§146.0202 Alterations, Additions, Relocations, and Conversions of Existing Wiring
(a) Additions, extensions, alterations, or removal of existing wiring installations shall be made in compliance with the provisions of this article.
(1) Where additions, alterations, or extensions of a wiring installation are proposed in cases where this article requires a metallic wiring method, and the existing installation was lawfully installed according to any other applicable ordinance, code, or order and is not unsafe in the opinion of the Building Official, the existing installation need not be replaced.
(2) Existing electrical systems may be used in connection with alterations or repairs if such electrical systems have been properly maintained and were installed in accordance with the applicable laws in effect at the time of installation. Any electrical system shall be deemed to have conformed with applicable law in effect at the time of installation and to have been maintained in good condition if currently in a good and safe condition and working properly.
(3) Where the electrical system, including but not limited to interior branch circuit wiring, is upgraded at the record owner’s initiative, the receptacle spacing requirements of the California Electrical Code, Article 210, Section 52, shall apply.
(b) Electrical systems in relocated buildings shall comply with the provisions of this article except for the following:
(1) Existing receptacle outlets located in rooms within relocated dwellings shall comply with applicable codes adopted at the time of original construction.
(2) The spacing of new receptacle outlets shall comply with Section 210.52(A)(1) of the California Electrical Code.
(3) Existing receptacle outlets which are not grounded shall comply with Section 406.4(D)(2) of the California Electrical Code.
(c) In an overhead to underground conversion district, the existing electrical service shall be replaced or repaired if any one of the following conditions exists:
(1) When the electrical service equipment is not dead-front operated;
(2) When the electrical service equipment is not readily accessible;
(3) When the electrical service equipment is not grounded; or
(4) When the electrical service equipment is not adequate to carry the actual load.