Sec. F. - Coastal high hazard areas.
(1) Located within areas of special flood hazard areas established in article 3, section B (maps) are coastal high hazard areas, designated as VE Zones. These areas have special flood hazards associated with high velocity waters from wave action due to hurricanes, tsunamis, or other seismic sources. The following provisions, in addition to the standards of article 5, sections A, B, C, and D, except for B(7), shall also apply: (2) All new construction and substantial improvements in VE Zones shall be elevated on pilings or columns so that: a.) The bottom of the lowest horizontal structural member of the lowest floor, excluding the pilings or columns, is elevated a minimum of one (1) foot or one (1) foot above the centerline of the street, whichever is greater, and; b.) The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those requirements by state or local building codes. (3) A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of article 5, section F(1). (4) Obtain the elevation, in relation to mean sea level, of the bottom of the lowest structural member of the lowest floor, excluding pilings and columns, of all new and substantially improved structures in VE Zones. The floodplain administrator shall maintain a record of all such information. (5) All new construction shall be located landward of the reach of mean high tide. (6) All new construction and substantial improvements in VE Zones shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood latticework, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purpose of this section, a breakaway wall shall have a design safe loading resistance of not less than ten (10) and no more than twenty (20) pounds per square foot. Use of breakaway walls which exceed a design safe loading resistance of twenty (20) pounds per square foot, either by design or when so required by local codes, may be permitted only if a registered professional engineer or architect certifies that the designs proposed meet the following conditions: a.) Breakaway wall collapse shall result from water load less than that which would occur during the base flood, and; b.) The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components, structural and nonstructural. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those requirements by state or local building codes. The lowest horizontal structural member should be oriented perpendicular to the expected wave crest. (7) If breakaway walls are utilized, such enclosed space shall be useable solely for storage, parking of vehicles, or building access. Such space shall not be used for human habitation and finished or portioned into separate rooms. (8) Enclosures below elevated buildings shall be useable solely for storage, parking of vehicles, or building access. Such space will not be used for human habitation and not finished or partitioned into separate rooms. (9) Prohibit the use of fill for structural support of buildings. Under the buildings or structures, no fill may be used except for minor site grading for drainage purposes. Nonstructural fill may be used on coastal building sites for minor landscaping and site grading for drainage purposes as long as the fill does not interfere with the free passage of floodwaters and debris underneath the building or cause changes in flow direction during coastal storms such that will cause additional damage to buildings on the site or to any adjacent buildings. Certification by a professional engineer or architect shall be submitted along with design calculations demonstrating that no adverse impacts will result. (10) Prohibit man-made alteration of sand dunes that would increase potential flood damage. (11) All manufactured homes to be placed or substantially improved within VE Zones on the Community's FIRM on site: a.) Outside of a manufactured home park or subdivision, b.) In a new manufactured home park or subdivision, c.) In an expansion to an existing manufactured home park or subdivision, or d.) In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood; e.) Shall meet the standards of this article 5, section F and that manufactured homes placed or substantially improved on other sites in an existing manufactured home park or subdivision with VE Zones on the FIRM meet the requirements of article 5, section B(6). (12) All new structures shall be located on the lot so as to minimize exposure to coastal hazards and shoreline erosion, Structures shall be located outside the coastal high hazard area, to the greatest extent possible. (13) Recreational vehicles and/or temporary structures placed on sites within VE Zones on the Community's FIRM shall either: a.) Be permitted before being placed on site and be on site for fewer than one hundred eighty (180) consecutive days and shall leave the site and obtain a new permit before returning to the same site, and; b.) Be fully licensed and ready for highway use, on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions, or; c.) Meet the requirements of article 5, section F(1) through (10) and (12).
(Ord. No. 2929, Art. 5, § F, 12-19-17; Ord. No. 3005, § 2D, 7-2-19)
Ask a question about Gulfport law
Corpus searches the Gulfport sections it holds and shows the ones that match, with their citations. Free, no sign-in.