§ 49-62 — Backflow prevention assemblies required

Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 49-62

Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/40124865-c365-4a72-987c-ba3139209094

Sec. 49-62. - Backflow prevention assemblies required.

(a) When any of the following items or activities are present or conducted on premises served by the public potable water supply system, a potential hazard to the public potable water supply system shall be presumed and a backflow prevention assembly, of the type specified for that item or activity herein, must be in place at each service connection for that premises. (1) Aircraft and missile plants: RP. (2) Animal clinics and animal grooming shops: RP. (3) Any premises where a cross-connection is maintained: RP. (4) Automotive repair with steam cleaner, acid cleaning equipment, or solvent facilities: RP. (5) Auxiliary water systems: RP. (6) Beauty shops: RP. (7) Bottling plants, beverage or chemical: RP. (8) Breweries: RP. (9) Buildings that have plumbing or fixtures connected to plumbing that are greater than thirty-four (34) feet in height maximum from service connection: RP. (10) Buildings with house pumps and/or potable water storage tank: RP. (11) Buildings with landscape fountains, ponds, or baptismal tanks: RP. (12) Buildings with sewage ejectors: RP. (13) Buildings used for commercial mini-warehouses or industrial uses where one (1) service connection supplies more than one (1) tenant or occupant of the building: RP. (14) Canneries, packing houses, and reduction plants: RP. (15) Car wash facilities: RP. (16) Cooling towers, boilers, chillers and other heating and cooling systems utilizing potable water: RP. (17) Chemical plants: RP. (18) Chemically treated potable or nonpotable water systems: RP. (19) Civil works (government-owned or- operated facilities not open for inspection by the Water Resources Division): RP. (20) Commercial laundries: RP. (21) Dairies and cold storage plants: RP. (22) Dye works: RP. (23) Film processing laboratories, facilities, or equipment: RP. (24) Fire systems, as classified by the American Water Works Association (AWWA) Manual M14, 2nd edition: a. In accordance with section 49-64(a), Class 1, Class 2: DC. b. Class 3, all systems: DC c. Classes 4, 5 and 6, all systems: RP. (25) Fire systems. Where backflow protection is required on the industrial/domestic service connection that is located on the same premises, both service connections will have adequate backflow protection for the highest degree of hazard affecting either system. (26) Food processing plants: RP. (27) Educational Institutions, Public and Private: RP. (28) Holding tank disposal stations: RP. (29) Hospitals and mortuaries: RP. (30) Hydrant meters connecting to the public potable water supply system to be used for irrigation or construction water: RP or air gap. (31) Irrigation system: a. Premises where nonpotable water is used for irrigation: RP. b. Premises using potable water with nonpotable water piping: RP. c. Premises having a system served by more than one (1) service connection (looped system): RP. d. Landscape irrigation systems: PVB or RP. (32) Laboratories using toxic materials: RP. (33) Manufacturing, processing, and fabricating plants using toxic or nontoxic materials: RP. (34) Master metered apartments, condos and townhouses with more than two units per meter: RP. (35) Medical and dental buildings, sanitariums, rest and convalescent homes engaged in the diagnosis, care or treatment of human illness: RP. (36) Mobile home parks served by master meter: RP. (37) Motion picture studios: RP. (38) Multiple services-interconnected: RP. (39) Oil and gas production facilities: RP. (40) Paper and paper product production facilities: RP. (41) Plating plants: RP. (42) Portable insecticide and herbicide spray tanks: RP or air gap. (43) Post mix drink machines: RP. (44) Power plants: RP. (45) Public swimming pools with self-levelers or automatic fillers: PVB or RP. (46) Radioactive materials processing facilities: RP. (47) Restaurants: RP. (48) Restricted, classified, or other closed facilities: RP. (49) Rubber plants: RP. (50) Sand and gravel plants: RP. (51) Sewage and storm drainage facilities: RP. (52) Shopping centers served by master meters: RP. (53) Waterfront facilities, piers, docks, dockside facilities and boat marinas: RP. (54) Water trucks, water tanks or hydraulic sewer cleaning equipment: RP or air gap. (b) When two (2) or more of the items or activities listed above are present or conducted on the same premises and served by the same service connection, the most restrictive backflow preventer required for any of the items or activities present or conducted on the premises shall be required to be utilized or installed at the service connection. The order of most restrictive to least restrictive backflow preventers shall be as follows: (1) Air gap (most restrictive); (2) Reduced pressure principle assembly (RP); (3) Double check valve assembly (DC); (4) Pressure vacuum breaker assembly (PVB) (least restrictive). (c) If any owner or account holder fails to install a device or perform any action required by this section within ninety (90) days for install of a device or thirty (30) days to perform a necessary action of receiving written notice from the Water Resources Division of the need to do so, the Division may either: (1) If feasible, install the required device or perform any necessary action on behalf of the owner or account holder and include the cost of such installation on the next regularly scheduled invoice to the account holder, or (2) Discontinue water service as outlined in Section 49-66 to the property until the required device is installed. (3) Once a customer is designated as non-compliant, the then current water rate per 1,000 gallons will be adjusted by one hundred fifty (150) percent for one full billing cycle or until the customer is deemed compliant, whichever comes later. (d) The notice sent to the owner or account holder in accordance with subsection (c) shall include an advisory from the Division that the Division may install an appropriate device at the owner or account holder's expense or that the service may be discontinued if the required device is not installed.

Ask a question about Scottsdale law

Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.