§ 5-2047 — THIRD-PARTY INSPECTIONS AND REPORTING SYSTEM

Code of the City of Raleigh (Supp. No. 69: codified through Ordinance No. (2025) 802, adopted October 21, 2025) · Raleigh City Code § 5-2047

Corpus is an independent public-information project, not the official City of Raleigh website. Stable reference: corpuslaw.us/code/3afbb834-c392-4141-9e57-b3b1028993c1

Sec. 5-2047. - THIRD-PARTY INSPECTIONS AND REPORTING SYSTEM.

(a) Inspections and Maintenance Required. The owner of the property where any device, equipment, alarm, system and any other feature is required for compliance of the provisions of this Article or is otherwise installed on the property shall cause maintenance, testing and inspections of all such devices, equipment, alarms, systems and features in accordance with this Code and applicable referenced standards and specified intervals. If following inspection and testing, any device, equipment, alarm, system and any other feature does not meet manufacture's specifications or fails to perform as intended, then it shall be repaired or replaced in accordance with subsection (e) below. Maintenance, testing and inspections shall include, without limitation, the following: Fire Protection Measure | N.C. Fire Code Reference | National Fire Protection Association Code Reference 1. Automatic Fire Sprinkler System | 901.6.1 & 901.6.2 | 25 2. Commercial Hood Cleaning | 609.3 | 96 3. Commercial Kitchen Hood System | 901.6.1 & 901.6.2 904.12.6.2 | 17A 4. Emergency Generator | 604.4 | 110 & 111 5. Fire Alarm System | 901.6.1 & 901.6.2 | 72 6. Fire Doors | 703.4 | 80 7. Fire Escape | 1031.2 8. Fire Pumps | 913.5 | 25 9. Foam System (including 5 yr test) | 901.6.1 & 901.6.2 | 25 10. Private Hydrant System | 507.5.2 & 507.5.3 | 25 11. Smoke Control System | 909.20 | 90 & 92B 12. Special Suppression System | 901.6.1 & 901.6.2 | 12, 12A, 750 & 2001 13. Spray Booth | 901.6.1 & 901.6.2 | 33 14. Standpipe (including 5 yr hydrostatic test) | 901.6.1 & 901.6.2 | 25 15. Emergency Responder Radio Coverage Systems | 510.6.1; 510.5.4 | 1221 Testing of all backflow prevention assemblies installed and maintained per NFPA-25 are regulated by the Department of Public Utilities pursuant to §8-2154. (b) Qualifications of Inspectors. Only qualified personnel shall make inspections or perform testing required by the current editions of the North Carolina Fire Prevention Code and the adopted provisions of technical codes. Qualified personnel shall include, but not be limited to: (1) Personnel who are factory-trained and certified for the type and brand of device, equipment, alarm, system, or feature being inspected or tested. (2) Personnel who are certified by a nationally recognized certification organization approved by the City. (3) Personnel who are registered, licensed or certified by North Carolina or the City of Raleigh to perform the required inspections and testing. (4) Personnel of the Fire Department. (c) Reporting of Inspections and Tests. Records of all installations, inspections, tests and maintenance required by §5-2047 shall be provided electronically to the City's designated electronic reporting system. Completed records shall be submitted no later than fifteen (15) days following the applicable installation, inspection, test and maintenance. The submitted report shall contain all information required by the City's designated electronic reporting system. The fee for any report filed using the electronic reporting system shall be as set forth in the City of Raleigh Fee Schedule. (d) Retention of Records. Records of all any device, equipment, alarm and system inspections, tests and maintenance required by the current editions of the North Carolina Fire Prevention Code and the adopted provisions of technical codes shall be maintained on the premises for a minimum of three (3) years following the date of any inspection, test and maintenance and shall be copied to the fire department and its contractors pursuant to either the provisions of the City Code or upon the request of the fire control official. (e) Repairs. If any device, equipment, alarm, system and any other feature fails its inspection or operational test, within thirty (30) days of such inspection or test or the property owner shall make all necessary repairs to make the item fully operational. Defective parts must be replaced with manufacturer approved parts. If repair is not possible, the item must be replaced with devices, equipment, alarms, systems and features in accordance with this Code and applicable referenced standards. Completed records shall be submitted no later than fifteen (15) days following the applicable maintenance, repair or replacement. The submitted report shall contain all information required by the City's designated electronic reporting system. The fee for any report filed using the electronic reporting system shall be as set forth in the City of Raleigh Fee Schedule. Additional inspections and testing may be required of the repaired or replaced device, equipment, alarm, system or other feature upon the request of the fire code official.

(Ord. No. 2015-492, §2, 10-7-15, eff. 10-12-15; Ord. No. 2020-101, §§1, 2, 6-15-20, eff. 7-1-20; Ord. No. 2021-258, §1, 7-6-21)

Ask a question about Raleigh law

Corpus searches the Raleigh sections it holds and shows the ones that match, with their citations. Free, no sign-in.