295-505. Design Standards.
1. INTRODUCTION. The purposes of the design standards of this section are to:
a. Maintain Compatibility with Neighborhood Context. An objective of these design standards is to ensure that buildings in residential districts fit within the context in which they are built. Lot sizes, lot coverages, height and other design parameters vary by district to ensure that the requirements of this section closely match the existing built environment.
b. Allow Flexibility in Development. Flexibility in meeting design standards is achieved by providing ranges, exceptions and alternatives which are consistent with the spirit and intent of this chapter. These ranges, exceptions and alternatives allow various site-specific and project-specific issues to be addressed while still taking into account the intention of the zoning district.
c. Consistency with the Principles of Urban Design. These design standards strive to promote development that is consistent with the “Principles of Urban Design” adopted by the city plan commission as part of the city’s comprehensive plan and maintained on file in the office of the commission and in the legislative reference bureau. Residential development and alterations should not only be compatible with the character of the neighborhood, but also create pedestrian-friendly environments, allow varying degrees of land use diversity within each zoning district, and promote environments which support transportation diversity consistent with neighborhood context.
d. Promote Usage of Sustainable Building Materials that Add Long-Term Value to Neighborhoods. Façades should be constructed of durable materials that resist denting, splitting, cracking, fading, peeling and other damage. Façade components should be finished-quality materials appropriate for street-facing character, with finished and refined edges, rather than utility-grade materials that are rough and disorderly. Façades should consist of context-appropriate materials that fit the character of urban locations throughout the city.
2. PRINCIPAL BUILDING STANDARDS. a. Introduction. Principal building standards are established to ensure that new construction of principal buildings in residential districts, as well as additions and alterations to existing buildings, is appropriate for the surrounding context in terms of size, placement, height and design characteristics. The design standards for principal buildings are set forth in table 295-505-2. These standards apply to non-residential buildings as well as residential buildings. The provisions of this subsection explain, qualify or specify exceptions to the standards in the table.
b. Front Setback Standards. b-1. Intent. Front setback standards are intended to ensure that the front façade or elements of new construction or additions maintain relationships to the front lot line that are similar to the corresponding relationships for buildings of similar use in the immediate vicinity. At least 30% of the front façade of a principal building, measured in terms of lineal feet of building frontage, shall meet the standards of this paragraph. The remaining 70% or less of the front façade may be set back farther from the street than the required setback, but not closer to it.
b-2. Setback Average and Range. When table 295-505-2 specifies that the minimum front setback for a principal building in a residential district shall be determined by averaging, the front setback may be anywhere in the range of the average setback minus 20% to the average setback plus 20%.
b-3. Determination of “Front.”
b-3-a. Interior Lot. The street frontage shall be the “front.”
b-3-b. Corner Lot. The “front” of a corner lot shall be along the same street as the immediately adjacent interior lot. When a corner lot is immediately adjacent to 2 or more interior lots, the street lot line with the smallest dimension shall be the “front.” An interior lot separated by an alley or other public way not exceeding 20 feet in width from the corner lot being developed shall be considered to be immediately adjacent to that corner lot.
b-3-c. Through Lot. When a lot has only 2 street frontages and those frontages are on opposite sides of the lot, the “front” of the lot shall be along the same street as the fronts of the immediately adjacent interior lots. When the fronts of the immediately adjacent lots are on different streets, the permit applicant shall specify which street frontage is the “front.”
b-3-d. Lot with More than 2 Frontages. When a lot is bounded by more than 2 streets, the permit applicant shall specify which street frontage is the “front.”
b-4. Required Setback For New Construction. When table 295-505-2 requires use of an average to determine front setback, the average shall be determined using the most applicable of the following methods:
b-4-a. Adjacent Structures. Where immediately adjacent lots contain principal buildings, the front setback dimensions of those structures shall be averaged to establish the average front setback.
b-4-b. No Adjacent Structures. If one or both adjacent lots do not contain principal buildings, the average front setback shall be determined by averaging the front setbacks of the 2 nearest principal buildings located on the same blockface, on adjacent blockfaces on the same side of the street, on the blockface across the street or on the nearest similar street, in that order.
Table 295-505-2 PRINCIPAL BUILDING DESIGN STANDARDS
Single-family Districts | Two-family Districts
RS1 | RS2 | RS3 | RS4 | RS5 | RS6 | RT1 | RT2 | RT3 | RT4 | RT5
Lot | Lot area, minimum (sq. ft.)
20,000 | 12,000 | 9,000 | 7,200 | 6,000 | 3,600 | 7,200 | 4,800 | 3,000 | 2,400 | 2,400
detached housing
not applicable | 3,600 | 3,000 | 1,800 | 1,800 | 1,800
Lot area, minimum (sq. ft.)
attached housing
Lot area, maximum (sq. ft.) | none | none | none | none | none | none | none | none | none | none | none
Lot width, minimum (ft.) | 100 | 100 | 75 | 60 | 50 | 30 | 60 | 40 | 30 | 24 | 24
detached housing
Lot width, minimum (ft.) | not applicable | 30 | 25 | 18 | 18 | 16
attached housing
Lot width, maximum (ft.) | none | none | none | none | none | none | none | none | none | none | 80
Density | Lot area per dwelling unit, | none | none | none | none | none | 3,600 | 3,600 | 2,400 | 1,800 | 1,200 | 800
minimum (sq. ft.) ***
Lot area per roomer or transitional | NA | NA | NA | NA | NA | NA | NA | NA | NA | 600 | 600
housing client, minimum (sq. ft.)
Lot coverage, minimum interior lot | none | none | none | none | none | * | none | none | * | * | *
Lot coverage, maximum interior lot | 15% | 30% | 30% | 30% | 30% | 60% | 30% | 30% | 50% | 70% | 70%
Lot coverage, minimum corner lot | none | none | none | none | none | * | none | none | * | * | *
Lot coverage, maximum corner lot | 15% | 30% | 30% | 30% | 40% | 70% | 40% | 40% | 60% | 85% | 85%
Floor area, minimum | 1,500 | 1,500 | 1,300 | 1,200 | 900 | none | none | none | none | none | none
(sq. ft.) one-story structure
Floor area, minimum | 1,900 | 1,900 | 1,700 | 1,450 | 1,200 | none | none | none | none | none | none
(sq. ft.) split-level or taller
Height | Height, minimum (ft.) | none | none | none | none | none | ** | none | none | * | * | *
Height, maximum (ft.) | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 48 | 48
*The requirements of table 295-505-2-i apply in lieu of the minimum lot coverage and minimum height requirements of this table.
**A structure shall meet the minimum height requirements of table 295-505-2-i unless it is adjacent to a lot containing a one-story house,
in which case there shall be no minimum height requirement.
*** Accessory dwelling units shall not be included in lot area per dwelling unit calculations.
Table 295-505-2 PRINCIPAL BUILDING DESIGN STANDARDS
Single -family Districts
Two-family Districts
RS1 | RS2 | RS3 | RS4 | RS5 | RS6 | RT1 | RT2 | RT3 | RT4 | RT5
Frontage Primary | average or | average or
Front setback, minimum (ft.) | 25 ft., | 25 ft.,
average | average | average | average | average | average | average | average | average
(see s. 295-505-2-b) | whichever is | whichever is
less | less
Front setback, maximum (ft.) | none | none | none | none | average | average | none | none | average but never more than 20 ft.
(see s. 295-505-2-b)
20% of lot width but never more than 20 ft. | 10% of lot width but never more than 15 ft. | 10% of lot width but never more than 6 ft. | 20% of lot width but never more than 20 ft. | 10% of lot width but never more than 6 ft. | 3 | 3
Side street setback, minimum (ft.)
Side street setback, maximum (ft.) | none | none | none | none | none | none | none | none | none | 15 | 15
Setback Side | North or west side setback, minimum (ft.) | 3 | 3 | 3 | 3 | 3 | 1.5 | 3 | 3 | 1.5 | 1.5 | 3
South or east side setback, minimum (ft.) | 6 | 6 | 6 | 6 | 6 | 3 | 6 | 6 | 3 | 3 | 3
Combined side setback, minimum (ft.) | 12 | 12 | 12 | 12 | 12 | 4.5 | 12 | 12 | 4.5 | 4.5 | 6
Maximum depth of building | 50 | 50 | 50 | 50 | 50 | 75 | 50 | 50 | 75 | 100 | 100
without side setback adjustment
Max. no. of stories without | 2 | 2 | 2 | 3 | 3 | 3 | 2 | 2 | 3 | 4 | 4
side or rear setback adjustment
Setback Rear | Rear setback, minimum (ft.) interior lot | 25 | 25 | 25 | 20 | 15 | 15 | 25 | 25 | 15 | 15 | 15
Rear setback, minimum (ft.) corner lot | 25 | 25 | 25 | 15 | 10 | 10 | 20 | 20 | 10 | 10 | 10
Rear street setback, minimum (ft.) | average | average | average | average | average | average | average | average | average | average | average
(see s. 295-505-2-e)
Rear street setback, maximum (ft.) | none | none | none | none | none | none | none | none | none | none | none
no | no | no | no | no | same as RT4 | no | no | no | yes, if in existence on Nov. 22, 2003; otherwise, special use | yes
Multiple principal residential buildings permitted?
***
*** In addition to the principal residential building, one detached accessory dwelling unit is permitted on a parcel in any RS or RT district.
Table 295-505-2 PRINCIPAL BUILDING DESIGN STANDARDS
Multi-family Districts | Residence & Office
RM1 | RM2 | RM3 | RM4 | RM5 | RM6 | RM7 | R01 | R02
Lot | Lot area, minimum (sq. ft.) | 3,600 | 3,600 | 3,000 | 2,400 | 2,400 | 2,400 | 2,400 | 3,600 | 2,400
detached housing
Lot area, minimum (sq. ft.) | 3,000 | 3,000 | 1,800 | 1,800 | 1,800 | 1,800 | 1,800 | 3,000 | 1,800
attached housing
Lot area, maximum (sq. ft.) | none | none | none | none | none | none | none | none | none
Lot width, minimum (ft.) | 40 | 40 | 30 | 24 | 24 | 24 | 24 | 30 | 24
detached housing
Lot width, minimum (ft.) | 25 | 25 | 18 | 18 | 18 | 18 | 18 | 25 | 18
attached housing
Lot width, maximum (ft.) | none | none | none | none | none | none | none | none | none
Density | Lot area per dwelling unit, minimum (sq. ft.) | 2,400 | 1,200 | 2,400 ea. (3 or more); 3,600 for 2; 1,800 for 1 | 1,200 | 800 | 400 | 150 | 2,400 | 400
***
Lot area per dwelling unit, | 1,200; 2,400 for a unit with 2 or more bedrooms | 600; 1,200 for a unit with 2 or more bedrooms | 900; 1,800 for a unit with 2 or more bedrooms | 600; 1,200 for a unit with 2 or more bedrooms | 400; 800 for a unit with 2 or more bedrooms | 200; 400 for a unit with 2 or more bedrooms | 75; 150 for a unit with 2 or more bedrooms | 1,200; 2,400 for a unit with 2 or more bedrooms | 200; 400 for a unit with 2 or more bedrooms
permanent supportive housing,
minimum (sq. ft.)**
Lot area per roomer or transitional housing client, | 1,200 | 600 | 900 | 600 | 400 | 200 | 75 | 1,200 | 200
minimum (sq. ft.)**
Lot coverage, minimum interior lot | 15% | 15% | * | * | * | * | 20% | 15% | *
Lot coverage, maximum interior lot | 30% | 50% | 50% | 70% | 70% | 70% | 85% | 30% | none
Lot coverage, minimum corner lot | 15% | 15% | * | * | * | * | 20% | 15% | *
Lot coverage, maximum corner lot | 40% | 60% | 60% | 85% | 85% | 85% | 85% | 40% | none
Floor area, minimum (sq. ft.) | none | none | none | none | none | none | none | none | none
One-story structure
Floor area, minimum (sq. ft.) | none | none | none | none | none | none | none | none | none
Split level or taller
*The requirements of table 295-505-2-i apply in lieu of the minimum lot coverage and minimum height requirements of this table. ** For premises with a mixture of residential types including either permanent supportive housing or transitional housing, the minimum lot area per dwelling unit or per roomer or transitional housing client shall be calculated pursuant to s. 295-505-2-n. *** Accessory dwelling units shall not be included in lot area per dwelling unit calculations.
Table 295-505-2 PRINCIPAL BUILDING DESIGN STANDARDS
Multi-family Districts | Residence & Office
RM1 | RM2 | RM3 | RM4 | RM5 | RM6 | RM7 | R01 | R02
HEIGHT | Height, minimum (ft.) | none | none | * | * | * | * | 20 | none | *
Height, maximum (ft.) | 45 | 45 | 45 | 60 | 60 | 85 | 85; no limit if | 45 | 85
floor area ratio is
less than 4:1
Frontage Primary | Front setback, minimum (ft.) | average | average | average | average | average | average | average | average | average
(see s. 295-505-2-b)
Front setback maximum (ft.) | none | none | average but not more than 20 ft. | average but never more than 15 ft. | none | 15 ft.
(see s. 295-505-2-b)
Side street setback, minimum (ft.) | 10% of lot width but not more than 15 ft. | 3 | 3 | 3 | 3 | 3 | same as RM1-RM2 | none
none | none | 15 | 15 | 15 | 15 | 15 | none | none
Side street setback, maximum (ft.)
Setback Side | 3 | 3 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 3 | none
North or west side setback, minimum (ft.)
6 | 6 | 3 | 3 | 3 | 3 | 3 | 6 | none
South or east side setback, minimum (ft.)
12 | 12 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 12 | none
Combined side setback, minimum (ft.)
Maximum depth of building without side setback | 50 | 50 | 75 | 100 | 100 | 100 | 100 | 50 | none
adjustment
2 | 2 | 3 | 4 | 6 | 8 | 8 | 2 | 8
Max. no. of stories without side or rear setback
adjustment
Setback Rear | 25 | 25 | 20 | 15 | 15 | 15 | 10 | 20 | none
Rear setback, minimum (ft.) interior lot
10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | none
Rear setback, minimum (ft.) corner lot
average | average | average | average | average | average | average | average | average
Rear street setback, minimum (ft.)
(see s. 295-505-2-e)
none | none | none | none | none | none | none | none | none
Rear street setback, maximum (ft.)
no | no | no | yes | yes | yes | yes | yes | Yes
Multiple principal residential buildings permitted? ****
**** In addition to the principal residential building, one detached accessory dwelling unit is permitted on a parcel in an RM1, RM2 or RM3 district. In the RM4-RM7 districts and the
RO1 and RO2 districts, no new detached accessory dwelling unit is permitted on a parcel that already contains 2 principal residential buildings or a principal residential building and a
detached accessory dwelling unit.
b-5. Required Setback for Addition or Alteration. b-5-a. In a case where portions of the existing structure are closer to the front street lot line than the nearest adjacent buildings, a new addition or alteration may come up to the portion of the structure closest to the front property line.
b-5-b. Where the existing structure is set back farther from the front property line than the nearest adjacent buildings, a new addition or alteration shall be permitted within the front setback range described in subd. 2 or may be placed up to any point between the existing front setback and the setback range.
b-5-c. No structure may be altered by removing a portion of the structure such that the front of the building will no longer be within the allowed setback range, or will be even farther from the permitted range than it already is.
b-6. Atypical Properties. b-6-a. When determining the required setback, the commissioner of neighborhood services shall exclude any building with a setback that exceeds the average setback of other buildings on the blockface by more than 25 percent.
b-6-b. When determining the required setback, the commissioner of neighborhood services shall exclude any building with a setback that is at least 25 percent less that the average setback of other buildings on the blockface if the permit applicant requests such exclusion.
b-7. Exclusion of Non-residential Buildings. When determining the required setback for residential buildings, the commissioner of neighborhood services shall exclude the setbacks of non-residential buildings if the permit applicant requests such exclusion.
b-8. Adjustment Due to Topography. Where a sloping front yard rises at least one foot for every 2 feet of run and application of the maximum front setback requirement would result in the front of the proposed building being placed on the slope or within 10 feet of the crest of the sloping front yard, the maximum front setback may be increased to not more than 10 feet back from the crest of the sloping front yard.
b-9. Exception for All Non-Residential Uses. There shall be no minimum front setback for a principal structure of any non-residential use located on a corner lot.
b-10. Exception for Educational and Community-serving Uses. Principal structures of educational and community-serving uses may be set back a distance greater than the maximum front setback otherwise required.
c. Side Setback Standards. c-1. Minimum Setback for Property Adjacent to Developed Parcels or Alleys. c-1-a. A new principal building on a property that is adjacent to another property containing an existing principal building located closer than 1.5 feet from the shared property line shall maintain a minimum dimension of 3 feet from such existing structure, even when table 295-505-2 allows the new structure to be less than 3 feet from the property line.
c-1-b. Where a side property line abuts an alley, the minimum setback shall be the lesser of the 2 required side setbacks.
c-2. Adjustment for Buildings with Excessive Depth. When a structure exceeds the maximum depth specified in table 295-505-2, as measured from the front façade of the building, 1.5 additional feet of side setback shall be required for each additional 10 feet of building depth. Only the portion of the structure which exceeds the maximum building depth shall be required to have the additional setback. This adjustment shall not apply on the side of a lot that abuts an alley or a side street.
c-3. Adjustment for Buildings with Excessive Number of Stories. As specified in table 295-505-2, 4 additional feet of side setback shall be required on each side for each additional story above the maximum number of stories allowed. Only stories above the maximum story shall be required to have these additional setbacks. This adjustment shall not apply on the side of a building that abuts an alley.
c-4. Attached Housing. When a permitted dwelling unit is attached to another dwelling unit on an adjacent lot, no minimum setback shall be required where a common wall attaching the dwellings is located. Walls of an attached dwelling that are not attached to another dwelling on an adjacent lot shall follow setback standards specified in table 295-505-2.
d. Side Street Setback Standards. d-1. Build-to Line. Where a maximum side street setback is specified, at least 30% of the side street façade shall be located between the minimum and maximum required setbacks.
d-2. Exception for All Non-Residential Uses. There shall be no minimum side street setback for a principal structure of any non-residential use located on a corner lot.
d-3. Exception for Educational and Community-serving Uses. Principal structures of educational and community-serving uses may be set back a distance greater than the maximum side street setback specified in table 295-505-2.
e. Rear Street Setback Standards. e-1. Determination of Required Setback. There shall be no maximum rear street setback. The minimum rear street setback for both new construction and additions to existing structures shall be determined by using the most applicable of the following methods:
e-1-a. Adjacent Structures. Where immediately adjacent lots contain principal or accessory buildings, the rear street setback shall be calculated as the average of the distance between the rear-most façade element or roofed area of the adjacent buildings and the street property line.
e-1-b. No Adjacent Structures. Where one or both of the immediately adjacent lots do not contain buildings, the rear street setback shall be determined by averaging the rear street setbacks of the 2 nearest buildings located on the same blockface, in adjacent blockfaces on the same side of the street, in the blockface across the street or on the nearest similar street, in that order. Buildings included in this calculation may be either principal structures or accessory structures.
e-2. Setback Average and Range. When table 295-505-2 specifies that the minimum rear street setback for a principal building in a residential district shall be determined by averaging, the minimum rear street setback may be anywhere in the range of the average setback minus 20% to the average setback plus 20%.
e-3. Atypical Properties. e-3-a. When determining the required setback, the commissioner shall exclude any building with a setback that exceeds the average setback of other buildings on the blockface by more than 25 percent.
e-3-b. When determining the required setback, the commissioner shall exclude any building with a setback that is at least 25 percent less that the average setback of other buildings on the blockface if the permit applicant requests such exclusion.
e-4. Exclusion of Non-residential Buildings. When determining the required setback for residential buildings, the commissioner shall exclude the setbacks of non-residential buildings if the permit applicant requests such exclusion.
f. Permitted Setback Intrusions. f-1. General. In order for buildings to have various features that provide variety, articulation and unique character, standards are established to allow certain elements of modest size to be placed in setback areas. These standards are found in table 295-505-2-f.
f-2. Porches. As used in table 295-505-2-f, the term “porch” refers to a covered, open-sided protrusion from the principal building. It does not refer to an enclosed porch, which is considered part of the principal building, or to an uncovered porch, which is considered a deck.
g. Intrusions Into Public Right-of-way. See ch. 245 for regulations pertaining to intrusions of structures into the public right-of-way.
h. Building Height. h-1. Compliance with Minimum Height Requirement. At least 50% of a structure’s roof shall meet the minimum height requirement. In the case of a pitched roof, this standard shall be applied to the ridge of the roof. In the case of a flat roof, this standard shall apply to the entire surface area of the roof.
h-2. Exceptions to Height Limitations. All structures shall comply with the height limitations established in each zoning district, except the following:
h-2-a. Chimneys and flues.
h-2-b. Water towers or tanks other than those located on the roof of a building.
h-2-c. Bulkheads, elevator enclosures, penthouses, skylights or water tanks occupying in the aggregate less than 25% of the area of the roof on which they are located.
h-2-d. Parapet walls or cornices extending above the height limit not more than 5 feet.
h-2-e. Monuments, television reception antennae, radio reception antennae, flag poles, spires, church roofs, domes, cupolas or belfries for ornamental purposes and not used for human occupancy.
h-2-f. Religious assemblies, convents, schools, dormitories, colleges, libraries and museums in zoning districts which limit height to 45 or 60 feet. Such a building or portion thereof may exceed the height limit of the district if the building, or portion of the building in excess of the limit, is set back from side lot lines a distance equal to one-half the height of the building or portion thereof.
h-2-g. Transmission towers which are in compliance with the height-related standards of s. 295-503-2-r.
h-2-h. Buildings in the RM7 district which have a floor area ratio of less than 4:1.
h-2-i. Solar farms and solar arrays.
Table 295-505-2-f PRINCIPAL BUILDING INTRUSIONS INTO SETBACK AREAS
Type of Intrusion | Front or Rear Street Setback | Side Street Setback | Side Setback | Rear Setback
Porch | Shall not encroach into required | Shall not encroach into | Up to 4 ft.; however, the porch shall not be | Shall not encroach into required setback; however,
setbacks; however, stairs | required setbacks; | more than 6 ft. wide or be closer than 3 ft. | stairs leading to a porch may encroach.
leading to a porch may | however, stairs leading to | from the side property line and shall be
encroach. | a porch may encroach. | open on all sides.
Permitted in setback only if: 1. The ramp has skirting material to screen the areas beneath the ramp. 2. The ramp is kept in a reasonably good state of repair and maintenance. 3. Trees or shrubs displaced by the ramp shall be relocated or replaced. | Permitted anywhere in rear setback area.
Uncovered
wheelchair ramp
Uncovered | Permitted in setback only if: 1. Skirting with a minimum height of 4 feet is provided. 2. The lift is equipped to prevent lowering if the area beneath the lift is not clear of obstructions. 3. The lift has skirting material which prevents obstructions to the movement of the chair.
wheelchair lift
Permitted anywhere in a setback area, but shall not exceed 4 feet in height.
Planter
Air-conditioning | Not permitted unless set back at least 50 feet and entirely screened. | Not permitted unless the use on the adjacent lot is non-residential or unless any dwelling on the adjacent lot is at least 15 feet from the lot line. | Permitted anywhere in rear setback area.
condenser
Hood or awning | Up to 6 feet | Up to 6 feet | Up to 4 feet, but not closer than 2 feet from any property line
Eave | Up to 4 feet | Up to 4 feet | Up to 2 feet, or one-half of the required setback, whichever is less. | Up to 4 feet, but not closer than 2 feet from any property line.
Balcony | Up to 4 feet | Up to 4 feet | Not permitted | Up to 4 feet, but not closer than 2 feet from any property line.
Fire escape | Not permitted | Not permitted | Permitted only along a side facing an alley | Up to 6 feet, but not closer than 2 feet from any property line
Bay window | Up to 6 feet in width and 30 inches in projection, but never closer than 18 inches from a side property line. Not more than one-third of the facade may have similar protrusions.
Chimney | Up to 6 feet in width and 30 inches in projection, but never closer than 18 inches from a side property line.
h-3. Airports. In any area within the city where the height limitations of the Milwaukee county airport approach height ordinances are applicable, such height limitations shall apply, except where the height limitations of this chapter are more restrictive. Exceptions permitted under s. 200-44 and objects of natural growth shall not exceed the height limitations established by the Milwaukee county general ordinances and by s. 114.136, Wis. Stats.
i. Lot Coverage. i-1. The lot coverage standards set forth in table 295-505-2 relate to the proportion of a lot occupied by principal buildings. Accessory structures shall not be included when determining principal building lot coverage.
i-2. Table 295-505-2-i provides minimum building height and minimum front façade width requirements that are to be applied, in certain zoning districts, in place of the lot coverage standards of table 295-505-2. The standards in table 295-505-2-i apply only to single-family, 2-family and multi-family dwellings.
i-3. For any interior lot in an RS4, RS5 or RS6 zoning district, the maximum lot coverage for a residential use or group residential use shall be as follows:
i-3-a. If the area of the lot is less than or equal to 1.3 times the average lot area of other lots on the blockface that are occupied by residential or group residential uses, the maximum lot coverage shall be as specified in table 295-505-2.
i-3-b. If the area of the lot is more than 1.3 times the average lot area of other lots on the blockface that are occupied by residential or group residential uses, the maximum lot coverage shall be 60% of the maximum lot coverage specified in table 295-505-2.
i-4. For any corner lot in an RS4, RS5 or RS6 zoning district, the maximum lot coverage for a residential use or group residential use shall be as follows:
i-4-a. If the area of the lot is less than or equal to 1.3 times the average lot area of other lots on both blockfaces that are occupied by residential or group residential uses, the maximum lot coverage shall be as specified in table 295-505-2.
i-4-b. If the area of the lot is more than 1.3 times the average lot area of other lots on both blockfaces that are occupied by residential or group residential uses, the maximum lot coverage shall be 60% of the maximum lot coverage specified in table 295-505-2.
j. Multiple Principal Buildings. j-1. Intent. Standards for properties with more than one principal building are established to recognize the various contexts in which this type of development occurs and to allow practical use and improvement of such properties. More than one principal residential building shall be permitted on a lot only as provided in table 295-505-2. Multiple principal non-residential buildings shall be permitted in all residential zoning districts. The standards of this paragraph apply to both multiple principal residential buildings and multiple principal non-residential buildings.
j-2. Distance Between Buildings. The front-to-back minimum distance between 2 principal residential buildings shall be 10 feet. The side-to-side minimum distance between 2 principal residential buildings shall be 5 feet. There shall be no required minimum distance between 2 principal non-residential buildings.
j-3. Side Setback. The minimum side setback shall be as specified in table 295-505-2.
j-4. Rear Setback. Where the rear of a property abuts an alley, the minimum rear setback shall be 4 feet, regardless of the requirement specified in table 295-505-2.
j-5. Lot Coverage. On a parcel having multiple principal residential buildings or an accessory dwelling unit, in the RS1 to RS5 and RT1 to RT3 districts, maximum lot coverage may be increased by up to an additional 15%. In the RT4 and RS6 districts, a parcel having multiple principal residential buildings or an accessory dwelling unit, maximum lot coverage may be increased by up to an additional 15% as long as the accessory structure lot coverage is reduced by a corresponding amount.
k. Conversion of Non-Residential Buildings to Residential Use. A non-residential building may be converted to residential use. The density regulations of table 295-505-2 shall be applicable to any such conversion. Where the conversion would otherwise be prohibited by these density regulations, each existing non-residential unit may be converted to one residential unit.
L. Design Features. L-1. Intent. The standards of this paragraph are intended to enable a residential building to be compatible with its context, as well as to encourage pedestrian-oriented residential development.
L-2. Entrance Door Orientation.
L-2-a. Standard. Every new principal building shall have a primary entrance door that faces a street.
Table 295-505-2-i MINIMUM RESIDENTIAL BUILDING FRONT FACADE WIDTH AND BUILDING HEIGHT
Lot width (ft.) | Min. building height (ft.)
Min. building front | Min. no. of
facade width (ft.) | stories *
25 | No requirement | 1 | 20
30 | No requirement | 1 | 20
31 | No requirement | 1 | 20
32 | No requirement | 1 | 20
33 | No requirement | 1 | 20
34 | No requirement | 1 | 20
35 | 20 | 1 | 20
36 | 22 | 1 | 20
37 | 22 | 1 | 20
38 | 24 | 1 | 20
39 | 24 | 1 | 20
40 | 24 | 1 | 20
41 | 24 | 1 | 20
42 | 24 | 1 | 20
43 | 24 | 1 | 20
44 | 24 | 1 | 20
45 | 24 | 1 | 20
46 | 26 | 2 | 25
47 | 28 | 2 | 25
48 | 30 | 2 | 25
49 | 30 | 2 | 25
50 | 32 | 2 | 25
51 | 32 | 2 | 25
52 | 34 | 2 | 25
53 | 34 | 2 | 25
54 | 34 | 2 | 25
55 | 36 | 2 | 25
56 | 36 | 2 | 25
57 | 38 | 2 | 25
58 | 38 | 2 | 25
59 | 40 | 2 | 25
60 | 40 | 2 | 25
More than 60 | Width X 0.65 | 2 | 25
* If the structure is adjacent to a lot containing a one-story house, a one-story structure shall be permitted
regardless of the width of the lot on which it is located.
L-2-b. Multi-Family Use. Every new multi-family building with common hallways to access units shall have a primary entrance door on a front façade or a side street façade, even if other doors serving individual townhouse-style units, or other uses, are present. The main entrance used by residents and visitors, as well as the door where mail is delivered and deliveries are made, is considered the primary entrance of a multi-family residential use. This requirement shall not apply to a building where all units have direct access to the exterior, such as a townhouse building, and a pedestrian path that connects to a public sidewalk in accordance with s. 295-505-4-d-1.
L-2-c. Exception. A new principal building may have an entrance door that does not face a street if the building or building site includes physical features that clearly identify the location of the front entrance of the building and are readily visible from the public right-of-way. Examples of such features include, but shall not be limited to, covered stoops, porches, retaining walls and masonry planters.
L-3. Overhead Garage Doors Facing Streets. For any new building constructed in the RS6, RT3, RT4, RT5 and RM3-RM7 districts, an attached garage which has an overhead garage door that faces the street shall be set back at least 4 feet from the street façade of the main building mass. The following exceptions shall apply:
L-3-a. An overhead garage door may be flush with the street façade of the building if the building has a porch, floor-to-ceiling bay window, balcony, hood, canopy, integral planter, landscaping wall or other significant design feature or combination of features which extend at least 4 feet forward from the wall plane on which the door is placed. A garage door which is recessed within the thickness of the garage wall as a result of typical construction practices shall be considered “flush.”
L-3-b. An overhead garage door may be flush with the street façade of the building if at least 40% of the façade on which the door is located is comprised of windows.
L-4. Restricted Building Wall Materials. Unless otherwise noted herein, the following regulations apply to any non-industrial principal building or addition:
L-4-a. Metal Building Walls. The use of structural corrugated metal wall, or a metal panel-and-batten wall system such as a metal-sided, prefabricated building or a pre-engineered metal building, shall be prohibited when located on any front façade or street façade located within 100 feet of a street lot line. An architectural metal panel façade system with integral trim and integral trim connections to adjacent materials is permitted provided that the architectural metal panel system is not used closer than 1.5 feet from the ground.
L-4-b. Concrete Masonry Units. Utility-grade concrete masonry units, such as standard concrete block and split-face block, are permitted along a building’s street-facing frontage provided that their use is limited to the base of the façade to a height not exceeding 2.5 feet. These materials are permitted on a building’s rear, alley and interior lot line facades. This subparagraph shall not apply to a single- or 2-family dwelling.
L-4-c. Simulated Stucco Products. Simulated stucco products are prohibited on the ground-level area of a building, and may only be used on the upper one-third of a street façade. These materials are permitted on floors above the ground level on a building’s rear, alley and interior lot line facades. For purposes of this subparagraph, the ground-level area of a one-story building is the lowest 12 feet of the building. This subparagraph shall not apply to a single- or 2-family dwelling.
L-4-d. Prohibited Stone Cladding. Masonry stone cladding using irregularly-shaped stones, often known as rubble masonry and which is typically laid in an un-coursed manner, is prohibited. This prohibited stone cladding may be composed of river rock of smooth oval-shaped stones or of rough, thinly-layered courses commonly known as ledgestone. Prohibited materials may be natural stone, manufactured or cultured stone, or veneer siding material. This subparagraph shall not apply to a single- or 2-family dwelling.
L-4-e. Fiber-Cement Siding. Fiber-cement siding, including composite material made of cement reinforced with cellulose fibers, or any material that is the equivalent of fiber-cement siding, is prohibited within 1.5 feet of grade on a street façade that is adjacent to a street lot line or sidewalk. This subparagraph shall not apply to a single- or 2-family dwelling.
L-5. Exterior Fire Escape Stairs. Fire escape stairs are not permitted above the second floor on the façade facing the street of a residential building with one to 4 dwelling units.
m. Garage Door Setback. Garage doors shall be set back a minimum of 4 feet from alley lot lines.
n. Minimum Lot Area for Premises with Mixture of Dwelling Unit Types. n-1. Permanent Supportive Housing. Where permanent supportive housing is mixed with other types of dwelling units, the calculation of lot area per dwelling unit first requires that the lot area be prorated between the different housing types according to the number of units of each type, using the formula PSF = ((PN/RN) x LSF)/PN, where:
n-1-a. PSF is the lot area, in square feet, per permanent supportive housing unit.
n-1-b. PN is the number of permanent supportive housing units.
n-1-c. RN is the total number of residential units both permanent supportive housing units other types of dwelling units.
n-1-d. LSF is total lot area, in square feet.
Table 295-505-2.5 ACCESSORY DWELLING UNIT DESIGN STANDARDS
Internal Accessory | Attached Accessory | Detached Accessory
Dwelling Unit | Dwelling Unit | Dwelling Unit
Floor area, minimum | 300 sq. ft. | 300 sq. ft. | 300 sq. ft.
Floor area, maximum | 1,000 sq. ft., but not larger than the largest dwelling unit; may exceed 1,000 sq. ft. if structure existed as of the effective date of this ordinance [August 2, 2025]; shall be located entirely on one level and shall not exceed the area of the first floor. | 1,000 sq. ft., but not larger than the largest dwelling unit. | 1,300 sq. ft. of habitable and parking areas on all levels, or 16% of the lot area, whichever is greater, but not to exceed 1,600 sq. ft. or the floor area of the largest dwelling unit.
Height, minimum | none | none | none
Height, maximum | Same as principal building. | Same as principal building. | Not greater than the height of the principal building on the parcel.
Front setback, minimum | Same as principal building. | Same as principal building. | Not less than the front setback of the principal building on the parcel.
Side setback, minimum | Same as principal building. | Same as principal building. | 3 ft.
Rear setback, minimum | Same as principal building. | Same as principal building. | 4 ft. from the alley lot line if the accessory dwelling unit building includes a garage with an overhead door facing the alley; 3 ft. if the accessory dwelling unit does not include a garage or includes a garage but the overhead door does not face the rear lot line.
Distance from main dwelling, minimum | Not applicable. | Not applicable. | The front-to-back minimum distance between the 2 buildings shall be 10 ft. The side- to-side minimum distance between the 2 residential buildings shall be 5 ft.
Pedestrian connections to street frontage | An accessory dwelling unit entry within a rear or side yard shall be connected to a street frontage by a paved walkway or access drive. | An accessory dwelling unit entry within a rear or side yard shall be connected to a street frontage by a paved walkway or access drive. | An accessory dwelling unit entry within a rear or side yard shall be connected to a street frontage by a paved walkway or access drive.
Balconies and decks | Same as principal building. | Same as principal building. | Same as principal building.
Table 295-505-3 ACCESSORY STRUCTURE DESIGN STANDARDS
Deck/stoop less | Deck/stoop one to | Deck/stoop more
than one foot | 3 feet above | Deck/stoop 3 to 7 feet | than 7 feet above | Pergola, trellis | Open pavilion
Garage | Shed | above grade | or arbor
above grade | grade | grade
Included in lot
Yes | Yes | No | No | Yes | Yes | No | Yes
coverage calculation?
Minimum front setback | Same as principal | Same as | No restriction. | Same as | Same as | Same as | No restriction. | Same as
building; if the | principal | principal | principal | principal | principal
garage door faces | building. | building. | building. | building. | building.
the front of the lot,
an additional
4 ft. shall be
required.
Minimum side street | Same as principal building, but not | No restriction. | Same as principal building. | Same as | No restriction. | No restriction.
setback | closer to side street than any existing | principal
principal building. | building.
Minimum rear street | Average in accordance with s. 295-505-2-e. | No restriction. | No restriction. | Average in
setback | accordance with
s. 295-505-2-e.
Minimum side setback | Same as | Same as | No restriction. | Up to property | 1.5 feet; | Same as | Same as | Same as
when located in the | principal | principal | line; however, | however, all | principal | principal | principal
side yard | building. | building. | all railings | railings above | building. | building. | building.
above 4 feet | 4 feet shall be
shall be at | at least 50% open.
least 50% open.
Minimum side setback | 1.5 feet; 4 feet if access crosses side lot line from an alley. | 1.5 feet. | No restriction. | No restriction. | 1.5 feet; however, all railings above 4 feet shall be at least 50% open. | 1.5 feet; however, all railings above 4 feet shall be at least 50% open. | No restriction. | 1.5 feet.
when located in the
rear yard
Table 295-505-3 ACCESSORY STRUCTURE DESIGN STANDARDS
Deck/stoop less | Deck/stoop one to | Deck/stoop more
Deck/stoop 3 to 7 feet | Pergola, trellis
Garage | Shed | than one foot | 3 feet above | than 7 feet above | Open pavilion
above grade | or arbor
above grade | grade | grade
Minimum rear setback | 4 feet; may be reduced to 1.5 feet if there is no alley or no access from an alley. | 4 feet; may be reduced to 1.5 feet if there is no alley or no access from an alley. | No restriction. | No restriction. | 1.5 feet; however, all railings above 4 feet shall be at least 50% open | 4 feet; may be reduced to 1.5 feet if there is no alley. | No restriction. | 1.5 feet.
Maximum height | 10 feet** | 8 feet. | No restriction. | No restriction. | No restriction. | 10 feet. | 8 feet. | Not applicable.
of sidewall
Maximum overall height | 24 feet or the height of the principal building, whichever is less. | 14 feet. | Not applicable. | Not applicable. | Not applicable. | 14 feet | 14 feet | 10 feet*
*Maximum overall height for an open pavilion that is accessory to a permitted non-residential use shall be 14 feet or the height of the principal building, whichever is less.
**Sidewall height may be increased by up to 2 feet on the down-sloped side of the sloped lot.
n-2. Transitional Housing. Where transitional housing is mixed with other types of dwelling units, the calculation of lot area per dwelling unit first requires that the lot area be prorated between the different housing types according to the number of units of each type, using the formula TSF = ((TN/2)/((TN/2) + GN)) x LSF)/TN, where:
n-2-a. TSF is the lot area, in square feet, per transitional housing client
n-2-b. TN is the total number of transitional housing clients
n-2-c. GN is the total number of dwelling units, not including transitional housing
n-2-d. LSF is total lot area, in square feet
2.5. ACCESSORY DWELLING UNITS. The design standards for accessory dwelling units are set forth in table 295-505-2.5.
3. ACCESSORY STRUCTURE STANDARDS. a. Introduction. The design standards for accessory structures in residential districts are set forth in table 295-505-3. These standards apply to accessory structures of permitted non-residential uses in residential districts, as well as to structures which are accessory to residential buildings. The provisions of this subsection explain, qualify or specify exceptions to the standards in the table.
b. Principal Building Required. No accessory building shall be located on a lot not containing a principal building, unless the principal use of the lot is for the raising of livestock, a community garden or a commercial farming enterprise. If a principal building on a lot is removed, any accessory building on the lot shall also be removed within 60 days and the premises made compliant with this code.
c. Maximum Lot Coverage. See table 295-505-3 to determine which structures shall be included when calculating the lot coverage of accessory structures. The total lot coverage of all accessory structures which are subject to inclusion in the lot coverage calculation shall not exceed 15% of the lot area. Total lot coverage may be increased to 22% if at least 7% of the coverage is for an open pavilion.
d. Maximum Number. Not more than 2 accessory buildings may be located on a single lot.
e. Maximum Size. For any lot occupied solely by a single-family or 2-family dwelling, no garage or deck shall exceed 1,000 square feet in area and no open pavilion shall exceed 500 square feet in area.
f. Garages and Sheds. f-1. General. An accessory building that is 150 square feet or less in area shall meet the requirements for sheds set forth in table 295-505-3. An accessory building that is greater than 150 square feet in area shall meet the requirements for garages set forth in table 295-505-3. A carport or similar roofed structure shall meet the requirements for either garages or sheds, depending on the size of the structure.
f-2. Location. A garage or shed may be located in the rear yard of the principal structure. A garage or shed may also be located in the side yard, provided it is not in the required side setback area of the principal structure. Garages and sheds shall not be permitted in front yards.
f-3. Roof Overhang. A roof overhang may project into a required setback area up to one-third of the required setback. Gutters shall not be considered part of a roof overhang.
f-4. Dormers. Dormers shall be permitted provided that, in the aggregate, they are no wider than half of the length of the roof, begin no closer than 4 feet from either of the gable ends and have a roof pitch of at least 3:12.
f-5. Sidewall Height. The maximum height of a garage or shed sidewall shall be as specified in table 295-505-3. The height of a sidewall shall be measured from the level of the grade to a horizontal line even with the bottom edge of the fascia board. Where rafter tails are exposed, measurement shall be to a horizontal line even with the bottom edge of the rafters.
f-6. Parapet Walls. A parapet wall on a flat-roofed garage may extend up to 4 feet above the permitted sidewall height.
f-7. Rooftop Decks. Railings for a rooftop deck may extend up to 3.5 feet above the maximum sidewall height if they are at least 50% open. Portions of a parapet wall may also extend up to 3.5 feet above the permitted sidewall height if these sections are no wider than half the width of the side of the garage on which they are located.
f-8. Roof Type. A shed may have a gambrel-style roof. A garage may have a gambrel-style roof only if the principal building has a gambrel-style roof. When a gambrel-style roof is used, its pitch shall be similar to the roof pitch of the principal building.
f-9. Attachment to Principal Building. A garage or shed may be attached to a principal building. If an attached garage or shed has no second-floor living space, it shall be included in the lot coverage calculation for accessory structures, rather than the lot coverage calculation for the principal building. In addition, an attached garage or shed with no second-floor living space shall be subject to the setback requirements for an accessory building, rather that the setback requirements for a principal building.
f-10. Exception for Small Lots. Notwithstanding the limitations of subd. 1, a garage shall be permitted to have an area of at least 484 square feet.
g. Uncovered Wheelchair Lifts and Ramps. Uncovered wheelchair lifts and ramps shall be permitted within required setback areas in accordance with the provisions of table 295-505-2-f. Adjacent deck areas shall also be in compliance with the applicable provisions of this table. Uncovered wheelchair lifts and ramps shall not be included in the calculation of lot coverage of accessory structures.
h. Decks and Stoops. h-1. General. Decks and stoops shall meet the requirements set forth in table 295-505-3. Decks and stoops are classified into the following 4 categories on the basis of height above grade:
h-1-a. At grade to not more than one foot above grade.
h-1-b. More than one foot above grade to not more than 3 feet above grade.
h-1-c. More than 3 feet above grade to not more than 7 feet above grade.
h-1-d. More than 7 feet above grade.
h-2. Exception. Notwithstanding the requirements of table 295-505-3, a principal building may have a deck or stoop up to 3 feet above grade in the front or side street setback provided the area of the deck or stoop does not exceed 25 square feet.
h-3. Stairs. Stairs leading to a permitted deck, stoop or building entrance may be located in a required setback area.
h-4. Deck Skirting. Skirting to screen the area underneath the deck shall be provided for any deck that is more than 2 feet above grade. Skirting shall not be required if any of the following are true:
h-4-a. The deck is more than 30 feet from any property line.
h-4-b. The deck is located within 3 feet of a property line and an opaque fence at least 4 feet high is present or is constructed along that property line such that the view of the deck from the neighboring property or public way is obscured.
h-4-c. The area adjacent to the deck is landscaped with plantings that obscure the view of the underside of the deck from the neighboring property or public way.
i. Open Trellises and Arbors. An open trellis or arbor may be located in the front yard, side yard or rear yard in accordance with table 295-505-3.
j. Children’s Playhouse. A playhouse shall not be subject to any of the regulations of this subsection, except that no playhouse shall be located in the front yard or the required side setback.
k. Swimming Pools. An in-ground or above-ground swimming pool shall not be subject to any of the regulations of this subsection, except that no swimming pool shall be located in the front yard or the required side setback.
L. Mechanical Equipment. L-1. Permitted Equipment. Mechanical equipment such as, but not limited to, air-conditioning condensers, satellite dishes and utility boxes shall be permitted only in portions of side yards and rear yards outside required setback areas. Air conditioning condensers may also be placed in the required setback areas of principal buildings to the extent allowed by table 295-505-2-f.
L-2. Wood-burning Furnaces. Because of their potential to create adverse off-site effects, outdoor wood-burning furnaces are prohibited in all residential districts.
m. Portable Moving and Storage Containers. No portable moving and storage container shall be placed on a lot in a residential zoning district for more than 30 days.
n. Chicken Coops. Chicken coops, under s. 78-6.5, shall not be subject to any of the regulations of this subsection if the covered portion of the coop is 50 square feet or less in size and 10 feet or less in height.
o. Solar Arrays. A ground-mounted solar array that is more than 20 feet in height shall comply with the setback regulations for a principal building. A ground-mounted solar array that is 20 feet or less in height shall comply with the front setback requirement and be set back a minimum of 1.5 feet from all side, side street and rear lot lines.
p. Accessory Structures for Agricultural Uses. p-1. Permitted Structures. The following accessory structures supporting the raising of livestock, a community garden or a commercial farming enterprise shall be permitted:
p-1-a. Sheds.
p-1-b. Large agricultural structures.
p-1-c. Hoop houses.
p-2. Maximum Number. Not more than one shed and one large agricultural structure may be located on a single lot. The number of hoop houses on a single lot is unlimited.
p-3. Lot Coverage. The total lot coverage of all sheds, large agricultural structures and hoop houses on a single lot shall not exceed 70% of lot area. The total lot coverage of sheds and large agricultural structures on a single lot shall not exceed 15% of lot area.
p-4. Setbacks. p-4-a. The minimum front setback, side street setback or rear street setback for a shed, large agricultural structure or hoop house shall be the average plus 5 feet.
p-4-b. The minimum side setback or rear setback for a shed, large agricultural structure or hoop house shall be 5 feet.
p-5. Maximum Height. p-5-a. The maximum height of the sidewall of an agricultural accessory structure shall be 8 feet for a shed, 10 feet for a large agricultural structure and 14 feet for a hoop house.
p-5-b. The maximum overall height of an agricultural accessory structure shall be 10 feet for a shed, 14 feet for a hoop house, 14 feet for a large agricultural structure on a vacant lot, and 24 feet or the height of the principal building for a large agricultural structure on a lot containing a principal building.
q. Other Accessory Structures. Miscellaneous accessory structures shall meet the requirements applicable to the most similar accessory building or site feature for which requirements have been established.
4. SITE STANDARDS. a. Applicability. Unless otherwise noted, the provisions of this subsection apply to all residential and non-residential uses.
b. Parking Spaces. b-1. General. Off-street parking spaces for uses in residential zoning districts shall be provided in accordance with the requirements of s. 295-403-2 and shall meet the design standards of s. 295-403-3.
b-2. Reduction Prohibited. The number of parking spaces provided for a use in a residential zoning district shall not be reduced below the number required by s. 295-403-2.
b-3. Location of Parking Spaces. Parking spaces may be located in a rear yard or the portion of a side yard that is beyond the required setback. Parking spaces shall not be located within the front yard or in the side setback, rear street setback or side street setback of the principal building.
b-4. Maximum Number of Vehicles. Not more than 4 motor vehicles may be parked outdoors on a lot containing a single-family, 2-family dwelling or community living arrangement with 8 or fewer clients.
b-5. Commercial Vehicles. Not more than one commercial vehicle may be parked on a lot in a single-family, 2-family or multi-family zoning district.
b-6. Recreational Vehicles. Not more than one recreational vehicle, other than a motorcycle or snowmobile, may be parked on a lot in a single-family, 2-family or multi-family district.
b-7. Maximum Vehicle Length, Vehicle Height and Number of Wheels. No vehicle in excess of 22 feet in length, or in excess of 10 feet in height or with more than 6 wheels may be parked on a lot in a single-family, 2-family or multi-family district.
b-8. Tow Trucks. No tow truck may be parked on a lot in a single-family, 2-family or multi-family zoning district unless the tow truck is parked inside a building.
b-9. Unregistered Vehicles. No motor vehicle lacking valid license plates shall be parked for a period exceeding 30 days outside any structure or lot used in whole or in part for residential purposes.
c. Access Drives. c-1. Location. An access drive leading to parking spaces in a permitted rear-yard or side-yard location may be located in a required setback area. An access drive which leads to permitted parking spaces may also be used for parking, but any such parking shall not count toward the parking-space requirements of s. 295-403-2. An access drive may be placed directly adjacent to an interior side property line.
c-2. Configuration. An access drive shall generally traverse the front property line at a right angle. The commissioner of public works shall approve the location and design of the curb cut and driveway apron for the access drive.
c-3. Width. The width of the access drive serving a parcel containing 8 or fewer dwelling units shall not exceed 18 feet where the access drive intersects with the public right-of-way. An access drive traversing the side yard to a permitted parking area of a residential building shall not exceed 18 feet in width. An access drive leading to an overhead garage door facing the street shall be not more than 2 feet wider, on each side, than the door being served.
c-4. Shared Drives. For any single-family or 2-family dwelling, an access drive to the abutting public street may be shared with an adjoining single-family or 2-family dwelling provided there exists a recorded legal instrument which guarantees access to the drive for occupants of each dwelling served by the shared drive and which assigns responsibility for maintenance of the drive.
c-5. Limit on Number of Drives. For a parcel with 8 or fewer dwelling units, not more than one access drive shall be permitted along any street frontage of the parcel.
d. Pedestrian Access. d-1. General. Where a lot is adjacent to a public sidewalk, each principal building on the lot shall be served by a clearly identifiable walkway leading from the public sidewalk to the entrance to the building. The presence of an access drive does not fulfill this requirement.
d-2. Paving. All required pedestrian access ways shall be paved with non-asphalt materials.
d-3. Width. All required pedestrian access ways shall be at least 3 feet in width.
e. Landscaping. e-1. Intent. Landscaping shall be designed as an integral part of any development in a residential zoning district. As in commercial and industrial zoning districts, parking lots, dumpsters and other unsightly site features shall be screened such that they are not visible from public streets and neighboring residential properties.
e-2. Parking Lots. All uses, with the exception of single-family and 2-family dwellings, shall provide parking lot landscaping in accordance with s. 295-405.
e-3. Containers Used for Solid Waste Disposal. Every use, except a residential building containing 4 or fewer dwelling units, shall provide an area for all dumpsters or other containers used for solid waste disposal, including containers for recycled materials. Containers used for solid waste disposal shall meet the following location and screening requirements:
e-3-a. On-site Location. All containers, including dumpsters, shall be provided on-site for all uses contained within a building. This location may be in an indoor location on the premises or in an outdoor location that complies with the screening requirements of s. 295-405-6.
e-3-b. Alternatives to On-Site Location. An off-site container or dumpster area location may be provided if the applicant submits documents acceptable to the department of neighborhood services showing that the applicant has entered into an agreement with an adjacent property owner for access to containers or dumpster areas that meet the screening requirements of s. 295-405-6. Alternatively, an off-site container or dumpster area location may be provided if the applicant has applied for a special privilege to place solid waste and recycled material storage containers in the public right-of-way pursuant to s. 245-12 and the commissioner of public works has found that the criteria for recommending approval of a special privilege have been met.
e-3-c. Plan Submittal. Prior to the issuance of construction or alteration permits for a new use or a substantial improvement of an existing building, dumpsters or other containers used for solid waste disposal, including containers for recycled materials, and the screening for these containers, if required, shall be shown on submitted plans.
f. Fences. f-1. General. Fences shall be permitted anywhere on a lot in a residential zoning district, including along property lines. For purposes of this paragraph, the term “fence” shall include a wall or similar structure.
f-2. Fences in Front Yards. A fence located in a front yard shall not exceed 4 feet in height. However, an ornamental metal fence may be erected to a height of 6 feet. Such ornamental fence may include piers constructed of masonry, wood or other approved materials, provided the fence is at least 50% open overall. An ornamental metal fence may also be constructed atop a masonry wall provided the combined height of the wall and fence does not exceed 6 feet and the portion of the wall/fence structure above 4 feet high is at least 50% open.
f-3. Fences in Side Yards. A fence located in a side yard shall not exceed 4 feet in height. However, a fence may be erected to a height of 6 feet if the entire fence is constructed of chain link, wrought iron or similar open construction or if the area above 4 feet high is at least 50% open. An example of the latter is a fence that is opaque to a height of 4 feet and is topped with not more than 2 feet of wood lattice. Any side-yard fence may be erected to a height of 6 feet if it is located more than 10 feet from a side lot line.
f-4. Fences in Rear Yards. A fence located in a rear yard may be erected to a height of 6 feet. However, if the fence is located along a side street or rear street, it shall also comply with subd. f-5.
f-5. Fences Along Side Streets and Rear Streets. A fence located along a side street or rear street property line shall not exceed 4 feet in height, with the following exceptions:
f-5-a. A fence may be erected along the side street of a rear yard to a height of 6 feet. In no case does this provision allow a fence to be erected in the public right-of-way, unless the fence has been erected in accordance with the applicable provisions of ch. 245.
f-5-b. An ornamental fence may be erected to a height of 6 feet. Such fence may include masonry piers, provided the fence is at least 50% open overall. An ornamental metal fence may also be constructed atop a masonry wall, provided the combined height of the wall and fence does not exceed 6 feet and the portion of the wall/fence structure above 4 feet high is at least 50% open.
f-6. Fences Enclosing Swimming Pools. A fence which encloses a swimming pool shall also comply with all department of neighborhood services rules and regulations for swimming pools.
f-7. Higher Fences on Abutting Properties. Where a fence is located along a lot line that abuts another property, and a higher fence is permitted directly across the property line on that property, the fence may be erected to the height permitted on the abutting property. Where a retaining wall exists at or adjacent to a property line and the neighboring property has a higher grade, the fence height may be measured to a height allowed on that higher property.
f-8. Fences at Construction Sites. Notwithstanding any other provisions of this paragraph, fences not exceeding 9 feet in height may be erected around construction sites and shall be removed immediately upon completion of the project.
f-9. Fences at Sports Facilities. Notwithstanding any other provision of this paragraph, the commissioner of neighborhood services may permit a fence in excess of 6 feet in height in specific locations on a premises to prevent balls and other objects from damaging adjoining buildings or premises.
f-10. Fences as Part of Required Screening. Notwithstanding any other provisions of this paragraph, a fence may be erected to the height necessary to comply with the screening requirements of s. 295-405.
f-11. Orientation of Supporting Members. The vertical and horizontal supporting members of a fence shall face the interior of the lot on which the fence is located.
f-12. Fence Gates and Trellises. At a gate, walkway or other entrance area, a decorative gate or trellis may extend above the permitted fence height to a maximum of 10 feet in height. A decorative gate or trellis shall not exceed 6 feet in width.
f-13. Fences or Retaining Walls Extending into Public Right-of-Way. A fence or retaining wall may extend into the public right-of-way to the extent allowed by, and only in accordance with, the provisions of ss. 245-4.5 and 245-4.6 or a special privilege granted by the common council pursuant to s. 245-12.
f-14. Prohibited Fence Materials. Barbed-wire, concertina-wire and razor-wire fences are prohibited.
g. Vision Triangles. A fence or other opaque or semi-opaque object located near the intersection of a street with an alley, access drive or other street shall comply with the vision triangle regulations of s. 295-405-1-g.
h. Lighting. The regulations for lighting in residential zoning districts are set forth in s. 295-409.
Table 295-505-5 RESIDENTIAL DISTRICT SIGN STANDARDS *
Elementary and secondary schools, colleges and religious assembly | All other permitted uses, nonconforming commercial uses and board-approved uses. Does not include single-family, 2-family and 3-family dwellings, family day care homes and bed and breakfast establishments
Freestanding Signs | permitted | permitted
Maximum number | 1 per street frontage | 1 per site**
Type “A” max. display area (sq. ft.) | 64*** | 24
Type “B” max. display area (sq. ft.) | 32 | 18
Maximum height | 6 | 6
Wall Signs | permitted | permitted
Maximum number | 1 per principal building | 1 per street frontage
Type “A” max. display area (sq. ft.)) | No limit | 50
Type “B” max. display area (sq. ft.) | 18 | 25
Projecting Signs | permitted | permitted
Maximum number | 1 per principal building | 1 per principal building
Type “A” max. display area (sq. ft.) | 24 | 50
Type “B” max. display area (sq. ft.) | 12 | 25
Awning Signs | type “A” permitted | type “A” permitted
only | only
Maximum number | 1 per principal building | 1 per principal building
Type “A” max. display area (sq. ft.) | 10 | 20
Canopy and Hood Signs | permitted | permitted
Maximum number | 1 per principal building | 1 per street frontage
Type “A” max display area (sq. ft.) | 24 | 50
Type “B” max. display | 12 | 25
area (sq. ft.)
Roof Signs | not permitted | not permitted
Off-premise Signs | not permitted | not permitted
*Signs in the RO1 and RO2 districts shall comply with the sign standards for the NS1 and NS2 districts, respectively. **See s. 295-505-5-b-2 for bonus provision for multi-family dwellings. ***See s. 295-505-5-c-2 for bonus provision for display area
5. SIGNS. a. General. The design standards for signs in residential districts, except RO1 and RO2 districts, shall be based on the use of the property, as set forth in table 295-505-5. As described in s. 295-407, signs are divided into 2 categories, type “A” and type “B.” General standards for each of these categories are found in s. 295-407. The provisions of this subsection explain, qualify or specify exceptions to the standards in table 295-505-5, which pertain specifically to type “A” and type “B” signs in residential zoning districts.
b. Signs for Dwellings. b-1. Single-family, 2-family and 3-family Dwellings. Except for permitted temporary signs, no other signage shall be allowed.
b-2. Multi-family Dwellings. Internally illuminated signs shall be prohibited.
b-3. Bonus Provision for Freestanding Signs. For a multi-family dwelling the maximum number of signs shall be one per street frontage if both of the following are met:
b-3-a. The premises has at least 180 feet of continuous street frontage.
b-3-b. The premises has a lot size of greater than 20,000 square feet.
c. Elementary and Secondary Schools, Colleges and Religious Assembly. c-1. Changeable Message Signs. Changeable message signs, both automatic and manual, shall be permitted
c-2. Bonus Provision for Freestanding Signs. The maximum display area for a freestanding sign at an elementary or secondary school, college or religious assembly may be increased by up to 50% if the following conditions are met:
c-2-a. Not more than one freestanding sign may be erected on the premises.
c-2-b. The premises shall have at least 180 feet of continuous street frontage.
c-2-c. The base of the sign shall be at least as wide as the display surface of the sign.
c-2-d. Any illumination directed at the sign shall be shielded so that the source of illumination is not visible from any property line.
c-2-e. The sign shall be set back at least 30 feet from any residential use.
d. Family Day Care Homes. Signs shall not be permitted.
e. Bed and Breakfast Establishments. A bed and breakfast establishment may have one internally-illuminated sign or one externally-illuminated type “B” sign, provided the sign does not exceed 6 square feet in area.
f. Signs in the RO1 and RO2 Districts. All signs in the RO1 district shall comply with the sign standards for the NS1 district. All signs in the RO2 district shall comply with the sign standards for the NS2 district.
g. Construction or Vacant Land. A sign pertaining to the construction of a building or the sale or lease of vacant land shall not exceed:
Zoning District Max. Sign Area
RS1-RS6 36 sq. ft. RT1-RT5 36 sq. ft. RM1-RM3 36 sq. ft. RM4-RM6 48 sq. ft. RM7, R01-R02 72 sq. ft.
h. Sale or Lease of Improved Real Estate. A sign to advertise the sale or lease of a building or other improved real estate shall be permitted provided it does not exceed 6 square feet in area.
i. Vision Triangles. All signs in residential districts shall comply with the vision triangle regulations of s.295-405-3.
j. Additional Regulations. See s. 295-407 for additional regulations for on-premise signs.