SF-D (Single-Family - Downtown) district.
Round Rock Zoning and Development Code, art. II, § 2-17
in effectSec. 2-17. - SF-D (Single-Family - Downtown) district.
(a) Purpose. To establish and preserve areas of land use primarily devoted to low density residential development. This district provides for traditional residential development and includes standards to reinforce the scale and design of an established residential neighborhood with numerous historic structures.
(b) Permitted uses. Uses permitted in the SF-D district may be found in Sec. 2-25.
(c) Lot and building dimensional standards. Property and buildings in the SF-D district shall conform to the standards found in Sec. 2-26, with the following supplementary notes:
(1) The front setback from the street shall be the same as adjacent buildings +/- 5 feet. If the two setbacks on either side of the subject property are greater than 10 feet different from one another, the owner of the subject property may choose which adjacent property to use to establish the contextual setback.
(2) All portions of a garage and garage doors shall be set back a minimum of 5 feet from the front elevation of the main structure.
(3) Floor to floor heights shall be the same as adjacent structures in a block.
(4) Fences may be up to eight (8) feet in height to accommodate topographical changes, as approved by the zoning administrator.
(d) Supplementary development standards. In addition to the standards found in chapter 8 of this Code, the following regulations apply to the SF-D district:
(1) Parking requirements.
a. Parking and access shall be permitted only on improved surfaces.
b. On-site parking is not required for single-family dwelling units, but is required for the following uses:
1. A bed and breakfast shall provide one on-site parking space for each guest room.
2. Other uses shall provide on-site parking in accordance with chapter 8, article VI.
c. Garages shall not be required. When a garage is constructed, it shall be complementary in materials and design to the primary structure on the lot.
d. Where an alley exists and is clear of man-made obstructions, new garages shall be oriented toward the alley. If no alley exists, new garages shall be oriented toward an available secondary frontage. If the garage is oriented toward the secondary frontage, the facade that faces the primary frontage shall include articulation such as windows.
e. A driveway constructed to access a new garage shall be no wider than 18 feet within the setback, and no wider than the garage at any point.
f. No single garage door facing a public street shall exceed 18 feet in width.
g. On-site parking placement.
1. Where access is available from an alley or secondary frontage, parking shall be located at the rear of the property behind the principal structure.
2. If a property has an existing driveway, it may be utilized to meet any on-site parking requirement but may not be expanded in the street yard to accommodate additional parking. Slight modifications may be made to the existing driveway to access additional parking located at the rear of the structure. A driveway shall be no wider than 18 feet within the required front or side setback.
(2) Exterior wall finish. Day-Glo, luminescent, neon, or similar types of color finishes are prohibited.
(3) Height, massing and placement requirements.
a. Front facades of the primary structure shall be parallel to the street.
b. The scale of a new building or addition shall reflect the scale of adjacent buildings.
c. The scale and placement of façade elements such as doors, windows, porches, columns, and other architectural features shall be similar to surrounding buildings.
(4) Additions to the primary structure on a lot. Additions shall be compatible and secondary in size, design, proportion, and detail to the primary residential structure on a lot.
(5) Roofs. Roof pitch shall be a minimum of 4:12.
(6) Lot fencing.
a. Fences shall be constructed of the following materials: brick, stone, wrought iron, or wood. Other decorative masonry materials, reinforced concrete, or wrought iron equivalents may be approved by the zoning administrator.
b. Fence posts shall be constructed of wood, rust-resistant metal parts, concrete-based masonry or concrete pillars.
c. Fence posts and fence panels for non-wood fences shall be capped.
d. All fences shall provide a finished face to all public rights-of-way.
e. Fences shall not conflict with sight triangles at street intersections or obstruct views from adjacent driveways.
(7) Fence requirements and maintenance.
a. These regulations shall apply only to fences that:
1. Face a public street, a public park, a public recreation facility, a school, a library, or a government office; or
2. Are adjacent to a public drainage facility and are visible from a public street.
b. Fences are not required in the SF-D district. However, the owners of fences subject to this section shall maintain fences in a safe condition and in good repair, with all components free from deterioration, dilapidation, rot, rust, loosening, or leaning. Fences shall be able to withstand the wind load for which they were designed. In addition, the following regulations shall apply:
1. A fence shall not be out of vertical alignment more than one (1) foot from the vertical measured at the top of the fence, with the exception of fencing measuring four (4) feet or less in height, which vertical alignment shall not be more than six (6) inches from the vertical measured at the top of the fence.
2. A fence shall not have any broken, loose, damaged or rotted components having a combined total area of twenty (20) square feet or more, said area being calculated over any 50 contiguous linear foot section of fence.
3. A fence shall not have any missing posts, panels, or pickets.
4. Painted fence components shall be regularly maintained to prevent rusting, peeling, or blistering surfaces.
5. If the city determines a fence is unsafe, dilapidated or a public nuisance, or otherwise in violation of this chapter, it shall be repaired, replaced or demolished within 60 days upon first notification of non-compliance. Repairs shall be made with materials comparable in composition, color, size, shape and quality to the original fence. Products not intended to be used as fencing are prohibited from being used in the repair of a fence.
(8) Mechanical equipment and trash receptacles for nonresidential uses.
a. Roof-mounted equipment shall be set back from the edges of roofs and screened so as not to be visible from public view.
b. No mechanical or service areas shall be placed in the street yard.
c. Trash receptacles shall be screened from the street and pedestrian areas with fencing or appropriate height landscaping.
(Ord. No. O-2019-0204, § III, 5-9-2019; Ord. No. O-2019-0463, § V, 11-26-2019)
Source: City of Round Rock, Texas, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/tx/round_rock/codes/code_of_ordinances?nodeId=PTIIIZODECO_CH2ZODIUSRE_ARTIIREDI_S2-17SIMIOWDIFetched: 11/16/2026