Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
40 C.F.R. § 408.222
in effectExcept as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic
Effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of seafood)
TSS2212
Oil and grease9.93.9
pH(
1)(
1)
English units (pounds per 1,000 lb of seafood)
TSS2212
Oil and grease9.93.9
pH(
1)(
1)
1 Within the range 6.0 to 9.0.