§ 10-322 — Bufferyard Types
Code of Ordinances of the City of Tyler, Texas (September 2026: including amendments through September 9, 2026) · Tyler City Code § 10-322
Corpus is an independent public-information project, not the official City of Tyler website. Stable reference: corpuslaw.us/code/3c1c69a8-13db-4d7a-b4cc-31eb98263a8b
Sec. 10-322. Bufferyard Types
a. “Type A” Bufferyard 1. Applicability A “Type A” buffer yard is used to separate the following abutting districts a) single-family residential zoning districts from higher-density residential districts and b) all residential districts from light commercial, restricted professional office, and institutional districts. (Ord. No. 0-2012-38, 4/25/12) 2. Type A Bufferyard Composition A “Type A” buffer yard must consist of one of the following: (a) A 10-foot-wide planting area with an average of one tree of 6” DBH or larger at maturity per 50 feet or one evergreen shrub per 50 linear feet; [image omitted; see the official code] (b) A 7.5-foot-wide planting area with an average of two trees of 6” DBH or larger at maturityand two evergreen shrubs per 50 linear feet; or (Ord. No. 0-2009-19; 3/11/09) [image omitted; see the official code] (c) A 5-foot-wide planting area with an average of two trees of 6" DBH or larger at maturity and two shrubs of any type per 50 linear feet. (Ord. No. 0-2009-19; 3/11/09) [image omitted; see the official code] (d) A 5-foot-wide planting area with an average of one medium or large evergreen tree of 6" DBH or larger at a maturity for each 50 linear feet of buffer yard spaced no more than 35 feet apart to provide additional screening above a required solid six-foot screening wall constructed of brick, stone, reinforced concrete, or other similar two-sided masonry materials. Wood (redwood, cedar, or other preservative pressure treated wood), may be used as long as a continuous masonry wall (one foot height minimum) on a concrete footer is installed. The wooden panels must be separated by masonry columns spaced no further apart than 20 feet. (Ord. No. 0-2010-119; 11/10/10) [image omitted; see the official code] b. “Type B” Bufferyard 1. Applicability A Type "B" bufferyard is used to separate a) general commercial (C-2), planned commercial (PCD) and high-intensity planned mixed zoning districts (PMXD-2) from any other nonresidential districts; and b) commercial and office districts from any residential district. (Ord. No. 0-2009-19; 3/11/09) 2. Type B Bufferyard Composition A Type B bufferyard must consist of one of the following: (a) A 20-foot-wide planting area with an average of one tree of 6" DBH or larger at maturity per 50 linear feet spaced no more than 35 feet apart; [image omitted; see the official code] (b) A 15-foot-wide planting area with an average of one tree of 6" DBH or larger at maturity and one shrub per 35 linear feet; or [image omitted; see the official code] (c) A 10-foot-wide planting area with an average of two trees of 6" DBH or larter at maturity and two shrubs per 35 linear feet. [image omitted; see the official code] (d) A 10-foot-wide planning area with an average of one medium or large evergreen tree of 6" DBH or larger at maturity for each 50 linear feet of buffer yard, spaced no more than 35 feet apart to provide additional screening above a required solid six-foot screening wall constructed of brick, stone, reinforced concrete, or other similar two-sided masonry materials. Wood (redwood, cedar, or other preservative pressure treated wood), may be used as long as a continuous masonry wall (one foot height minimum) on a concrete footer is installed. The wooden panels must be separated by masonry columns spaced no further apart than 20 feet. (Ord. No. 0-2010-119; 11/10/10) [image omitted; see the official code] c. “Type C” Bufferyard 1. Applicability A Type C bufferyard is used to separate industrial districts (M-1 and M-2) from all other zoning districts. 2. Type C Bufferyard Composition A “Type C” buffer yard must consist of one of the following options: (a) A 10-foot-wide planting area with an average of two evergreen trees of 6" DBH or larger at maturity for each 50 linear feet of buffer yard, spaced no more than 35 feet apart to provide additional screening above a required solid six-foot screening wall constructed of brick, stone, reinforced concrete, wood, or other similar two-sided masonry materials; or [image omitted; see the official code] (b) A 30-foot-wide planting area with a berm at least three feet tall and minimum 4:1 side slope, with an average of four shrubs at the top of the berm per 50 linear feet. [image omitted; see the official code] (c) A 50-foot-wide buffer area with existing tree canopy equal to at least one tree per 50'. (Ord. No. 0-2010-20, 3/10/10)
Ask a question about Tyler law
Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.