelphia Code (2026 Code: The Philadelphia Code and Home Rule Charter current through October 8, 2026) · Philadelphia Code Subcode R, § R802

Corpus is an independent public-information project, not the official City of Philadelphia website. Stable reference: corpuslaw.us/code/37370903-09a1-4484-9bf1-ce137afb1bbb

SECTION R802 WOOD ROOF FRAMING

[Pursuant to the UCC, delete Section R802.3 and replace as follows:] R-R802.3 Ridge. A ridge board used to connect opposing rafters shall be not less than 1 inch (25 mm) nominal thickness and not less in depth than the cut end of the rafter. Where ceiling joist or rafter ties do not provide continuous ties across the structure as required by Section R802.5.2, the ridge shall be supported by a wall or ridge beam designed in accordance with accepted engineering practice and supported on each end by a wall, or column, or girder. * * *