For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.68.310 — Standard form HMMP

San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 17.68.310

Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/39b9c8ff-f1e3-41cc-bfe0-e343915fe26c

17.68.310 - Standard form HMMP.

The standard form hazardous materials management plan must be submitted unless the facility qualifies as a minimal storage site under Section 17.68.320 below. The HMMP shall include the following: A. Facility Description. 1. General information. The HMMP shall contain the name and address of the facility and business phone number of applicant, the name and titles and emergency phone numbers of the primary response person and an alternate, the number of employees, number of shifts, hours of operation, and principal business activity. 2. General facility description. The HMMP shall contain a map drawn at a legible scale and in a format and detail determined by city. It shall show the location of all buildings and structures, chemical loading areas, parking lots, internal roads, storm and sewer drains, and shall specify the uses of adjacent properties. The city may also require information as to the location of wells, floodplains, earthquake faults, surface water bodies, and/or general land uses (schools, hospitals, institutions, residential areas) within one mile of the facility boundaries. 3. Facility storage map. a. The HMMP shall contain a facility storage map at a legible scale for licensing and enforcement purposes. The information in this section is provided for purposes of ensuring the suitable and secure storage of hazardous materials and for the protection and safety of emergency response personnel of city. City shall take reasonable precautions to ensure the confidentiality of the information provided pursuant to this subsection. The facilities storage map shall indicate the location of each hazardous materials storage facility, including all interior, exterior, and underground storage systems, and access to such storage systems. In addition, the map shall indicate the location of emergency equipment related to each storage facility, and the general purpose of the other areas within each facility. For each storage facility, the map shall contain information as prescribed below; except that where the hazardous material being stored is a trade secret, it shall be identified in a coded manner (together with its key) and not in a manner which would reveal trade secret information: (i) A floor plan to scale and the permit quantity limit; (ii) For each nonwaste hazardous material which is stored in a quantity greater than the quantities specified in Section 17.68.360A, the general chemical name, common/trade name, major constituents for mixtures, United Nations (UN) or North America (NA) number, if available, and physical state. For each waste hazardous material stored in any quantity within the storage facility, the presence of wastes shall also be indicated; (iii) For all hazardous materials, including wastes, stored in each storage facility, the hazard class or classes and the quantity range for each such class, aggregated within each storage facility, in the following ranges: Quantity Range Number | Range Amounts 1 | Less than 500 pounds of solids, less than 55 gallons for liquids, and less than 200 cubic feet at STP for compressed gases; 2 | Between 500 and 4,999 pounds for solids, between 55 and 549 gallons for liquids, and between 200 and 1,999 cubic feet at STP for compressed gases; 3 | Between 5,000 and 24,999 pounds for solids, between 550 to 2,749 gallons for liquids, and between 2,000 and 9,999 cubic feet at STP for compressed gases; 4 | Between 25,000 and 49,999 pounds for solids, between 2,750 and 5,499 gallons for liquids, and between 10,000 and 19,999 cubic feet at STP for compressed gases; 5 | 50,000 pounds or more for solids, 5,500 gallons or more for solids, 5,500 gallons or more for liquids, and 20,000 cubic feet or more at STP for compressed gases; (iv) For materials not regulated under this chapter, but regulated under the Uniform Fire Code, such as radioactives or cryogens, or for materials stored in storage facilities exempted by Sections 17.68.1130A and 17.68.1130B, the city may require that the hazard class or classes and the quantity range of each such hazard class, using the quantity ranges listed in subsection (iii) above, be provided; (v) For tanks, the capacity limit of each tank, and the hazardous material contained in each tank by general chemical name, common/trade name, major constituents for mixtures, United Nations (UN) or North America (NA) number, if available, and physical state. b. Due to the threat to the security of the facility posed by the disclosure of the information in the facility storage map, this information shall be maintained by city for law enforcement purposes only and shall not be made public. Public disclosure of this information could endanger the security of the facility or present a clear danger to public health and safety. City shall not disclose this information to the public without the consent of the permittee or permit applicant unless ordered to do so by a court of competent jurisdiction. Permittee or permit applicant shall be deemed a real party in interest in any such action. Prompt notice of a lawsuit to compel disclosure shall be given by city to permittee or permit applicant. However, city shall be under no duty to prevent disclosures where there has been any unauthorized discharge of hazardous materials stored in storage facility(ies) shown on such map or where such disclosure arises out of any official emergency response relating to the storage facility(ies). c. The facility storage map shall be updated annually or whenever an additional approval is required for the facility or whenever the hazardous materials inventory statement is required to be amended pursuant to Section 17.68.350. B. Hazardous Materials Inventory Statement. A hazardous materials inventory statement shall be filed in accordance with Part 5 of this chapter. C. Separation of Materials. The HMMP shall contain a description of the methods to be utilized to ensure separation and protection of stored hazardous materials from factors which may cause a fire or explosion, or the production of a flammable, toxic, or poisonous gas, or the deterioration of the primary or secondary containment. D. Monitoring Program. The HMMP shall contain a description of the location, type, manufacturer specifications (if applicable), and suitability of monitoring methods to be used in each storage facility storing hazardous materials which are liquids or solids at STP. It shall also specify the frequency of inspections of storage facilities which will be conducted by the permittee. E. Recordkeeping Forms. The HMMP shall contain an inspection check sheet or log designed to be used in conjunction with routine inspections. The check sheet or log shall provide for the recording of the date and time of inspection and, for monitoring activity, the date and time of any corrective action taken, the name of the inspector, and the countersignature of the designated safety manager for the facility or the responsible official as designated in the HMMP. F. Emergency Equipment. The HMMP shall describe emergency equipment availability, testing, and maintenance. G. Variation in Information. 1. Additional information may be required for the HMMP where such information is reasonably necessary to meet the intent of this chapter. 2. Whenever permittee has submitted a plan which includes substantially the same information as is required for any component(s) of the HMMP to any other public agency regulating hazardous materials, such plan may be submitted to city in lieu of such component(s). The city may give deference to any approval of such plan by the other public agency.

(Ords. 21334, 22379, 22555.)

Ask a question about San Jose law

Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.