§ 14E-10-010 — Informative annexes
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14E-10-010
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/3f17c15d-418e-4720-87f6-90f17db41c54
14E-10-010 Informative annexes.
These informative annexes are not part of the enforceable requirements of this Code, but are included for information purposes only. 1. Informative Annex A of NFPA 70 is adopted by reference without modification. 2. Informative Annex B of NFPA 70 is adopted by reference without modification. 3. The following tables are adopted as Informative Annex C, entitled "Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size": Table C.1 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Electrical Metallic Tubing (EMT) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 10 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 3/4 8 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 6 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 3 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 300 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 3-1/2 400 | 1-1/4 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - 600 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - 700 | 1-1/4 | 2-1/2 | 3 | 3-1/2 | 4 | 4 | - - - | - - - | - - - 750 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 800 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 900 | 1-1/2 | 3 | 3 | 4 | - - - | - - - | - - - | - - - | - - - 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - Table C.1(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Electrical Metallic Tubing (EMT) Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 3/4 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 1 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 | 2-1/2 2/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 4/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 250 | 3/4 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 300 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 350 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 400 | 1 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 3-1/2 500 | 1-1/4 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | 4 600 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | - - - | - - - 700 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - 750 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - 1,000 | 1-1/2 | 3 | 3 | 4 | - - - | - - - | - - - | - - - | - - - Table C.3 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Flexible Metal Conduit (FMC) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | – | – | – | – | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | – | – | – | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 10 | – | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 8 | – | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 6 | – | 1/2 | 3/4 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 2 | 2 | 2 3 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 2 | 2 | 2 | 2 2 | 1/2 | 1 | 1 | 1-1/4 | 2 | 2 | 2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 2 | 2 | 2 | 2 | 2 | 2-1/2 1/0 | 1/2 | 1-1/4 | 2 | 2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/2 | 2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 3/4 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 350 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 400 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - 500 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - 600 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 700 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 750 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 800 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 900 | 2 | 3-1/2 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 1,000 | 2 | 3-1/2 | 3-1/2 | - - - | - - - | - - - | - - - | - - - | - - - Table C.3(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Flexible Metal Conduit (FMC) Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | – | 1/2 | 1/2 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | – | 3/4 | 3/4 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 2 | 2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 2 | 2 | 2 | 2 1 | 1/2 | 1 | 1-1/4 | 2 | 2 | 2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 2 | 2 | 2 | 2 | 2 | 2-1/2 2/0 | 1/2 | 1-1/4 | 2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | 4 | - - - 600 | 1-1/4 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | - - - | - - - | - - - 700 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - | - - - 750 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 1,000 | 2 | 3-1/2 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - Table C.4 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Intermediate Metal Conduit (IMC) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 10 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 8 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 6 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 3/4 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 3 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 1-1/2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 1 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2 | 2-1/2 2/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | - - - | - - - 600 | 1-1/4 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | - - - | - - - | - - - 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 750 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 800 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 900 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - Table C.4(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Intermediate Metal Conduit (IMC) Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 4 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 1 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 1/0 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2 2/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 4/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 250 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 300 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 400 | 1 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 500 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 600 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - 700 | 1-1/4 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | - - - | - - - | - - - 750 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - | - - - 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - Table C.8 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Liquidtight Flexible Metal Conduit (LFMC) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | – | – | – | – | – | – | – | – | 1/2 12 | – | – | – | – | – | 1/2 | 1/2 | 1/2 | 1/2 10 | – | – | – | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 8 | – | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 6 | – | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | – | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 3 | – | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 2 | – | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 3/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 350 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 400 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - 500 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - 600 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - | - - - 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 750 | 1-1/2 | 3 | 3 | 4 | 4 | - - - | - - - | - - - | - - - 800 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 900 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - 1,000 | 2 | 3-1/2 | 3-1/2 | - - - | - - - | - - - | - - - | - - - | - - - Table C.8(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Liquidtight Flexible Metal Conduit (LFMC) Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | – | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | – | 3/4 | 3/4 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 2 | – | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 1 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 2/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 4/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 | 3 250 | 3/4 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | - - - 600 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | - - - | - - - | - - - 750 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | - - - | - - - | - - - | - - - | - - - Table C.9 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Rigid Metal Conduit (RMC) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 10 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 8 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 6 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 3 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 3/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 350 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 5 500 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 600 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 | 5 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 750 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 800 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 | 6 900 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | 6 1,000 | 1-1/2 | 3-1/2 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | - - - Table C.9(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Rigid Metal Conduit (RMC) Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 4 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 1 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 2/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 4/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 250 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 600 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 | 5 750 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 5 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | 6 Table C.10 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Rigid PVC Conduit, Schedule 80 Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 10 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 8 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 6 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 4 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 3 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 2 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 1 | 3/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 1/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 3/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 4/0 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 250 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 300 | 1-1/4 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 350 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 400 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | 5 | 5 500 | 1-1/4 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | 5 | 5 | 5 600 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 700 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 | 6 750 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 | 6 800 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | 6 900 | 2 | 3-1/2 | 3-1/2 | 5 | 5 | 5 | 6 | 6 | - - - 1,000 | 2 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | - - - | - - - Table C.10(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Rigid PVC Conduit, Schedule 80 Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 4 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 1-1/2 2 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 | 2-1/2 1/0 | 3/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 3/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 1 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 350 | 1-1/4 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 400 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 500 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 600 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 | 5 700 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 750 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 1,000 | 2 | 3-1/2 | 3-1/2 | 5 | 5 | 6 | 6 | 6 | - - - Table C.11 – Number of The Same Size Conductors in Trade Size of Conduit or Tubing Rigid PVC Conduit, Schedule 40 Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 14 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 12 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 10 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 3/4 8 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1 6 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 3 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 1 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 | 2-1/2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 3/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 4/0 | 3/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 350 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 400 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 500 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 4 | 5 | 5 600 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 5 700 | 1-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 750 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 | 6 800 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 | 6 900 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | 6 1,000 | 2 | 3-1/2 | 3-1/2 | 5 | 5 | 5 | 6 | 6 | - - - Table C.11(A) – Number of The Same Size Compact Stranded Conductors in Trade Size of Conduit or Tubing Rigid PVC Conduit, Schedule 40 Conductor Types THHN (Based on Table 1, Chapter 9) | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 100% | 80% | 70% 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 6 | 1/2 | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 | 1-1/4 | 1-1/4 4 | 1/2 | 3/4 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/2 2 | 1/2 | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 1-1/2 | 2 1 | 1/2 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 1/0 | 1/2 | 1-1/4 | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2 | 2-1/2 2/0 | 3/4 | 1-1/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 3/0 | 3/4 | 1-1/4 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 4/0 | 3/4 | 1-1/2 | 1-1/2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 250 | 1 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 300 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3 | 3-1/2 | 3-1/2 350 | 1 | 2 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 400 | 1 | 2 | 2-1/2 | 3 | 3 | 3-1/2 | 3-1/2 | 4 | 4 500 | 1-1/4 | 2-1/2 | 2-1/2 | 3 | 3-1/2 | 3-1/2 | 4 | 4 | 5 600 | 1-1/4 | 2-1/2 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 700 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 5 750 | 1-1/4 | 3 | 3 | 3-1/2 | 4 | 5 | 5 | 5 | 6 1,000 | 1-1/2 | 3 | 3-1/2 | 4 | 5 | 5 | 6 | 6 | 6 4. Informative Annex D of NFPA 70 is adopted by reference without modification. 5. Informative Annex F of NFPA 70 is adopted by reference without modification. 6. Informative Annex G of NFPA 70 is adopted by reference without modification. 7. Informative Annex I of NFPA 70 is adopted by reference without modification.
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
