§ 25-27 — Appliances in Sleeping Rooms
New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · 28 RCNY § 25-27
Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/378feb0d-a6ae-4825-994d-dbcc39723f03
§ 25-27 Appliances in Sleeping Rooms.
(a) Gas-fueled water heaters shall not be installed in a room occupied for sleeping purposes, in bathrooms, or in any occupied room normally kept closed. (b) It shall be unlawful to install a gas-fueled space heater in a room occupied for sleeping purposes except when the space heater is so designed, installed and operated for it: (1) Obtains combustion air directly from the outside of the building or through a duct leading to the outside. (2) It vents directly to space outside of the building other than an inner court, or is connected through a flue or outlet pipe with an outside chimney which conforms with the requirements of subarticle three of article twelve of the Building Code. A flue in an existing brick chimney may be used if it is in good condition and tests show that it will provide adequate draft.