Sec. 49-1601. - Energy conservation.
(a) Commercial installations. (1) All water heating equipment not supplied with integral heat traps and serving non-circulating systems shall be provided with heat traps on the supply and discharge piping. Heat traps are not to be installed on water heaters with recirculation piping. (2) Insulate the first eight feet in non-circulating of the inlet and outlet piping including the heat trap with one-half inch of insulation having a conductivity of exceeding 0.27 Btu per inch/h × ft 2 × °F. (3) For automatic-circulating hot water systems, piping shall be insulated with one inch of insulation having a conductivity not exceeding 0.27 Btu per inch/h × ft 2 × °F. (4) The closer the heat trap is to the tank, the more efficiently it will trap heat in the tank. (5) Any loop shall be made of Type L copper from a manufacture approved by the plumbing board. (b) Residential installations. (1) All circulating hot water piping shall be insulated to a least R-2. (2) Shall include an automatic or readily accessible manual switch that can turn off the circulating pump when the system is not in use.
(Ord. No. 40524, § 1, 10-20-15)