Mobile home stands.
Greenville Code of Ordinances § 5-283
in effectSec. 5-283. - Mobile home stands.
The area of the mobile home stand shall be improved to provide an adequate foundation for the placement and tie-down of the mobile home, thereby securing the superstructure against uplift, sliding, rotation and overturning.
(1) The mobile home stand shall not heave, shift or settle unevenly under the weight of the mobile home due to front action, inadequate drainage, vibration or other forces acting on the superstructure. Runways or slabs shall be constructed of either reinforced cement concrete or well-compacted gravel and bituminous concrete material.
(2) The mobile home stand shall be provided with anchors and tie-downs such as cast-in-place concrete "dead men" imbedded in concrete foundations or runways, screw augers, arrowhead anchors, or other devices securing the stability of the mobile home.
(3) Anchors and tie-downs shall be placed at least at each corner of the mobile home stand and each shall be able to sustain a minimum tensile strength of two thousand eight hundred (2,800) pounds.
(4) The foregoing requirements shall be subject to modification by the city and/or county engineers to ensure the most practical application of these requirements to the respective mobile home park.
(Ord. of 1-18-72, § V(5.11))
Source: City of Greenville, Mississippi, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/ms/greenville/codes/code_of_ordinances?nodeId=PTIICOOR_CH5LIBURE_ARTVIIMOHOPA_DIV2ENOPSPAC_S5-283MOHOSTFetched: 11/15/2026