§ 1109 — Emergency escapes, egress, and smoke detectors

Tulsa Revised Ordinances (Supp. No. 3, Update 2: codified through Ordinance No. 25794, passed May 13, 2026) · Tulsa Revised Ordinances tit. 55, § 1109

Corpus is an independent public-information project, not the official City of Tulsa website. Stable reference: corpuslaw.us/code/392cab18-8f96-4732-a242-efe0f3043da2

Section 1109. - Emergency escapes, egress, and smoke detectors.

1109.1 Openable window or door unit required. Any room used for sleeping within a residential rental dwelling unit must have at least one (1) openable window or door unit for emergency escape or rescue in accordance with building or housing codes. The units shall be operable from the inside and provide a clear, unobstructed opening without the use of separate tools. 1109.2 Egress components maintenance. All egress components, including but not limited to interior and exterior walkways, landings, stairways, balconies, and sidewalks shall be maintained in a structurally-sound condition, free from any tripping hazard. 1109.3 Fire Safety Systems and Extinguishers. 1109.3.1 Fire safety system maintenance. Fire safety systems in the form of fire suppression and alarm systems shall be installed and maintained in good operating condition in accordance with the building or housing code edition in effect when the residential rental dwelling was constructed or altered. Fire suppression and alarm systems shall be inspected and tested annually in accordance with the provisions of the Fire Extinguisher Licensing Act, 59 O.S., Sections 1800.1 et seq., Alarm and Locksmith Industry Rules, OAC 380:75, and properly display a current inspection tag. 1109.3.2 Smoke alarms requirements. If fire suppression and alarm systems are not required for a building, a smoke alarm is required for each residential rental dwelling unit. Smoke alarms may be battery-operated or may receive their power from the building wiring and shall be mounted in accordance with manufacturer's instructions on the ceiling or wall at a point centrally located in the corridor or area giving access to each sleeping area. Smoke alarms shall sound an alarm audible in all sleeping areas of the dwelling unit in which they are located. 1109.3.3 Fire extinguisher installation and maintenance. Fire extinguishers shall be installed, maintained, and readily accessible to residents, tenants, occupants, and invitees in accordance with the current building and housing codes. Fire extinguishers must be inspected annually in accordance with Fire Extinguisher Licensing Act, 59 O.S., Sections 1820.1 et seq., Fire Extinguisher Industry Rules, OAC 265:50-5-1, and properly display a current inspection tag.

(Ord. No. 25115, § 1, 8-30-2023)

Ask a question about Tulsa law

Corpus searches the Tulsa sections it holds and shows the ones that match, with their citations. Free, no sign-in.