Number of sanitary facilities.
Omaha Municipal Code § 54-121
in effectSec. 54-121. - Number of sanitary facilities.
Assuming equal distribution of male and female bathers, toilet and shower facilities shall be provided on the basis of the following fixture schedule. Fixture schedules should be increased for swimming pools at schools or similar locations where bather loads may reach peaks due to schedules of use. Sanitary facilities and showers shall be designed and sized to accommodate the age groups anticipated.
Number | WC Male | UR Male | Lav Male | Showers Male | WC Female | Lav Female | Showers Female | Drinking Fountain
1—25 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0
26—50 | 1 | 1 | 1 | 2 | 2 | 1 | 2 | 1
51—75 | 2 | 1 | 1 | 3 | 3 | 2 | 3 | 1
76—100 | 2 | 1 | 2 | 4 | 4 | 2 | 4 | 1
101—200 | 3 | 1 | 2 | 5 | 5 | 3 | 5 | 2
201—300 | 3 | 2 | 3 | 6 | 6 | 3 | 6 | 3
Add one water closet or one urinal for each additional 150 males or fraction thereof. Urinals may be substituted for water closets provided the number of urinals shall not be more than twice the number of water closets.
Add one lavatory for each additional 300 males or fraction thereof.
Add one water closet for each additional 150 females or fraction thereof.
Add one lavatory for each additional 300 females or fraction thereof.
_____
(Code 1980, § 54-121; Ord. No. 37382, § 37, 5-23-06)